DOI:
10.1039/C5RA14443D
(Paper)
RSC Adv., 2015,
5, 76296-76301
Proton donor modulating ESIPT-based fluorescent probes for highly sensitive and selective detection of Cu2+†
Received
21st July 2015
, Accepted 29th August 2015
First published on 1st September 2015
Abstract
Two novel ESIPT-based fluorescent probes, N-(2-(1-(p-tolyl)-1H-phenenanthro[9,10-d]imidazol-2-yl)phenyl) picolinamide (Pi-A) and 2-(1-(p-tolyl)-1H-phenanthro[9,10-d]imidazol-2-yl)phenylpicolinate (Pi-E), were designed and synthesized. The favorable features of the proposed probes included excellent water solubility, wide pH range, high selectivity and sensitivity to Cu2+. Interestingly, the difference in the linker of the probe molecules led to a radical change in the fluorescent response of the probes to Cu2+. Pi-A showed fluorescence turn-off towards Cu2+ with a detection limit of 1.6 × 10−9 M and Pi-E showed fluorescence turn-on towards Cu2+ with a detection limit of 1.8 × 10−8 M in the same condition. The Cu2+ recognition mechanisms of the probes were investigated by Job's plot analyses, NMR and ESI-MS spectroscopy experiments. Moreover, our experiments also showed that the probes are of excellent cell permeability and are capable of imaging Cu2+ within living cells.
Introduction
Copper(II) is one of the necessary microelements in the human body and plays crucial roles in many physiological processes.1 It is also known to be a catalytic cofactor for many metalloenzymes and proteins in organisms.2 However, the alteration of intracellular Cu2+ homeostasis is implicated in various diseases including prion disorders, Parkinson's, and other ailments.3,4 Therefore, the development of efficient and convenient methods for sensing Cu2+ in biological samples is highly valuable to understand its physiological functions and pathological events. Several traditional analytical methods5–7 like inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and atomic absorption spectrometry (AAS) have been reported to detect Cu2+. However, these methods involve complicated sample preparation and require expensive and sophisticated instrumentation. The fluorescent probes have been considered as ideal tools that can monitor and image trace amounts of metal ions in live cells or tissues due to its high sensitivity, operational simplicity, and real-time and nondestructive imaging properties.8,9
Up to now, various fluorescent probes for Cu2+ have been designed and synthesized by employing different mechanisms such as coordination to receptors,10–14 Cu2+-mediated hydrolysis of amides and esters,15–19 oxidation of phenothiazine, phenol and dihydrorosamine.20–23 However, many of them still have drawbacks. For instance, some were only utilized in solutions with large amounts of organic solvents or a narrow pH range,16,17,24–26 which would limit their further applications in biological systems. Some probe involved complicated synthetic procedures.10,11 In particular, some suffered from incomplete selectivity20,27–29 over the competing metal ions such as Fe3+, Co2+, Ni2+ and Hg2+ due to the similar ionic radius and chemical properties. Thus, it is still necessary to devise new simple-structured fluorescent probes for Cu2+ detection in vitro and in vivo.
Recently, excited-state intramolecular proton transfer (ESIPT) dyes have attracted much attention in probe design due to their intriguing photophysical properties, such as the ultrafast ESIPT reaction and the large Stokes shift.30,31 Among various ESIPT dyes, 2-(2-hydroxyphenyl)-9,10-phenanthro imidazoles (HPI) are a new class of π-expanded imidazole derivatives, and have been studied for their synthesis and optical spectroscopic properties.32–35 As the fluorophore, HPI seem to be especially suitable for constructing fluorescent probes for detection of analytes due to their ease of synthetic modification and fluorescence modulation by functionalization of the hydroxyl groups, and large Stokes shift.36,37 Moreover, their analogues bearing an acidic NH group as proton donor of the intramolecular H-bond system show higher quantum yield and more active ESIPT process compared with HPI molecules.33,38,39 Given the similarities and differences in the ESIPT mechanism between O–H and N–H H-bonding systems, it is possible to obtain more ESIPT-fluorescent probes by adjustment of the proton donor group (typically an OH or NH2 group). Herein, we synthesized a pair of Cu2+ fluorescent probes by protection of the amine group and the hydroxyl in compound 1 and 2 with a 2-pyridinecarbonyl group, respectively (Scheme 1). The linker between the signal group and recognition union of Cu2+ ions was explored. Interestingly, using –NH group as the linker, the probe Pi-A exhibited a fluorescent “turn-off” behavior toward Cu2+. While O atom was used as the linker, the probe Pi-E showed a fluorescent “turn-on” behavior to Cu2+ (Scheme 2). The result showed that both probes have many advantages including good water solubility, wide pH range, high sensitivity and selectivity to Cu2+. They were successfully used in imaging of Cu2+ in living cells.
 |
| | Scheme 1 Synthesis route of Pi-A and Pi-E. | |
 |
| | Scheme 2 Proposed detection mechanism of Pi-A and Pi-E with Cu2+. | |
Experimental section
Reagents and apparatus
Salicylaldehyde, picolinic acid, o-nitrobenzaldehyde and phenanthrenequinone were purchased from TCI (Shanghai) Development Co., Ltd. Dimethyl sulfoxide (chromatographic grade) was gained from Merck Chemicals Co., Ltd. Other analytes were obtained from Aladdin Chemistry Co., Ltd. Silica gel plates (60F-254) and silica gels (mesh 300–400) were used for thin layer chromatography analyses and column chromatography, respectively. UV-vis absorption spectra were collected on a UV2450 spectrophotometer (Shimadzu Co., Japan). Fluorescence spectra were recorded on a Hitachi F-4500 spectrophotometer (Hitachi Ltd, Japan). 1H NMR and 13C NMR spectra were obtained with tetramethyl silane (TMS) as the internal standard on a Bruker AVB-500 spectrometer. Mass analyses were performed using an API 4000 QTRAP LC/MS/MS system with ESI Ion Source (AB SCIEX Co., USA). All pH measurements were carried out on a Model pHS-3C pH meter (Shanghai, China). The probe Pi-A and Pi-E were characterized by 1H NMR, 13C NMR and ESI-MS (Fig. S1–S6†).
Synthesis of probe Pi-A
Compound 1 and compound 2 were synthesized according to the reported methods.40 Pi-A as a “turn-off” probe for Cu2+ was synthesized. The synthesis route of the probe was shown in Scheme 1. Picolinic acid (1.23 g, 10.00 mmol) was dissolved in SOCl2 (20 mL), and the reaction mixture was refluxed for 5 h under N2 atmosphere. After removing the excess SOCl2, the obtained oily liquid was dissolved in CH2Cl2 (10 mL) and cooled in the ice-water bath. Then, the corresponding solution was slowly added into CH2Cl2 solution (30 mL) containing compound 1 (0.50 g, 1.25 mmol) and triethylamine (2.54 g, 25.08 mmol). After stirring for 8 h, the reaction mixture was washed with water (100 mL). Subsequently, the organic layer was separated, dried with anhydrous Na2SO4, filtered, and concentrated. The crude product was purified by silica gel column chromatography (15
:
1, petroleum ether
:
ethyl acetate, v/v) to give probe Pi-A as a yellow solid (0.39 g, 61% yield). 1H NMR (500 MHz, CDCl3): δ 13.50 (s, 1H), 9.22 (d, J = 7.5 Hz, 1H), 8.84 (d, J = 8.3 Hz, 1H), 8.79 (d, J = 8.4 Hz, 1H), 8.75 (d, J = 8.4 Hz, 1H), 8.55 (d, J = 4.3 Hz, 1H), 8.29 (d, J = 7.8 Hz, 1H), 7.91–7.79 (m, 2H), 7.72 (t, J = 7.1 Hz, 1H), 7.52 (ddd, J = 8.3, 6.0, 2.1 Hz, 1H), 7.41–7.34 (m, 6H), 7.29 (dd, J = 10.2, 4.7 Hz, 2H), 7.08 (dd, J = 7.8, 1.1 Hz, 1H), 6.86 (t, J = 7.5 Hz, 1H), 2.53 (s, 3H). 13C NMR (126 MHz, CDCl3): δ 163.28, 150.80, 148.44, 147.94, 139.94, 137.99, 137.17, 136.82, 135.76, 130.73, 129.71, 129.68, 129.43, 128.83, 128.52, 127.72, 127.14, 126.34, 126.08, 125.75, 125.04, 124.07, 123.23, 123.12, 122.60, 122.50, 121.67, 121.18, 118.91, 21.42. MS (EI) m/z: 504.40 (M+).
Synthesis of probe Pi-E
Pi-E was synthesized following the route showed in Scheme 1. Picolinic acid (1.23 g, 10.00 mmol) was dissolved in SOCl2 (20 mL). The reaction mixture was refluxed for 5 h under N2 atmosphere and then the volatiles were evaporated under reduced pressure. The residue dissolved in CH2Cl2 (10 mL), and the resultant solution was added dropwise to the solution of compound 2 (0.50 g, 1.25 mmol) and triethylamine (2.54 g, 25.08 mmol) in CH2Cl2 (20 mL). The mixture was stirred at room temperature for 10 h. Then, the solvent was removed by rotary evaporation. The residue was purified by silica gel column chromatography (5
:
1, petroleum ether
:
ethyl acetate, v/v) to afford probe Pi-E as a brown solid (0.47 g, 75% yield). 1H NMR (500 MHz, CDCl3): δ 8.70 (t, J = 7.1 Hz, 1H), 8.61 (d, J = 7.7 Hz, 1H), 8.48 (dd, J = 9.2, 6.0 Hz, 2H), 8.34 (d, J = 2.0 Hz, 1H), 7.61–7.55 (m, 2H), 7.54–7.45 (m, 3H), 7.44–7.36 (m, 2H), 7.33 (dd, J = 5.3, 2.6 Hz, 3H), 7.30–7.24 (m, 3H), 7.22 (dd, J = 8.9, 7.6 Hz, 1H), 7.12 (t, J = 7.5 Hz, 1H), 2.50 (s, 3H). 13C NMR (126 MHz, CDCl3): δ 163.51, 150.14, 149.95, 147.46, 146.80, 139.64, 137.13, 136.97, 135.22, 131.64, 130.46, 130.34, 129.15, 128.71, 128.11, 127.48, 127.12, 127.01, 126.90, 126.22, 126.03, 125.45, 125.31, 124.91, 123.92, 123.61, 123.10, 123.03, 122.94, 122.43, 121.19, 21.45. MS (EI) m/z: 505.36 (M+).
Spectroscopic measurements
Stock solutions of metal ions (10.0 mM) including CuCl2·2H2O, Pb(NO3)2, NaCl, CaCl2·2H2O, NiCl2·6H2O, MnCl2·4H2O, AgNO3, CuCl, FeCl2·4H2O, CdCl2·2.5H2O, MgCl2·6H2O, ZnCl2, CoCl2·6H2O, BaCl2·2H2O, Fe(NO3)3·9H2O, and HgCl2 were prepared in deionised water. Stock solutions of Pi-A or Pi-E (1.0 mM) were prepared in DMSO. These stock solutions were further diluted to required concentration for measurement. NaAc–HAc and Tris-HCl buffer solutions (10.0 mM) were prepared for pH 4.0–6.0 and 7.0–10.0, respectively. Test solutions were prepared as follows: 40 μL of Pi-A or Pi-E solution (0.5 mM) and proper amounts of Cu2+ solution were added into a test tube, and the final volume was adjusted to 2 mL with Tris-HCl buffer solution. After the solutions were incubated at room temperature for 30 min, absorption and fluorescence spectra were measured.
Cell culture and imaging
HeLa cells were grown in culture media (Dulbecco's modified Eagle's medium containing 10% fetal bovine serum, 1% penicillin and 1% streptomycin) at 37 °C in a humidified incubator with 5% CO2. Before the experiments, the cells were seeded in 96-well plates and allowed to adhere for 24 h. For fluorescence imaging, the cells were treated within 10 μM probes (Pi-A or Pi-E) in culture media for 30 min at 37 °C. After washing with PBS buffer three times to remove the remaining probes, the cells were further incubated with different concentration of CuCl2 (0, 10 μM) for 30 min at 37 °C. Subsequently, the fluorescence images were collected with an inverted fluorescent microscope (Nikon, Eclipse Ti-S).
Results and discussion
Optical response of Pi-A and Pi-E to Cu2+
In the UV-vis absorption spectra, Pi-A and Pi-E exhibited a maximum absorption peak at 272 nm and 258 nm, respectively, which are attributed to the conjugated π-electron systems21,41 (Fig. S7†). The fluorescence responses of Pi-A and Pi-E toward Cu2+ were investigated under the identical conditions. As shown in Fig. 1, Pi-A and Pi-E present strong and very weak fluorescence respectively. The addition of Cu2+ caused remarkable changes in the fluorescence spectra of the probes. Dramatically, Pi-A exhibited a 158-fold fluorescence turn-off response toward Cu2+, whereas Pi-E displayed a 12-fold fluorescence turn-on response to Cu2+. In addition, fluorescence spectra of Pi-E–Cu2+ were compared with that of standard compound 2 in DMSO with different water content. Although the enol or keto form emission of compound 2 was effected by water content in solutions, the spectra of these two compounds were nearly identical (Fig. S11†).
 |
| | Fig. 1 Fluorescence spectra of 10 μM Pi-A (A) or Pi-E (B) in the absence and presence of 10 μM Cu2+. Buffer: Tris-HCl (10 mM, pH 7.4), 2% (v/v) DMSO/water. λex = 296 nm. | |
The different fluorescence responses of Pi-A and Pi-E toward Cu2+ were possibly due to the difference in linker which played an indispensable role in Cu2+ sensing. The plausible mechanism for the fluorescent changes of probes and the interaction of probes with Cu2+ were shown in Scheme 2. The excited state intramolecular proton transfer (ESIPT) process occurred in Pi-A molecule.42–46 The H atom of the amide was transferred to the N atom of the phenanthroimidazole group, which gave a strong fluorescence. Upon addition of Cu2+, the deprotonation took place in the amide group, so the ESIPT process was inhibited which led to a fluorescence quenching of Pi-A. On the contrary, the ESIPT process was blocked in Pi-E molecule due to protection of the hydroxyl group by a 2-pyridinecarboxylate group, thus the free Pi-E showed relatively weak fluorescence. However, a significant fluorescence enhancement of Pi-E could be shown after addition of Cu2+. The fluorescence enhancement should be ascribed to the cleavage of ester bond mediated by Cu2+, which restored the ESIPT process and recovered the tautomer emission.
The sensing mechanism of Pi-A toward Cu2+ was investigated by 1H NMR titration experiments at room temperature. As shown in Fig. 2, the amide NH signal appeared at 13.5 ppm in free Pi-A, which disappeared gradually upon the addition of Cu2+. Meanwhile, the proton signals in the pyridine ring displayed a slight downfield shift, and the peaks broaden relatively because of the turbidity of the solution.47 The NMR studies suggested that the Cu2+ chelates with N atoms of the amide and pyridine moiety, and forms a copper complex. Furthermore, the 2
:
1 stoichiometry of the complexation was confirmed by the Job's plot (Fig. S8†). The interaction mechanism of Pi-E with Cu2+ was confirmed by ESI-mass in which a peak (m/z 400.50) corresponding to the authentic compound 2 was obtained (Fig. S9 and S10†). According to Job's plot (Fig. S8†), the stoichiometry in the reaction of Pi-E with Cu2+ was 1
:
1. Thus, all these results confirmed the correct of the submitted mechanism.
 |
| | Fig. 2 Partial 1H NMR spectra of Pi-A (10 mM) upon titration with various equivalents of Cu2+. | |
Effects of solvents on emission performance
It is well known that the ESIPT process is affected by external parameters (e.g. solvent). Therefore, the emission spectra of the proposed ESIPT dyes (probe Pi-A and compound 2) in different solvents were investigated. As shown in Fig. S12A,† Pi-A exhibited an enol emission with small Stokes shift (about 78 nm) in dimethyl sulfoxide (DMSO). In dichloromethane (DCM), two emission peaks appeared at 352 nm and 416 nm, which were assigned to the enol and keto form emission. However, in methanol no obvious emission was found. In case of compound 2, enol emission prevailed in DMSO and only keto emission appeared in DCM, whereas, dual emissions from the enol and keto forms are observed in protic methanol (Fig. S12B†), which were consistent with results reported in the literature.40 Interestingly, the emission spectra of both Pi-A and compound 2 in DMSO solution showed a large bathochromic shift and enol emission disappearance with increasing water proportions (Fig. S12C and S12D†). This may be due to the aggregation of Pi-A and compound 2.37 Based on the above observations, a DMSO/Tris-HCl (v/v = 1
:
49) solution was selected as the working buffer in the following experiments.
Effects of pH and time
In order to achieve high sensitivity of probes for the detection of Cu2+, the optimization of pH and reaction time is essential. At first, the effect of pH on fluorescence properties of two probes and their response to Cu2+ were investigated. As shown in Fig. S13,† the pH value had no obvious effect on the fluorescence intensity of Pi-A between pH 4.0 and 10.0 both in the absence and presence of Cu2+, suggesting that the fluorescence response of Pi-A toward Cu2+ was actually pH-independent. On the other hand, Pi-E itself showed very weak emission intensity in the pH range of 4.0 to 8.0. When pH > 8.0, the emission intensity of Pi-E was gradually increased, which might be attribute to the partial hydrolysis of the carboxylic ester. Similar to Pi-A, Pi-E showed a good response to Cu2+ in the pH range from 6.0 to 9.0. These suggest that both probes are able to work effectively at the range of physiological pH to more alkaline condition (6.0–9.0). Time-dependent variations in the fluorescence spectra of Pi-A and Pi-E were monitored in the presence of 1 equiv. of Cu2+. It was found that the interaction of these probes with Cu2+ was completed in less than 30 min (Fig. S14†). On the basis of those observations, a physiological pH (pH 7.4) and an assay time of 30 min were selected for the following experiments.
Performance of Cu2+ assays
Under the optimal conditions, the fluorescence responses of Pi-A and Pi-E to various concentrations of Cu2+ were researched. As shown in Fig. 3A, Pi-A itself showed a very strong emission. However, the fluorescence of Pi-A (10 μM) was dramatically decreased upon the addition of Cu2+ and finally sustained to a stable value with the molar ration of Cu2+/Pi-A up to 1
:
2. A good linear relationship between the fluorescence intensity and the Cu2+ concentration ranging from 0 to 3.5 μM was obtained (Fig. 3B). In addition, the limit of detection (LOD) of Cu2+ was calculated to be 1.6 × 10−9 M, indicating that Pi-A is highly sensitive to low concentration of Cu2+.
 |
| | Fig. 3 Fluorescence spectra of 10 μM Pi-A (A) or Pi-E (C) upon addition of varied concentrations of Cu2+. A plot of fluorescence intensity changes of 10 μM Pi-A (B) or Pi-E (D) vs. Cu2+ concentration. Conditions: for Pi-A, λex/λem = 296/455 nm; for Pi-E, λex/λem = 296/481 nm. Buffer: Tris-HCl (10 mM, pH 7.4), 2% (v/v) DMSO/water. | |
Compared to Pi-A, Pi-E showed obvious fluorescence increasement along with the titration of Cu2+, and a maximal fluorescence enhancement was obtained when the concentration of Cu2+ reached 1.0 equiv. (Fig. 3C). The plot of the emission intensity as a function of the Cu2+ concentration shows a good linearity within the concentration range of 0–10.0 μM (Fig. 3D), and the LOD of Pi-E toward Cu2+ was estimated to be 1.8 × 10−8 M. Above results demonstrated that both probes are able to detect Cu2+ quantitatively by the fluorescence method.
The selectivity is another crucial parameter to assess the performance of a new fluorescent probe. Therefore, the selectivity experiments of Pi-A and Pi-E were extended to a variety of environmentally and physiologically active metal ions (Cu2+, Pb2+, Na+, Ca2+, Mg2+, Fe2+, Mn2+, Ag+, Cu+, Cd2+, Zn2+, Ni2+, Fe3+, Co2+, Ba2+ and Hg2+). As illustrated in Fig. 4, the addition of Cu2+ to the solution of Pi-A led to an almost complete fluorescence quenching. In contrast, the addition of Cu2+ produced a significant increase in the fluorescence intensity of Pi-E. However, the addition of the other metal ions did not cause any apparent variations in the fluorescence spectra of both probes. All these results indicated that Pi-A and Pi-E possess high selectivity toward Cu2+ and could meet the selective requirements for practical application.
 |
| | Fig. 4 Fluorescence spectra of 10 μM Pi-A (A) or Pi-E (B) upon addition of various metal ions. Cu2+ was added at a concentration of 10 μM, and other cations (Pb2+, Na+, Ca2+, Mg2+, Fe2+, Mn2+, Ag+, Cu+, Cd2+, Zn2+, Ni2+, Fe3+, Co2+, Ba2+ and Hg2+) were added at a concentration of 200 μM. | |
Imaging of intracellular Cu2+
In order to evaluate the ability of the probes for biological applications, and clarify whether it is sensitive enough to for Cu2+ detecting in living cells, we performed an assay to detect Cu2+ in living cells using Pi-A and Pi-E. HeLa cells were pretreated with 10 μM Pi-A or Pi-E for 30 min, and then incubated with either buffer or buffer containing 10 μM Cu2+ for another 30 min and imaged by inverted fluorescence microscopy. As shown in Fig. 5, after addition of Cu2+ to the cells pretreated with Pi-A, the fluorescence emission from the cells was quenched. But for the cells pretreated with Pi-E, upon adding Cu2+, a remarkable blue emission was observed. The auto-fluorescence from the cells treated with PBS was negligible compared to the blue fluorescence from the cells pretreated with probes (Fig. S15†). These results established that both probes can permeate through cell membranes and sense Cu2+ in the living cells. Due to its off-on response feature, Pi-E is more suitable for bioimaging applications.
 |
| | Fig. 5 Fluorescence microscope images of living HeLa cells. Cells incubated with 10 μM Pi-A (A) or Pi-E (C) for 30 min at 37 °C. HeLa cells pretreated with 10 μM Pi-A (B) or Pi-E (D) for 30 min at 37 °C and then further incubated with 10 μM Cu2+ for another 30 min. Top: Bright field image, Bottom: Fluorescence image. | |
Conclusions
We have synthesized a pair of ESIPT-based fluorescent probes (Pi-A and Pi-E) for in vitro and in vivo detection of Cu2+ by modulating the proton donor in the ESIPT system. Differences in the linker of the probes molecules resulted in completely different sensing behaviour. Pi-A and Pi-E exhibited high selectivity and sensitivity to Cu2+ detection with fluorescence turn-off and turn-on feature under the same conditions, respectively. The experimental results showed that Pi-A and Cu2+ form an 2
:
1 stoichiometric ratio complex, while Pi-E undergo Cu2+-promoted hydrolysis to generate the corresponding product with a stoichiometric ratio of 1
:
1. Both probes have the following attractive properties: convenience in preparation, good water solubility and tolerating a wide pH range. Cell experiments showed that Pi-E is more encouraging for imaging Cu2+ in live cells due to its fluorescence enhancement and good cell-membrane permeability. By utilizing the strategy of the modulation of the proton donor in the ESIPT system, more ESIPT-based probes for other analytes might be developed with similar structure but different performance.
Acknowledgements
This work was supported by the National Natural Science Foundation of China (21375037 and 21405043), Scientific Research Fund of Hunan Provincial Science and Technology Department and Education Department (13JJ2020, 12A084), Scientific Research Fund of Hunan Provincial Education Department (CX2015B166), Hunan Provincial Innovation Foundation for Postgraduate and Doctoral Fund of Ministry of Education of China (no.: 20134306110006).
Notes and references
- D. Maiti, H. R. Lucas, A. A. N. Sarjeant and K. D. Karlin, J. Am. Chem. Soc., 2007, 129, 6998 CrossRef CAS PubMed.
- I. A. Koval, P. Gamez, C. Belle, K. Selmeczi and J. Reedijk, Chem. Soc. Rev., 2006, 35, 814 RSC.
- P. Verwilst, K. Sunwoo and J. S. Kim, Chem. Commun., 2015, 51, 5556 RSC.
- M. W. Bourassa and L. M. Miller, Metallomics, 2012, 4, 721 RSC.
- Y. P. de Peña, W. López, J. L. Burguera, M. Burguera, M. Gallignani, R. Brunetto, P. Carrero, C. Rondon and F. Imbert, Anal. Chim. Acta, 2000, 403, 249 CrossRef.
- J. S. Becker, A. Matusch, C. Depboylu, J. Dobrowolska and M. Zoriy, Anal. Chem., 2007, 79, 6074 CrossRef CAS PubMed.
- Y. Liu, P. Liang and L. Guo, Talanta, 2005, 68, 25 CrossRef CAS PubMed.
- S. Pal, N. Chatterjee and P. K. Bharadwaj, RSC Adv., 2014, 4, 26585 RSC.
- Y. Yang, Q. Zhao, W. Feng and F. Li, Chem. Rev., 2012, 113, 192 CrossRef PubMed.
- J. Huang, M. Liu, X. Ma, Q. Dong, B. Ye, W. Wang and W. Zeng, RSC Adv., 2014, 4, 22964 RSC.
- J. Huang, M. Tang, M. Liu, M. Zhou, Z. Liu, Y. Cao, M. Zhu, S. Liu and W. Zeng, Dyes Pigm., 2014, 107, 1 CrossRef CAS PubMed.
- Y. Yang, F. Huo, C. Yin, Y. Chu, J. Chao, Y. Zhang, J. Zhang, S. Li, H. Lv and A. Zheng, Sens. Actuators, B, 2013, 177, 1189 CrossRef CAS PubMed.
- H.-T. Feng, S. Song, Y.-C. Chen, C.-H. Shen and Y.-S. Zheng, J. Mater. Chem. C, 2014, 2, 2353 RSC.
- L. Feng, H. Li, Y. Lv and Y. Guan, Analyst, 2012, 137, 5829 RSC.
- J. Kovács and A. Mokhir, Inorg. Chem., 2008, 47, 1880 CrossRef PubMed.
- M. H. Kim, H. H. Jang, S. Yi, S.-K. Chang and M. S. Han, Chem. Commun., 2009, 4838 RSC.
- N. Li, Y. Xiang and A. Tong, Chem. Commun., 2010, 46, 3363 RSC.
- W. Lin, L. Long, B. Chen, W. Tan and W. Gao, Chem. Commun., 2010, 46, 1311 RSC.
- V. Dujols, F. Ford and A. W. Czarnik, J. Am. Chem. Soc., 1997, 119, 7386 CrossRef CAS.
- M.-M. Yu, Z.-X. Li, L.-H. Wei, D.-H. Wei and M.-S. Tang, Org. Lett., 2008, 10, 5115 CrossRef CAS PubMed.
- W. Lin, L. Yuan, W. Tan, J. Feng and L. Long, Chem.–Eur. J., 2009, 15, 1030 CrossRef CAS PubMed.
- E. Sanna, L. Martínez, C. Rotger, S. Blasco, J. González, E. García-España and A. Costa, Org. Lett., 2010, 12, 3840 CrossRef CAS PubMed.
- K. L. Ciesienski, L. M. Hyman, S. Derisavifard and K. J. Franz, Inorg. Chem., 2010, 49, 6808 CrossRef CAS PubMed.
- U. N. Yadav, P. Pant, S. K. Sahoo and G. S. Shankarling, RSC Adv., 2014, 4, 42647 RSC.
- D. P. Kennedy, C. M. Kormos and S. C. Burdette, J. Am. Chem. Soc., 2009, 131, 8578 CrossRef CAS PubMed.
- F. Chen, G. Liu, Y. Shi, P. Xi, J. Cheng, J. Hong, R. Shen, X. Yao, D. Bai and Z. Zeng, Talanta, 2014, 124, 139 CrossRef CAS PubMed.
- N. R. Chereddy, S. Janakipriya, P. S. Korrapati, S. Thennarasu and A. B. Mandal, Analyst, 2013, 138, 1130 RSC.
- B. Fang, Y. Liang and F. Chen, Talanta, 2014, 119, 601 CrossRef CAS PubMed.
- A. Mokhir and R. Krämer, Chem. Commun., 2005, 2244 RSC.
- K. Benelhadj, W. Muzuzu, J. Massue, P. Retailleau, A. Charaf-Eddin, A. D. Laurent, D. Jacquemin, G. Ulrich and R. Ziessel, Chem.–Eur. J., 2014, 20, 12843 CrossRef CAS PubMed.
- T. Mutai, H. Tomoda, T. Ohkawa, Y. Yabe and K. Araki, Angew. Chem., Int. Ed., 2008, 47, 9522 CrossRef CAS PubMed.
- A. I. Ciuciu, K. Skonieczny, D. Koszelewski, D. T. Gryko and L. Flamigni, J. Phys. Chem. C, 2013, 117, 791 CAS.
- A. I. Ciuciu, L. Flamigni, K. Skonieczny and D. T. Gryko, Phys. Chem. Chem. Phys., 2013, 15, 16907 RSC.
- J. E. Kwon, S. Park and S. Y. Park, J. Am. Chem. Soc., 2013, 135, 11239 CrossRef CAS PubMed.
- S. Park, J. E. Kwon, S. H. Kim, J. Seo, K. Chung, S.-Y. Park, D.-J. Jang, B. A. M. N. Medina, J. Gierschner and S. Y. Park, J. Am. Chem. Soc., 2009, 131, 14043 CrossRef CAS PubMed.
- B. Gu, L. Huang, N. Mi, P. Yin, Y. Zhang, X. Tu, X. Luo, S. Luo and S. Yao, Analyst, 2015, 140, 2778 RSC.
- Y. Zhang, J.-H. Wang, W. Zheng, T. Chen, Q.-X. Tong and D. Li, J. Mater. Chem. B, 2014, 2, 4159 RSC.
- H.-W. Tseng, J.-Q. Liu, Y.-A. Chen, C.-M. Chao, K.-M. Liu, C.-L. Chen, T.-C. Lin, C.-H. Hung, Y.-L. Chou and T.-C. Lin, J. Phys. Chem. Lett., 2015, 6, 1477 CrossRef CAS PubMed.
- L. Tang, M. Cai, P. Zhou, J. Zhao, K. Zhong, S. Hou and Y. Bian, RSC Adv., 2013, 3, 16802 RSC.
- K. Skonieczny, A. I. Ciuciu, E. M. Nichols, V. Hugues, M. Blanchard-Desce, L. Flamigni and D. T. Gryko, J. Mater. Chem., 2012, 22, 20649 RSC.
- K. Zheng, W. Lin and L. Tan, Org. Biomol. Chem., 2012, 10, 9683 CAS.
- C.-B. Huang, H.-R. Li, Y. Luo and L. Xu, Dalton Trans., 2014, 43, 8102 RSC.
- L. Tang, Z. Zheng, Z. Huang, K. Zhong, Y. Bian and R. Nandhakumar, RSC Adv., 2015, 5, 10505 RSC.
- W.-H. Chen, Y. Xing and Y. Pang, Org. Lett., 2011, 13, 1362 CrossRef CAS PubMed.
- Z. Zhou, N. Li and A. Tong, Anal. Chim. Acta, 2011, 702, 81 CrossRef CAS PubMed.
- C. Zhao, P. Feng, J. Cao, X. Wang, Y. Yang, Y. Zhang, J. Zhang and Y. Zhang, Org. Biomol. Chem., 2012, 10, 3104 CAS.
- S. Lee, B. A. Rao and Y.-A. Son, Sens. Actuators, B, 2014, 196, 388 CrossRef CAS PubMed.
Footnote |
| † Electronic supplementary information (ESI) available. See DOI: 10.1039/c5ra14443d |
|
| This journal is © The Royal Society of Chemistry 2015 |
Click here to see how this site uses Cookies. View our privacy policy here.