Manish Varyani,
Indrajit K. Ghosh and
Suman L. Jain*
Chemical Sciences Division, CSIR-Indian Institute of Petroleum, Dehradun-248005, India. E-mail: suman@iip.res.in; Fax: +91-135-2660202; Tel: +91-135-2525788
First published on 7th September 2015
Liquid range polyethylene glycols containing copper ions have been used as recyclable extractive media for the selective separation of 1-decene from a mixture of 1-decene and n-decane. The copper(II) ions in PEG were readily converted into copper(I) and then selectively coordinated with 1-decene molecules through π-complexation. The resulting polyethylene glycol phase containing copper–olefin complex was treated with n-heptane at 70–80 °C to obtain pure 1-decene and the recovered poly(ethylene)glycol containing copper ions was successfully reused for several runs.
The separation of unsaturated hydrocarbons (olefins) from saturated hydrocarbons (paraffins) is an industrially important task. In general olefins are mainly produced by thermal and catalytic cracking of hydrocarbon streams. Since the product streams from these cracking processes contain alkanes and alkenes with the same carbon numbers which are of narrow boiling point differences, therefore, their separation is quite difficult and expensive by so called conventional cryogenic distillation.12,13 Also, comparatively less costly extractive distillation will not significantly improve this separation, because all isomers respond in a similar way to the solvent, leaving the relative volatility almost unchanged. Consequently, alternative strategies to separate olefin/paraffin mixtures that would result in cost and energy savings are of great interest. The specific and reversible interaction of metal ions particularly silver and copper with olefin molecules leads to selective recovery of the olefins from paraffins.14,15 In this regard, a very few reports for the separation of olefins via reversible π-complexation using copper ions in aqueous16 and non-aqueous17 media are known; however separation of olefins using silver ions has been widely studied.18,19 Recently, silver functionalized ionic liquids owing to their negligible vapour pressure, recycling ability and non-toxic nature have been emerged to be greener and potential solvents for the separation of liquid range of olefins via extraction. However, expensive nature of silver salts/complexes and tedious preparation of ionic liquids make their utility limited.20 Furthermore, some of the “green” aspects related to the toxicity and biodegradability of ionic liquids are still under discussion, and achieving good purity of extract remains a challenging task.
Herein we report for the first time the use of liquid range polyethylene glycols mixed with copper(II) salt for the selective separation of 1-decene from the mixture of 1-decene and n-decane. The coordination of copper(II) ions with polyethylene glycol resulted in the reduction of Cu2+ to Cu1+ ions, which leads to a favorable selectivity of extraction for 1-decene via π-complexation from a mixture of 1-decene/n-decane.
For the present study, we have chosen a hydrocarbon phase containing n-decane and 1-decene as a representative example and PEG200 and PEG400 as extractive medium. We have used n-decane and polyethylene glycol in 1
:
1 ratio (by volume). The schematic presentation of the separation of 1-decene/n-decane by reversible π-complexation with copper ions in poly(ethylene)glycol extractive medium is shown in Scheme 1. The whole process for the selective separation of 1-decene comprises of three steps: firstly, transfer of 1-decene from hydrocarbon phase to PEG phase through the formation of Cu–olefin complex at room temperature; secondly, separation of the PEG phase containing Cu–olefin complex from hydrocarbon phase by physical method; thirdly, reversing the complex to recover the olefin by treating the PEG phase with n-heptane at higher temperature.
At first, the separation of 1-decene from n-decane using PEG solution containing copper ions (0.02 mol L−1) have been studied. For each experiment, 5 ml of PEG containing copper ion (0.02 mol L−1) as a extractive phase and 5 ml of n-decane containing 0.02 mol L−1 1-decene as hydrocarbon phase were used. Copper(II) ions in the extractive medium in the presence of PEG readily reduced to copper(I) ions. These copper(I) ions were selectively coordinated to 1-decene molecules through π-complexation to form 1
:
1 copper–olefin complex species. The in situ reduction of copper(II) ions in PEG to copper(I) ions was confirmed by cyclic voltametric studies as shown in Fig. 1. The cyclic voltammogram for copper(II) tetrafloroborate in PEG200 was found to be in good agreement with the existing literature report.21 As suggested in the literature PEG not only reduces the copper(II) ions to copper(I) ions but also provide the stability to these ions through complexation.21
To see the effect of various copper precursors, copper(II)chloride and copper(II)tetrafluoroborate were used as the source of copper ions for the selective separation of olefins. Liquid poly(ethylene)glycols e.g. PEG200 and PEG400 were used to dissolve the copper salts for the concentration of copper ions 0.04 mol L−1. Among the various extractants studied, copper(II)tetrafluoroborate dissolved in PEG200 was found to be optimum for the maximum separation of 1-decene from the mixture of n-decane and 1-decene (Table 1, entry 5). To determine the effect of copper ions on the selectivity of the paraffin/olefin separation process, pure PEG solvents without copper were also studied. The pure poly(ethylene)glycols did not show any selectivity for the separation of 1-decene, confirming that the copper ions are essentially required for the separation of olefins from a mixture containing paraffin/olefin (Table 1, entry 1 and 2). Similarly the use of other solvents such as methanol, acetonitrile and water gave a very poor separation of 1-decene (Table 1, entry 7–9), which is most likely due to the inability of these solvents to reduce copper(II) ions to copper(I) ions.
| Entry | Extractant | Conc. of Cu ion (mol L−1) | 1-Decene extraction (%) | Std. deviation |
|---|---|---|---|---|
a Condition: PEG : n-decane (1 : 1; by volume), hydrocarbon phase (n-decane) consisting of 1-decene (0.02 mol L−1) at 293 K, time 4 h. |
||||
| 1 | PEG200 | — | — | — |
| 2 | PEG400 | — | — | — |
| 3 | CuCl2 in PEG200 | 0.04 | 90.9–92.0 | 0.778 |
| 4 | CuCl2 in PEG400 | 0.04 | 88.7–90.0 | 0.919 |
| 5 | Cu(BF4)2 in PEG200 | 0.04 | 98.3–99.2 | 0.636 |
| 6 | Cu(BF4)2 in PEG400 | 0.04 | 96.7–98.1 | 0.990 |
| 7 | Cu(BF4)2 in ethanol | 0.04 | 71.6–72.4 | 0.566 |
| 8 | Cu(BF4)2 in acetonitrile | 0.04 | 68.9–70.2 | 0.919 |
| 9 | Cu(BF4)2 in water | 0.04 | 74.7–76.2 | 1.061 |
The selectivity for the separation of 1-decene from n-decane were also studied under varying concentration of copper ions in PEG200 from 0.01 to 0.06 mol L−1 (Fig. 2). It was found that with the increase in copper ion concentration in PEG, transfer of 1-decene from hydrocarbon phase gradually increased till olefin to Cu ratio 1
:
2. Thus the optimum concentration of copper ions for 0.02 mol L−1 1-decene was found to be 0.04 mol L−1 as shown in Fig. 2. Further increase in concentration of copper ions affected the extraction of olefin adversely, which is probably due to the hindrance caused by excess metal ions.
![]() | ||
Fig. 2 Effect of copper ion concentration in PEG on extraction of 1-decene (n-decane : PEG200 = 1 : 1 by volume (5 ml each); [Cu2+] = 0.01–0.06 mol L−1; time 4 h). | ||
It is well documented in the literature that copper(I) ions readily coordinate with olefins to give reversible π-complexes at lower temperatures.22–25 To evaluate the effect of temperature on the extraction of olefin, experiments were conducted at varying range of temperature 283 K to 323 K (Fig. 3). It was observed that the separation of 1-decene by Cu–PEG solution was increased with decrease in temperature which is quite relevant with the exothermic nature of the formation of π-complexes.
It was also found that with increase in the initial concentration of olefin (0.01–0.04 mol L−1) in hydrocarbon/organic phase, the percentage of extraction decreased. The results shown in Fig. 4 indicated that increasing the initial concentration of 1-decene from 0.01 to 0.02 mol L−1 in feed, the percentage of extraction increased at all three temperatures, whereas further increase from 0.02 to 0.04 mol L−1 resulted to the significant decrease in extraction of 1-decene. This is most likely due to the limited availability of the copper ions for the complexation with the excess olefin molecules.
Furthermore, in the present study we developed a simple and efficient approach for the recovery of the pure olefin from the PEG phase containing copper–olefin complex. Few of the literature reports suggested the use of polar solvents for the recovery of olefins from metal–olefin complex via extractive distillation approach.26,27 However, this process associated with the drawbacks of poor recovery of the olefin. To overcome such limitations, we have chosen n-heptane, which is completely miscible with olefin but remains insoluble in PEG, for the recovery of pure 1-decene from the PEG–copper phase. PEG phase containing Cu–olefin complex was separated from the hydrocarbon phase simply by gravity settling and then treated with n-heptane at 80 °C. Removal of the solvent under reduced pressure yielded pure 1-decene. The olefin sample was further analyzed by ICP-AES and results indicated that there was no metal obtained during the recovery process. These studies suggested that copper ions remained in PEG phase, whereas olefin was selectively recovered in n-heptane solvent.
Last but not least, we checked the recyclability of recovered copper containing PEG200 for six runs under the described conditions. The results of these experiments are summarized in Fig. 5. As shown, the recovered PEG–copper phase showed almost similar efficiency for the separation of 1-decene from the mixture of n-decane/1-decene.
GC Model: VARIAN CP-3800; Column: CP-Sil 24 CB-MS-CP5817;
Dimension: 30 m × 0.25 mm × 0.25 μm; injector temperature: 270 °C.
Injector type: Programmed Temperature Vaporizing injector (PTV) FID detector temperature: 300 °C.
Column oven temperature programme:
| Rate (°C min−1) | Temperature (°C) | Hold time (min) | Total time (min) |
|---|---|---|---|
| Initial | 40 | 2.0 | 2.0 |
| 5.0 | 120 | 2.0 | 20 |
| 5.0 | 250 | 10 | 56 |
| Total time | 56.00 | ||
The RT of components in GC:
| Component | RT |
|---|---|
| n-Decane | 13.61–13.72 |
| 1-Decene | 13.85–13.88 |
The percentage of component extracted or separated is calculated by:
The concentration of hydrocarbon components from GC was calculated by taking the area percentage directly from the chromatogram at the respective RT of components. The response factor of FID was found to be almost closer to 1.00, which was calculated by comparing the % area from chromatogram at all the RTs with the percentage composition of the respective components in the standard mixture of hydrocarbons (C8–C10).
| This journal is © The Royal Society of Chemistry 2015 |