Martin
Grützke
,
Xaver
Mönnighoff
,
Fabian
Horsthemke
,
Vadim
Kraft
,
Martin
Winter
and
Sascha
Nowak
*
University of Münster, MEET Battery Research Center, Institute of Physical Chemistry, Corrensstraße 46, 48149 Münster, Germany. E-mail: sascha.nowak@uni-muenster.de; Fax: +49-251-83 36032
First published on 8th May 2015
A flow-through method for the extraction of lithium-ion battery electrolytes with supercritical and liquid carbon dioxide (sc and liq CO2) under the addition of different solvents has been developed and optimized to achieve quantitative extraction of the electrolyte from commercial LiNi1/3Co1/3Mn1/3O2 (NMC)/graphite 18650 cells. Furthermore, the time-dependence of the extraction procedure was investigated and demonstrated. The extracts were analyzed with gas and ion chromatography. Linear carbonates like dimethyl carbonate (DMC) and ethyl methyl carbonate (EMC), respectively, were better extracted with liq CO2, whereas the cyclic carbonate ethylene carbonate (EC) was recovered in higher amounts with sc CO2. The addition of solvents to the CO2 resulted in improved recovery for all the ingredients but most effectively for LiPF6, which could not be obtained by extraction with CO2 only. The best results were achieved by extracting for 30 minutes with liq CO2 (25 °C, 60 bar) and 0.5 mL min−1 acetonitrile (ACN)/propylene carbonate (PC) in a mixture of three to one and an additional 20 minutes with liq CO2 only, to yield (89.1 ± 3.4) wt% electrolyte in almost its original composition of DMC, EMC, EC (1:1:1) with 1.1 mol L−1 LiPF6. Therefore, the presented method can be relevant for the recycling of lithium ion battery electrolytes but has to be validated for up-scaled processes. Furthermore, the suitability of CO2 extraction as a tool for post-mortem or aging investigations of LIB electrolytes could once more successfully be demonstrated due to the extraction of aging products like diethyl-2,5-dioxahexane dicarboxylate (DEDOHC) from a pouch cell, which was electrochemically aged for 1000 cycles at 1 C. In this context, extraction times and recovery rates were drastically improved compared to our previously reported static extraction experiments.
In addition to its gaseous, liquid and solid phase, carbon dioxide shows a relatively easy available supercritical phase after adjusting temperature and pressure above the critical point which is at 31 °C and 74 bar.23 The dissolving properties of sc CO2 are comparably high for many organic substances, especially in combination with additional solvents. Thus, CO2 is the most applied extraction medium in supercritical fluid extraction (SFE).24 The most prominent example for the application of sc CO2 extraction might be the decaffeination process of coffee.25,26 Likewise, sc CO2 is generally used a lot as extraction medium in food chemistry.27–29 Furthermore, its usage as eluent is also important in supercritical fluid chromatography (SFC),24 as drying agent in crack free silica aerogel production30,31 and as reaction medium in olefin polymerization reactions32 or metal nanoparticle synthesis.33
Sloop et al. described the extraction of electrolytes from energy storage devices with supercritical fluids.34 LIBs were mentioned in this patent but detailed information about the extraction behavior were rare. LIBs are the most applied energy storage systems for modern consumer and portable electronics like smartphones and cameras, and the most promising battery technology for electric or hybrid electric vehicles.35,36 LIBs usually consist of a graphitic anode and a transition metal oxide77 or phosphate cathode78 with a polymeric or ceramic separator in between. A non-aqueous aprotic electrolyte serves for charge transfer in form of lithium-ions. Electrolytes for LIBs are made of different linear carbonates (e.g. dimethyl carbonate (DMC) and ethyl methyl carbonate (EMC)) in a mixture with ethylene carbonate (EC).11,12,37 LiPF6 is generally used as conducting salt and dissolved in this solution in concentrations of about 1 mol L−1. Moreover, additives for various electrolyte properties can be present.38,39 Dimethyl methylphosphonate can be applied as flame retardant,40 cyclohexylbenzene for overcharge protection11 and vinylene carbonate as film forming additive for controlled formation of the SEI.11,12,41–46
Different aging processes occur in LIBs which lead to a creeping loss of capacity and a limited cell lifetime.47 One of these aging effects is the decomposition of the electrolyte during cycling which is furthermore influenced by the temperature and the quality of each and every compound in the cell, especially with regards to protic impurities. Research on electrolyte decomposition as well as the development of new and specific analytical methods has been done in recent years,38,48–67 but there is still a far way to go until the complete picture of electrolyte aging in LIBs is fully understood. Furthermore, the quantitatively extraction from the LIBs is of interest for recycling processes. Since 50 wt% of a cell has to be recovered, the electrolyte represents a target component for the recycling of LIBs. Additionally, fluoride or fluorinated compounds can hamper or damaged industrial scaled recycling processes and have to be removed as well.
We recently reported the extraction of LIB electrolytes with supercritical helium head pressure carbon dioxide (sc HHPCO2) in a simple autoclave setup.63 A successful proof of principle experiment was demonstrated. Furthermore, the sc HHPCO2 extraction could be presented as sample preparation tool for LIB post-mortem aging investigations. HHPCO2 was used in these experiments to keep the experimental equipment as easy as possible. Sc CO2 conditions can be achieved without a compressor already from the bottle. Nevertheless, HHPCO2 is more expensive than conventional liq CO2 with the same purity. Furthermore, the recovery rate for the electrolyte from the investigated 18650 cells was relatively low (<10 wt%). Moreover, it was not possible to obtain the conducting salt but only the organic carbonates. To overcome these drawbacks and to further investigate the extraction of LIB electrolytes with CO2 we installed a conventional flow-through SFE extraction unit. Herein, we report the results for the extraction of commercial 18650 cells (2.2 Ah) as well as in-house-made pouch cells (4.8 Ah), both based on LiNi1/3Co1/3Mn1/3O2 (NMC)/graphite electrode chemistry, with liquid and supercritical carbon dioxide regarding the recovery rate of the particular electrolyte components, additional solvents in the CO2-stream and the time dependency of the extraction procedure. Since, one investigation was the recycling and aging of LIBs, we decided to use electrolytes which are state-of-the-art in commercial applied LIBs. Nevertheless, it is still possible to investigate alternative systems.
Fig. 2 Compositions of the recovered electrolyte from commercial 18650 cells after formation extracted with supercritical (A) and liquid (B) CO2 for the first three data points of Fig. 1 determined with GC-MS. Blue, top: EC; yellow, middle: EMC; magenta, bottom: DMC. |
For the results in Fig. 3–6, additional solvent (ACN, DEC, PC) with a flow of 0.5 mL min−1 was added to the CO2-stream. After an equilibration step of 30 min at the beginning with CO2, but without solvent, it was extracted in flow-through for two minutes with subsequent 5 min of static equilibration time. The (2 + 5) min step was repeated 15 times, followed by 20 min flow-through extraction without solvent (only CO2).
Samples were diluted 1:10 to 1:50 with water for anion analysis and 20 μL were injected. An aqueous eluent with 1.8 mmol L−1 Na2CO3 and 1.7 mmol L−1 NaHCO3 was used with a flow of 1 mL min−1 on a Metrosep A Supp 4-250/4.0 + Metrosep A Supp 4/5 Guard/4.0 column at a temperature of 40 °C. After 10 min, a gradient step was applied and over 3 min, ACN was added up to a concentration of 50 vol%. F− could be confirmed via the retention time of a standard solution. PO2F2−, PF6− and alkyl fluoro phosphates were identified with IC hyphenated to electrospray ionization-mass spectrometry (ESI-MS). Equipment, procedure and conditions were recently published and applied.60,64,65
Quantitative results were obtained with appropriate dilution of the samples to be within the external five-point calibration (R2 > 0.999) in a range of 10 mg kg−1 to 1500 mg kg−1 (10 mg kg−1 to 100 mg kg−1 for DEDOHC) under the same GC-MS conditions as just described but with single ion monitoring (SIM) via the following ions: DMC (59 m/z), EMC (77 m/z), DEC (91 m/z), PC (102 m/z), EC (88 m/z) and DEDOHC (89 m/z). Each sample and concentration was measured two times. Limits of detection (LOD) and limits of quantification (LOQ) were determined according to DIN 32645: DMC (31.7 mg L−1, 121.0 mg kg−1), EMC (14.9 mg kg−1, 56.9 mg kg−1), DEC (12.0 mg kg−1, 46.3 mg kg−1), PC (11.7 mg kg−1, 49.4 mg kg−1), EC (13.3 mg kg−1, 51.1 mg kg−1) and DEDOHC (3.6 mg kg−1, 14.0 mg kg−1).
After adjusting these first parameters, further method development was done with 2.2 Ah, NMC/graphite commercial 18650 cells (Panasonic CGR18650CH Li-ion MH12210). The uncoiled jelly roll was densely packed into the extraction chamber. Variation of the pressure at supercritical extraction conditions (40 °C, 80 bar vs. 300 bar) resulted only in slightly different recovery rates at the same CO2 flow, whereas variation of the flow at the same pressure gave much higher recovery rates (by weight) in the same time. Unfortunately this parameter was limited due to the mentioned Joule–Thomson-Effect because CO2 simply freezes out in the cryogenic trap when the flow is too high. Thus, the flow was adjusted to 15 L min−1 at the outlet valve for all further experiments as good compromise between high flow rate (which means short extraction times) and resublimating CO2. The CO2 flow control of the outlet valve over time showed, that the used extraction equipment could not better be adjusted than within 20% relative standard deviation which means a CO2 flow of (15 ± 3) L min−1.
Two different CO2 conditions were compared. While extracting with liq CO2 (25 °C, 60 bar), we reproducibly achieved a higher amount of extracted electrolyte at the same extraction time and volumetric flow as with sc CO2 (40 °C, 300 bar). This may be explained by differences due to the flow behavior of liquid CO2 compared to sc CO2 (laminar vs. non-laminar). We further investigated this behavior in a time-resolved experiment (Fig. 1), which confirmed our results. Most of the extracted amount is obtained in the first minutes. Also the better recovery with liq CO2 already happens at the beginning of the extraction. The demonstrated data show exponential behavior over time. and therefore the deviation during. Analyses of the extracts of the first minutes with GC-MS reveal that the linear carbonates, DMC and EMC, are extracted with higher efficiency than EC (Fig. 2). Interestingly, the higher amount which is achieved with liq CO2 is only linear carbonates. Compared to liq CO2, extraction with sc CO2 is better suited for EC. CO2 is a relatively nonpolar extraction medium26 which explains why the more polar EC (dipole moment: 4.61 D) is less well extracted than DMC (0.76 D) and EMC (0.89 D).11 This nonpolarity is also the reason for the poor extraction of the conducting salt which could only be gained in trace amounts (as confirmed by IC), which was also observed for the extraction of the same 18650 cells with sc HHPCO2 with a different experimental setup.63 The amount of electrolyte in the investigated 18650 cells was determined to 3.76 g by drying an opened cell at 120 °C in vacuum over 10 hours. We concluded that this amount could not be reached under the so far applied extraction conditions. Only the linear carbonates could quantitatively be recovered after a very long extraction time (over 3 h).
To overcome (i) these drawbacks of long extraction times, (ii) the small concentration of EC and (iii) the not extracted conducting salt, extraction experiments with added solvents to the liq CO2 were realized. The time-resolved results for three different additional solvents are summarized in Fig. 3. The exponential behavior ends at 50 min of extraction time at recovery rates which are much higher compared to extraction with sc CO2 or liq CO2 without additional solvents. The experiments with ACN and DEC show a similar trend with high recovery rates in the first minutes compared to the ACN/PC mixture, which leads to an indolent extraction at first, but finishes with the best overall result. An experiment with only PC as added solvent was also carried out but the collected extract was with about 2 g after the applied extraction method of 50 min much less than the three scenarios demonstrated in Fig. 3. Furthermore, a large amount of the PC apparently remained in the solid battery material during this time, which could be confirmed by weight and also by the 'wet' solid battery material after the extraction chamber was opened for cleaning purposes subsequent to the extraction experiment. Thus, it can be concluded that the addition of very polar solvents (dipole moment PC: 4.81 D)11 is only reasonable when additional solvents with medium polarity are present, that act as “moderator” between very polar solvent and the rather unpolar CO2.
Fig. 4 shows the compositions of the extracts over the whole period of extraction with DEC as additional solvent. The trend is identical to the extraction process without additional solvent. The linear carbonates (DMC and EMC) are extracted well in the first minutes, but the absolute amount is almost doubled compared to extraction with CO2 only. Furthermore, also high recoveries of EC and even of the conducting salt LiPF6 could be achieved. Fig. 5 demonstrates the GC-MS measurements corresponding to the compositions of the volatile components in Fig. 4. It can be seen that the linear carbonates are only significantly extracted in the first 20 min, whereas EC is present in the same magnitude till the end of the extraction experiment. Fig. 6 summarizes the amounts of recovered electrolyte and their compositions for the three discussed scenarios (see Fig. 3). Additionally, the composition of a reference electrolyte is shown. The reference data are the result of the quantitative investigation of electrolyte (10 μL) which was collected during cell opening. The resulted weight percentages are normalized to the amount of electrolyte per 18650 cell. In all cases of extraction with liq CO2 and additional solvents, the linear carbonates could be recovered quantitatively within the limits of error; EC and LiPF6 could be retrieved at least qualitatively. The best overall recovery rate was achieved for the added ACN/PC mixture, with (89.1 ± 3.4) wt% and furthermore with the highest concentrations for EC and LiPF6.
Fig. 4 Compositions of the recovered electrolyte from commercial 18650 cells after formation extracted with liquid CO2 and additional DEC in the CO2-stream determined with GC-MS and IC corresponding to Fig. 3. Red, top: LiPF6; blue, below: EC; yellow, middle: EMC; magenta, bottom: DMC. |
Fig. 5 Chromatograms (GC-MS) of the time-resolved electrolyte recovery which was extracted with liquid CO2 and additional DEC, corresponding to Fig. 3 and 4. |
Finally, we also investigated self-made pouch cells (graphite/NMC) after formation and after “electrochemical aging”, which were bigger than the so far used 18650 cells (4.8 Ah vs. 2.2 Ah). The results of the cycling experiment (=electrochemical aging) for 1000 charge/discharge cycles at a rate of 1 C are displayed in Fig. 7. An electrolyte consisting of 1 mol L−1 LiPF6 in a DEC, PC, EC, VC mixture was applied (quantitative composition see Table 1). All components, except VC, could be detected in the extract, which was achieved with liq CO2 and ACN as additional solvent. PC as additional solvent was not applied in this case due to its presence in the cells and therefore possible difficulties in quantification of the extract. VC had presumably been consumed during the formation cycle and thus been involved in the SEI formation.11,55 In addition to the deployed electrolyte components, DEDOHC, which is an electrolyte aging product, whose formation was already intensively discussed in literature,48,51,54–58,63,66 could clearly be identified. This confirms the result of our previous study, that CO2 can be applied as extraction agent for post-mortem or aging investigations. Fig. 8 shows the GC-MS chromatograms corresponding to the aged cell and, consequently, the extract compositions of the collected fractions. The same picture was achieved for the cell after formation. The findings for DEC, EC and PC are in good agreement to the results of the 18650 cells.
Fig. 7 Discharge capacities for an in-house-made 4.8 Ah pouch cell (cycled at room temperature at a rate of 1 C between 3.0 V and 4.2 V). |
DEC | PC | EC | VC | LiPF6 |
---|---|---|---|---|
46.9 ± 2.2 | 4.5 ± 0.1 | 32.4 ± 0.7 | 2.0 ± 0.1 | 11.7 ± 0.3 |
Fig. 8 Chromatograms (GC-MS) of the time-resolved electrolyte recovery from a cycled (=electrochemically aged) pouch cell (Fig. 7) which was extracted with liquid CO2 and additional ACN. The absolute intensity is amplified by one order of magnitude for the last minute of retention time. |
DEDOHC could be extracted from the cells after formation and cycling, in the same amount of (0.4 ± 0.1) wt% within the first four minutes. Therefore, it is concluded, that DEDOHC is only formed during formation. The 18650 cell showed a different aging behavior in this case. The concentrations of DEDOHC and its derivatives were in correlation with an ongoing film growth during cycling.63 The reason for this difference could be the presence or absence, respectively of VC as electrolyte additive for controlled SEI formation.11 On the other hand, the pouch cells showed a state-of-health (SOH) of over 97% after 1000 cycles (Fig. 7), compared to 70% SOH for the 18650 cells, which makes a quantitative comparison of the two cell types difficult.
Moreover, we could detect traces of decomposition products of the conducting salt LiPF6, such as F−, PO2F2− and different fluoro phosphates with IC and IC hyphenated to electrospray ionization mass spectrometry (ESI-MS) in all samples, even for the cells, which were extracted without additional solvents. This confirms once more the suitability of CO2 extraction as sample preparation tool for post-mortem or aging investigations of LIB electrolytes.