Xuting An,
Shujuan Zhuo*,
Ping Zhang and
Changqing Zhu*
Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, 241000, PR China. E-mail: sjzhuo@mail.ahnu.edu.cn; zhucq@mail.ahnu.edu.cn; Fax: +86 553 3869303; Tel: +86 553 3937137
First published on 11th February 2015
In this paper, we have presented a facile, economic and green one-step hydrothermal synthesis route using tannic acid as carbon source to prepare water-soluble fluorescent carbon dots (CDs). The as-prepared CDs contain distinctive catechol groups on their surfaces, which have a special response toward Fe3+ ions. So the fluorescence emission of CDs gradually decreased with increasing Fe3+ ions. Such fluorescence responses can be used for well quantifying Fe3+ ions in the range of 0–5 μM with the detection limit of 24.4 nM. Most importantly, quenched fluorescence of CDs–Fe3+ could be recovered with the addition of oxytetracycline hydrochloride based on a competition mechanism, which provides a turn-on sensing strategy for oxytetracycline hydrochloride assay. The proposed sensing system has been successfully used for the assay of oxytetracycline hydrochloride in milk samples, indicating the practical potential.
Fluorescent technique,14,15 as a powerful tool, is superior due to its nondestructive nature, high sensitivity and wide dynamic ranges. High sensitivity is particularly important, considering the maximum residual value of OTC in drugs and human food is only 0.1 mg L−1 announced by world health organization.16 Furthermore, the design of fluorescent probes for turn-on sensing of analytes is especially significant because it can effectively enhance sensing sensitivity by decreasing the background interference.17
Herein, we propose a novel strategy for carbon dots (CDs) fluorescence off/on modulation and demonstrate the corresponding application for turn-on sensing of OTC. The CDs are fabricated by on-step “synthesis modification integration” using tannic acid as precursor. So, the as-prepared CDs are directly functionalized by catechol groups (one of the most commonly used recognition sites for Fe3+) in the particle synthesis. As a consequence, the added Fe3+ can lead to the assembly of the CDs based on the coordination binding between the Fe3+ and catechol groups on the CDs surface, which cause the almost complete quenching of the fluorescence emission. Interestingly, the fluorescence of the pre-quenched CDs is then gradually recovered in the presence of OTC due to the competition coordination (see Scheme 1). Such fluorescence response can be used for well quantifying OTC in the range of 0.1–2.7 μM with 22.8 nM detection limit, and has been successfully used for the assay of OTC in real milk samples. Due to simplicity and effectivity, it exhibits great promise as a practical platform for OTC sensing.
Raman spectrum is measured to confirm the quality of the as-prepared CDs. The Raman spectrum of the CDs (Fig. S2†) displays two distinct peaks at 1343 and 1580 cm−1, which are attributed to the D-band (sp3) and G-band (sp2), respectively. The D-band is associated with vibrations of carbon atoms with dangling bonds in the termination plane of disordered graphite or glassy carbon. The G-band is associated with the E2g mode of graphite and is related to the vibration of sp2-bonded carbon atoms in a two-dimensional hexagonal lattice.18
The surface structure and composition of the as-prepared CDs were then investigated. The FT-IR spectrum (Fig. S3†) of the CDs exhibits distinct absorption bands at 3300, 1700, 1400 and 1200 cm−1, corresponding to the groups of OH, C=O, COOH and C–OH vibration mode,19,20 respectively, imply the existence of large numbers of residual hydroxyl groups. In addition, the characteristic bands corresponding to the benzene skeleton vibrations can be observed at 1600 and 1450 cm−1,21 and the benzene out-of-plane bending vibrations of C–H centered at 760 and 625 cm−1 are also appeared, indicating that benzene ring is present on the surface of the as-prepared CDs.
For a better insight, XPS measurements were performed. As shown in Fig. 2a, no peaks of other elements except C (282.2 eV) and O (533.9 eV) are observed. XPS analysis of the C1s spectrum (Fig. 2b) shows three peaks at 284.4, 285.9 and 288.5 eV, corresponding to C=C (45.55%), C–O (38.89%) and C=O (15.55%), respectively.22 The O1s spectrum (Fig. 2c) consists of two peaks at 531.3 and 532.7 eV, which are ascribed to C=O (15.4%) and C–OH/C–O–C (84.6%).23 These results indicate that catechol groups are successfully transferred from tannic acid molecules to the CDs surface during particle formation.
Fig. 2 (a) Entire XPS scanning spectrum of the CDs. XPS high-resolution survey scan of (b) C 1s and (c) O 1s of the CDs. |
It is interesting to ask why the as-prepared CDs possess many catechol groups on the surfaces, namely, what is the formation mechanism of CDs. The possible explanation is as follows: the polymerisation and condensation of tannic acid gives rise to soluble polymers. When concentration of the polymers reaches a critical supersaturation point, burst nucleation takes place. The core of the CDs with graphite structure was formed by this process. Then, tannic acid that has no carbonization will self-polymerize to form polymer onto the graphitic core under high temperature and high pressure, suggesting that CDs are wrapped outside with the polymer that contains large numbers of catechol groups.24
To further explore the optical properties of as-synthesized CDs, the absorption and detailed fluorescence study by using different excitation wavelengths were carried out. The UV-vis absorption spectrum of CDs in water shows an absorption band at ca. 440 nm (Fig. 3a). In the inset to Fig. 3a, a photograph of the dispersed CDs illuminated under UV light (365 nm) is shown. The bright blue fluorescence of CDs is strong enough to be easily seen with the naked eye. Interestingly, as excitation wavelength increases from 380 to 480 nm, the fluorescence wavelength changes little and shows a strong peak at 507 nm with optimal excitation wavelength at 440 nm (Fig. 3b). This special feature may result from less surface defects and more uniform size of CDs.25 The quantum yield of the CDs is estimated about 6.9% using rhodamine 101 as the reference, which is comparable to the value of previous reports.26
Typically, the phenolic hydroxyls would form complexes with Fe3+ ions due to coordination.27 Thus, the as-prepared CDs are a potential candidate for Fe3+ sensing. As shown in Fig. S4,† the initial dispersed CDs aggregate together and form a large assembly, as Fe3+ is introduced to the CDs solution. To further demonstrate such assembly was caused by Fe3+ instead of drying on grid, resonance light scattering (RLS) was used to monitor the interaction. As described in Fig. S5,† the RLS signals become more and more strong with the increase of added Fe3+. These in situ characterized data definitely demonstrate that the CDs assemble in solution with the assistance of Fe3+, leading to enhanced light scattering signal. As one of the most essential metal ions in biological systems, Fe3+ plays crucial roles in many physiological and pathological processes.28 Abnormal fluctuations (deficiency or overloading) of Fe3+ are the hallmarks of diseases.29,30 Thus, the determination of Fe3+ is fundamentally important.31,32
Firstly, we investigate the influence of pH on the fluorescence of CDs. As shown in Fig. S6,† an increment of pH value from 2 to 7 leads to increased fluorescence intensity, whereas further increase to 11 results in a gradual decrease, demonstrating the fluorescence intensity of CDs strongly depends on the pH value. We speculated that the change of pH might result in electrostatic doping/charging of the CDs and shifts the Fermi level, which is associated with the process of protonation and deprotonation of the carboxyl groups on the surface of CDs.33 Such observations are similar to those of CDs modified with hydroxyl and carboxylic/carbonyl moieties.34 To obtain lower detection limits and better sensing performances for both Fe3+ and OTC, the pH 7.0 citric acid–Na2HPO4 buffer system was selected in this work. The reaction time also affects the quenching effects. As described in Fig. S7,† the interactions can reach the balance at 20 min. As a consequence, 20 min of reaction time was appropriate for the sensing. Then the effects of different concentrations of sodium chloride on the fluorescence response of the system were evaluated. As shown in Fig. S8,† the change of ionic strength had no effect on the fluorescence intensity of the system, demonstrating high stability of the sensing system.
Under the conditions discussed above, the linear response range of the sensing system was measured. As shown in Fig. 4a, the fluorescence intensities of the CDs are highly sensitive to Fe3+ and decrease as the concentration of the analyte is increased. There is a good linear relationship (R2 = 0.992) between the F0/F and the concentrations of Fe3+ in the range from 0 to 5 μM (Fig. 4b) with a detection limit of 24.4 nM (signal-to-noise ratio of 3), which is lower than other previously reported values,24,35 indicating the higher sensitivity of the present sensing system, where F0 and F are the fluorescence intensities of CDs without and with Fe3+.
Interference test was carried out. It can be seen that those tested metal ions such as Co2+, Cu2+, Al3+, Cr3+ and so on are scarcely interfered (Fig. S9†), indicating the high selectivity.
In general, oxytetracycline hydrochloride, containing phenolic hydroxyl and enolic hydroxyl, could be chelate with Fe3+, which might reduce the influence of Fe3+ to the CDs fluorescence, and cause the recovery of fluorescence intensity of pre-quenched CDs. Thus, the present CDs–Fe3+ complex might be a potential candidate for turn-on OTC sensing. As we expected, the fluorescence intensity of quenched CDs is gradually recovered with the increment of OTC (Fig. 5a), and can be visually observed by naked eyes (inset of Fig. 5a). It can be seen from Fig. 5b, there is a good linear relationship (R = 0.997) between ΔF/F and the concentration of OTC in the range from 0.1 to 2.7 μM with a 22.8 nM detection limit, where ΔF is the recovered fluorescence intensity of CDs–Fe3+ system in the presence of OTC and F is the fluorescence intensity of the CDs–Fe3+.
Selectivity is a critical parameter to evaluate the performance of a fluorescent chemosensor. We first studied the fluorescence responses of the CDs–Fe3+ toward the potential interfering substances coexisting in milk sample, including structurally similar tetracycline group antibiotics and primary vitamins. As shown in Fig. 6a, other seven kinds of antibiotics, including penicillin (Pen), streptomycin (Str), erythromycin (Ery), chloramphenicol (Chl), tetracycline (Tet), doxycycline (Dox) and chlortetracycline (Chio) have very little effects on the CDs–Fe3+ system fluorescence. Then the influence of various primary vitamins was studied. As can be seen from Fig. 6b, these tested vitamins are scarcely interfered. The exclusive response of OTC probably results from the fact that the OTC contains more phenol hydroxyl, enol hydroxyl and carbonyl, which strengthens the coordination ability. However, the exact mechanism is not clear and needs further study. It should be noted here that the OTC can still be detected in the presence of the mixture of all possible coexistence antibiotics (Fig. 6c).
To further investigate the potential practical applications of this method, the sensing of OTC in real milk samples was performed. The results of recovery tests from 92.5 to 103% are satisfying (Table 1). The above results fully indicated the practicability and reliability of the proposed sensing platform for OTC detection in real samples.
Sample | Content of OTC/μM | OTC added/μM | OTC found/μM | Recovery (%) |
---|---|---|---|---|
1 | 0.13 ± 0.02 | 2 | 2.01 ± 0.06 | 94.0 ± 0.31 |
2 | 0.06 ± 0.03 | 2 | 1.99 ± 0.24 | 96.5 ± 1.15 |
3 | 0.06 ± 0.01 | 2 | 1.91 ± 0.08 | 92.5 ± 2.52 |
4 | 0.11 ± 0.03 | 2 | 2.14 ± 0.33 | 101.5 ± 4.1 |
5 | 0.05 ± 0.01 | 2 | 2.11 ± 0.12 | 103.0 ± 5.2 |
Footnote |
† Electronic supplementary information (ESI) available: Figures concerning AFM, Raman spectrum, FT-IR, TEM, RLS, effect of pH, effect of time, effect of ionic strength and selectivity of the Fe3+ sensor. See DOI: 10.1039/c4ra16456c |
This journal is © The Royal Society of Chemistry 2015 |