The introduction of lead and heavy-metal free ammunition to the market challenges the current protocol for gunshot residue (GSR) investigations, which focuses on the inorganic components. Future proofing GSR analysis requires the development and implementation of new methods for the collection and analysis of organic GSR (OGSR) into operational protocols. This paper describes the development and optimisation of an ultra high performance liquid chromatography method for the analysis of 32 compounds potentially present in OGSR. An artificial neural network was applied to predict the retention times of the target analytes for various gradients for rapid determination of optimum separation conditions. The final separation and analysis time for the 32 target analytes was 27 minutes with limits of detection ranging from 0.03 to 0.21 ng. The method was applied to the analysis of smokeless powder and samples collected from the hands of a shooter following the discharge of a firearm. The results demonstrate that the method has the potential for use in cases involving GSR.
The internationally accepted method for detection and analysis of GSR is scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX).3,17 This method depends on the presence of particles that are characteristic of GSR incorporating lead, antimony and barium, which originate from the primer. Due to the capability to selectively identify a single GSR particle based on morphology and elemental composition, SEM/EDX continues to be the method of choice for GSR identification in forensic casework and is unequalled by any other bulk analysis method.18,19 In the 1970s lead free (LF) and heavy-metal free (HMF) ammunitions were introduced to the market to decrease the exposure of frequent shooters to toxic gases and hazardous particulates released from the primer and the bullet itself.20 Although these ammunitions have been available for a few decades, recent legislative changes in some US states (e.g. California) prohibiting lead ammunition for hunting21 and the shift of other groups, most notable the US military, to lead free ammunition22 accentuate the increasing trend towards LF and HMF ammunition. The replacement of lead and/or heavy-metals has been accomplished by different processes, such as enclosing parts or the entire projectile with brass, copper or gilding metal, using a non-lead containing sintered metal for the fabrication of the projectile,23 and substituting lead, barium and antimony with other components such as diazodinitrophenol (DDNP).24,25 So far, different elemental profiles of spherical particles produced by LF and/or HMF ammunitions have been elucidated.20,23,26,27 These studies suggest that elemental profiles of LF and HMF GSR particulates are in consistency with the composition of the respective primers. However, identification of GSR particles formed by LF and HMF ammunition is problematic. The composition is not exclusive to firearm handling25 and IGSR particles from LF and HMF ammunition could potentially derive from other sources than firearms. Therefore, SEM/EDX analysis of IGSR from LF and HMF ammunition could possibly lead to false-negative results.23,26–28 Moreover, interpretation issues correlating to memory effects,29 GSR-like particles from environmental and occupational sources,30–32 and secondary or tertiary33–36 constitute additional challenges.
It is important to point out, that particle analysis by SEM/EDX continues to be the method of choice for GSR analysis as LF and HMF only constitutes a relatively small proportion of the ammunition on the market at present. However, the increasing trend towards LF and HMF ammunition and the associated limitations call for an adjustment of current Standard Operation Procedures (SOPs) for GSR investigation.
The analysis of organic gunshot residues (OGSR) originating from the propellant powder and primer provides additional information, complementary to that obtained by SEM-EDX analysis. Thus, incorporation of OGSR analysis to existing SOPs is beneficial. This incorporation must give consideration to the necessary sequencing of the organic and inorganic analyses, ensuring one does not impact on or preclude the subsequent testing.
When developing an analytical method, it is important to include both, OGSR from propellant powder as well as from primer mixtures to target a majority of the compounds potentially present.
OGSRs may be analysed using a variety of analytical methods including liquid chromatography (LC),37,38 gas chromatography (GC),39,40 micellar electrokinetic capillary electrophoresis (MECE),41 time-of-flight secondary ion mass spectrometry (TOF-SIMS),42 and desorption electrospray ionisation mass spectrometry (DESI-MS).43,44
Traditional LC method development consists of changing individual parameters one at a time, while keeping all others constant. This is a time consuming and challenging process given the large number of parameters and their possible interactions. An additional difficulty can be posed when a large number of compounds require separation, as in the case of OGSR analysis. An alternative route for rapid method development is the application of artificial neural networks (ANNs) which are predictive data-processing programs that mimic the way a human brain processes information. The processing units in ANNs consist of neurons, units, and nodes arranged in several interconnected layers.45 Multilayer perceptron (MLP) ANNs are constructed with three layers; the input layer, hidden layer and output layer.46 Each node of the input layer is associated with an experimental factor. The data is processed in the hidden layer by an activation function, whilst each node in the output layer is associated to a response.45 An advantage of ANNs against other predictive statistical network approaches is the capacity of an ANN to learn from a set of training examples that contain both the input and output data.45 A potential deficiency of ANNs is the possibility to over-learn or over-fit the network. In such cases, the ANN functions well with the training data points; however, its predictive capacity for other data points is sub optimal. Overlearning can be minimised by monitoring the error of predictions with a verification data set. Verification error that is greater than the training indicates over-fitting.47 ANNs have been applied to the separations of herbicides,48 cosmetic preservatives,49 benzodiazepines,46 organic explosives,50 peptides,51 and fatty acids methyl esters.52
This paper presents the rapid development and optimisation of a UHPLC method for the analysis of 32 OGSR target compounds with the aid of an ANN. To the best of our knowledge, this is the first publication showing the application of an ANN to OGSR.
Compound | Abbreviation | Function | Standard concentration | Source |
---|---|---|---|---|
a Ref. 2, 13, 23, 27, 37 and 57. b Cerilliant – Round Rock, TX, USA; AccuStandard – New Hssaven, CT, USA; ChemService – West Chester, PA, USA. Dr Ehrenstorfer GmbH – Augsburg, Bavaria, Germany. | ||||
Nitroglycerin | NG | Propellant | 1000 μg mL−1 in ACN | Cerilliant |
1,2-Dinitroglycerin | 1,2-DNG | Explosive | 100 μg mL−1 in ACN | AccuStandard |
1,3-Dinitroglycerin | 1,3-DNG | Explosive | 100 μg mL−1 in ACN | AccuStandard |
Nitroguanidine | NGU | Flash suppressor | 100 μg mL−1 in MeOH | AccuStandard |
2,4,6-Trinitrotoluene | TNT | Explosive, sensitiser | 1000 μg mL−1 in ACN | ChemService |
2,3-Dinitrotoluene | 2,3-DNT | Flash suppressor | 99.5% certified purity | Dr Ehrenstorfer GmbH |
2,4-Dinitrotoluene | 2,4-DNT | Flash suppressor | 1000 μg mL−1 in ACN | ChemService |
2,6-Dinitrotoluene | 2,6-DNT | Flash suppressor | 1000 μg mL−1 in ACN | ChemService |
3,4-Dintirotoluene | 3,4-DNT | Flash suppressor | 1000 μg mL−1 in MeOH | ChemService |
4-Amino-2,6-dinitrotoluene | 4-A-2,6-DNT | Flash suppressor | 1000 μg mL−1 in ACN | ChemService |
3-Nitrotoluene | 3-NT | Explosive, flash suppressor | 1000 μg mL−1 in ACN | ChemService |
1,3,5-Trinitrobenzene | TNB | Explosive | 1000 μg mL−1 in ACN | ChemService |
1,3-Dinitrobenzene | 1,3-DNB | Explosive | 1000 μg mL−1 in ACN | ChemService |
Nitrobenzene | NB | Explosive | 1000 μg mL−1 in ACN | ChemService |
N,N′-Diphenylurea | N,N′-DPU | Stabiliser, plasticiser | 97.5% certified purity | Dr Ehrenstorfer GmbH |
Methyl centralite | MC | Stabiliser, plasticiser | 100 μg mL−1 in 50% ACN | AccuStandard |
Ethyl centralite | EC | Stabiliser, plasticiser | 500 μg mL−1 in ACN | AccuStandard |
1,3-Benzenediol | Resorcinol | Stabiliser, plasticiser | 100 μg mL−1 in MeOH | AccuStandard |
Dimethyl phthalate | DMP | Plasticiser | 1000 μg mL−1 in MeOH | AccuStandard |
Diethyl phthalate | DEP | Plasticiser | 100 μg mL−1 in MeOH | AccuStandard |
Dibutyl phthalate | DBP | Plasticiser | 99% certified purity | ChemService |
Diphenylamine | DPA | Stabiliser | 1000 μg mL−1 in MeOH | AccuStandard |
2-Nitrodiphenylamine | 2-NDPA | Stabiliser (DPA derivative) | 100 μg mL−1 in ACN | AccuStandard |
4-Nitrosodiphenylamine | 4-nDPA | Stabiliser (DPA derivative) | 99% certified purity | ChemService |
N-Nitrosodiphenylamine | N-nDPA | Stabiliser (DPA derivative) | 1000 μg mL−1 in MeOH | AccuStandard |
2,4-Dinitrodiphenylamine | 2,4-DNDPA | Stabiliser (DPA derivative) | 97.5% certified purity | Dr Ehrenstorfer GmbH |
Ethylene glycol dinitrate | EGDN | Explosive | 100 μg mL−1 in ACN | AccuStandard |
Pentaerythritol tetranitrate | PETN | Explosive, sensitiser | 1000 μg mL−1 in ACN | ChemService |
Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine | HMX | Explosive | 1000 μg mL−1 in ACN![]() ![]() ![]() ![]() |
AccuStandard |
Hexahydro-1,3,5-trinitro-1,3,5-triazine | RDX | Explosive | 1000 μg mL−1 in ACN | ChemService |
2,4,6-Trinitrophenylmethyl nitramine | Tetryl | Sensitiser | 1000 μg mL−1 in ACN | ChemService |
Diazodinitrophenol | DDNP | Initiating explosive | 100 μg mL−1 in ACN | AccuStandard |
The identities of the compounds detected by UHPLC analysis with UV detection were confirmed by mass spectrometric detection using an Agilent Technologies 6490 triplequad mass spectrometer controlled by MassHunter software version B.06.00 (Agilent Technologies). The mass spectrometer was connected to an atmospheric pressure chemical ionisation (APCI) ion source (G1947 A/B) from Agilent Technologies. Multiple reaction monitoring (MRM) mode was used, which provides a high degree of certainty in identifying compounds based on their precursor-to-product transitions. The conditions for the MRM of the compounds were optimised either using the Optimizer Software (Agilent Technologies) or manually and are shown in Table 2. The most abundant and specific ions were chosen.
Compound | Ionization mode | Precursor ion [m/z] | Product ions [m/z] |
---|---|---|---|
2-Naphthol | APCI+ | 145.07 | 104.0, 62.9, 60.1 |
DPA | APCI+ | 170.1 | 152.1, 93.0, 78.0 |
N-nDPA | APCI+ | 199.0 | 181.0, 128.0, 77.0 |
4-nDPA | APCI+ | 199.09 | 182.0, 128.0, 126.9 |
2-NDPA | APCI+ | 215.08 | 197.0, 180.9, 180.0 |
EC | APCI+ | 269.16 | 148.1, 119.9, 92.1 |
MC | APCI+ | 241.14 | 134.1, 106.0, 93.1 |
NG | APCI− | 226.0 | 195.9, 133.9, 75.9 |
DNG | APCI− | 181.01 | 85 |
DNG | APCI+ | 183.03 | 77.0, 51.2 |
All 33 compounds (32 OGSR and one internal standard) were run individually in duplicates at the five different gradients to provide the training data (average retention times) for the ANN. Aliquots of the stock standards were diluted for UHPLC analysis in MeOH:
ACN (1
:
1) to generate solutions at working concentrations of 20 ppm with 20 ng injected. Two gradients at 0.7% per min and 4.6% per min were used to provide verification data in order to examine the suitability of the ANN for the prediction of the average retention times.
Ammunition number | Caliber | Ammunition manufacturer (country of origin) | Firearm model (country of origin) |
---|---|---|---|
1 | WinClean 45 (LF) | Winchester (Australia) | Colt (USA) |
2 | 45 Auto CP | Winchester (Australia) | Colt (USA) |
3 | 44 Rem Magnum | PMC (USA) | Smith & Wesson model 629-4 (USA) |
44 Rem Magnum | Winchester (Australia) | Smith & Wesson model 629-4 (USA) | |
4 | 9 mm Parabellum | Blazer, CCI (USA) | Beretta model 902FS (Italy) |
5 | 357 Magnum | Winchester (Australia) | Smith & Wesson revolver model 686-3 (USA) |
357 Magnum | PMC (USA) | Smith & Wesson revolver model 686-3 (USA) | |
6 | 22 LR high velocity | Remington (USA) | Sport King (USA) |
22 LR high velocity | Winchester (Australia) | Sport King (USA) | |
22 LR high velocity | Remington (USA) | Rifle 70 (Marlin, USA) | |
22 LR high velocity | Winchester (Australia) | Rifle 70 (Marlin, USA) | |
7 | 40 S&W WinClean (LF) | Winchester (Australia) | Glock (Austria) |
8 | 40 S&W | Winchester (Australia) | Glock (Austria) |
9 | 12 gauge (SuperX) | Winchester (Australia) | Shotgun, model 870 (Remington, USA) |
5 mL MTBE were added to the swab in a scintillation vial. After a 5 min sonication, the solvent was removed under a steady stream of nitrogen gas and the sample reconstituted in 196 μL of mobile phase and 4 μL internal standard was added. The sample was filtered using a 0.2 μm syringe filter prior to analysis by UHPLC.
Initially, the ANN training data consisted of five linear gradient slopes as the independent input variable, whilst the average of the duplicate retention times for each of the 33 standards was used as the dependent output variables. These 165 experimental points were used to construct a suitable ANN architecture to adequately model the response surface. An iterative heuristic process resulted in a multi-layer perceptron network with one input node, 19 nodes in the hidden layer, and 33 nodes in the output layer representing the retention times of the 33 compounds (Fig. 2).
This network was used to predict retention times for all compounds within the experimental space with gradient increments of 0.1% per min. The minimum peak pair difference (the retention time difference between two closest peaks) was calculated and a response resolution plot constructed (Fig. 3). The highest point on the response resolution plot (0.7% per min MeOH) represented the best performing gradient in terms of resolution. However, the predicted analysis time was 54.0 min, which is of limited practical use. Therefore a compromise between resolution and runtime was made, with the gradient at 4.6% per min offering a suitable outcome in terms of run time and resolution. This gradient separated 22 compounds, whilst 11 compounds co-eluted.
The possibility of overfitting was eliminated by running the individual standards at gradients of 0.7% per min and 4.6% per min for use as verification data points for retraining of the ANN. Using the same process as described before, the ANN with the smallest error was again determined to be a MLP network with 1:
1–19–33
:
33 architecture. This together with the high correlation (R2 = 0.999) between observed and predicted retention times demonstrated that the ANN adequately described the response surface. Differences between measured and predicted retention times were in the range between 0–7.44%.
The initial MeOH concentration of the mobile phase had the strongest influence on the first eight peaks; RDX and 1,3-DNG coeluted at 5% MeOH; whilst EGDN and HMX coeluted at 15% MeOH. All of the first eight peaks were baseline separated and clearly distinguishable at 10% MeOH. Increasing the temperature to 43 °C further increased the resolution due to improved mass transfer with 27 peaks separated. Two isocratic steps were then introduced to separate tetryl, TNT, DMP and the DNT isomers. Separation of the 33 target analytes is shown in Fig. 4.
Compound | Average retention time [min] | Capacity factor, k′ | Sensitivity | |
---|---|---|---|---|
LOD [ng] | LOQ [ng] | |||
a Internal standard. | ||||
NG | 10.55 | 18.9 | 0.14 | 0.43 |
1,2-DNG | 3.134 | 4.91 | 0.085 | 0.26 |
1,3-DNG | 2.693 | 4.08 | 0.068 | 0.21 |
NGU | 0.5430 | 0.0200 | 0.11 | 0.33 |
TNT | 13.26 | 23.9 | 0.075 | 0.23 |
2,3-DNT | 16.07 | 29.3 | 0.041 | 0.12 |
2,4-DNT | 16.16 | 29.5 | 0.13 | 0.40 |
2,6-DNT | 15.60 | 28.4 | 0.069 | 0.21 |
3,4-DNT | 14.51 | 26.34 | 0.062 | 0.18 |
m-NT | 18.81 | 34.5 | 0.041 | 0.12 |
4-A-2,6-DNT | 13.76 | 25.0 | 0.044 | 0.13 |
TNB | 5.913 | 10.1 | 0.078 | 0.24 |
m-DNB | 7.018 | 12.2 | 0.065 | 0.20 |
NB | 8.593 | 15.1 | 0.068 | 0.20 |
DPA | 23.30 | 42.9 | 0.091 | 0.28 |
2-NDPA | 24.77 | 45.7 | 0.035 | 0.10 |
4-nDPA | 20.99 | 38.6 | 0.059 | 0.18 |
N-nDPA | 22.67 | 41.7 | 0.080 | 0.24 |
2,4-DNDPA | 23.94 | 44.2 | 0.23 | 0.71 |
Resorcinol | 1.548 | 1.92 | 0.11 | 0.32 |
EC | 25.05 | 46.3 | 0.11 | 0.32 |
MC | 22.80 | 42.0 | 0.079 | 0.24 |
RDX | 2.323 | 3.37 | 0.079 | 0.24 |
HMX | 3.706 | 5.97 | 0.075 | 0.23 |
PETN | 20.17 | 37.0 | 0.10 | 0.31 |
Tetryl | 12.51 | 22.6 | 0.054 | 0.16 |
EGDN | 3.435 | 5.48 | 0.087 | 0.26 |
DMP | 14.91 | 27.1 | 0.039 | 0.12 |
DEP | 21.51 | 39.6 | 0.13 | 0.40 |
DBP | 26.38 | 48.8 | 0.034 | 0.11 |
N,N′-DPU | 19.86 | 36.5 | 0.034 | 0.10 |
DDNP | 1.848 | 2.48 | 0.21 | 0.65 |
2-Naphthola | 18.16 | 33.2 | N/A | N/A |
Various OGSR were detected in the unburned smokeless powders and hand swab samples. All UHPLC-UV detections were confirmed by tandem mass spectrometry using the above outlined method. Each of the tested powders included NG, thus was a double based powder. NG was found in 62.2% of the hand swab samples, 1,2-DNG in 66.7% and 1,3-DNG in 34.6%. The stabilisers DPA, EC and MC were detected in 47.4%, 73.5%, and 72.9% of the hand swab samples respectively. The fact that EC and MC were detected in approximately 3/4 of the hand swab samples after firing ammunition is of high importance since MC and EC are considered to be the most characteristic compounds for OGSR.37,62 DPA alone is not characteristic for OGSR. However, when detected in combination with its derivates, it is considered as indicative for OSGR.63 DPA derivates detected included N-nDPA (5.1%), 4-nDPA (6.4%), and 2-NDPA (75.6%). The results show, that the developed method can provide vital information in the investigation of a firearm related event. Additionally, the combined detection of the various compounds increases the evidential value of the developed method for OSGR investigation.
Moreover, the method was able to quantify the compounds of interest present in smokeless powder samples and hand swabs after only a single cartridge was discharged. For the different powders tested before and after shooting, differences in the chemical composition could be found and profiles for each powder established. The method has therefore the potential to distinguish between different ammunitions based on their varying composition and potentially link ammunition to the OGSR found on the hands of a shooter.
The concentrations of the detected compounds were relatively low (in the low ng range), which is in consistency with previous reported concentration2,64 and underlines the significance of a sensitive method as developed here.
It is important to consider, that swabs were used in order to collect OGSR from the hands of a shooter. Studies comparing swabbing of OGSR to other commonly applied collection techniques can inform on which technique is most suitable for OGSR collection. Applying the most suitable collection technique might ultimately improve the collection efficiency and increase the levels of OGSR detected. Since police commonly uses GSR stubs in order to collect IGSR from hands, it should be tested whether OGSR extracted from GSR stubs can be detected using the developed method.
In order to implement such a method in routine casework additional research is required along with individual laboratory validation studies in order to ensure that quality standards for OGSR investigations are met.