Issue 18, 2014

Lab-on-a-drop: biocompatible fluorescent nanoprobes of gold nanoclusters for label-free evaluation of phosphorylation-induced inhibition of acetylcholinesterase activity towards the ultrasensitive detection of pesticide residues

Abstract

A simple, sensitive, selective, and “lab-on-a-drop”-based fluorimetric protocol has been proposed using biocompatible fluorescent nanoprobes of gold nanoclusters (AuNCs) for the label-free evaluation of the catalytic activity and phosphorylation of acetylcholinesterase (AChE) under physiologically simulated environments. Protein-stabilized AuNCs were prepared and mixed with acetylthiocholine (ATC) serving as “a drop” of fluorimetric reaction substrate. The AChE-catalyzed hydrolysis of ATC releases thiocholine to cause the aggregation of the AuNCs towards a dramatic decrease in fluorescence intensities, which could be curbed by the phosphorylation-induced inhibition of AChE activity when exposed to organophosphorus compounds (OPs). The reaction procedures and conditions of AChE catalysis and phosphorylation were monitored by fluorimetric measurements and electron microscopy imaging. Moreover, a selective and ultrasensitive fluorimetric assay has been tailored for the detection of pesticide residues using dimethyl-dichloro-vinyl phosphate (DDVP) as an example. Investigation results indicate that the specific catalysis and irreversible OP-induced phosphorylation of AChE, in combination with sensitive fluorimetric outputs could facilitate the detection of total free OPs with high selectivity and sensitivity. A linear concentration of DDVP ranging from 0.032 nM to 20 nM could be obtained with a detection limit of 13.67 pM. Particularly, pesticide residues of DDVP in vegetable samples were quantified down to ∼36 pM. Such a label-free “lab-on-a drop”-based fluorimetry may promise wide applications for the evaluation of the physiological catalytic activity of various enzymes (i.e., cholinesterase), and especially for monitoring the direct phosphorylation biomarkers of free OPs towards rapid and early warning, and accurate diagnosis of OP exposure.

Graphical abstract: Lab-on-a-drop: biocompatible fluorescent nanoprobes of gold nanoclusters for label-free evaluation of phosphorylation-induced inhibition of acetylcholinesterase activity towards the ultrasensitive detection of pesticide residues

Article information

Article type
Paper
Submitted
12 May 2014
Accepted
27 Jun 2014
First published
27 Jun 2014

Analyst, 2014,139, 4620-4628

Author version available

Lab-on-a-drop: biocompatible fluorescent nanoprobes of gold nanoclusters for label-free evaluation of phosphorylation-induced inhibition of acetylcholinesterase activity towards the ultrasensitive detection of pesticide residues

N. Zhang, Y. Si, Z. Sun, S. Li, S. Li, Y. Lin and H. Wang, Analyst, 2014, 139, 4620 DOI: 10.1039/C4AN00855C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.