Issue 6, 2013

A simple and sensitive LC-ICP-MS method for the accurate determination of vitamin B12 in fortified breakfast cereals and multivitamin tablets

Abstract

A sensitive liquid chromatographic (LC) method coupled with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the determination of vitamin B12. The method was based on efficient isocratic separation with a mobile phase consisting of 20 mmol L−1 ethylenediaminetetraacetic acid (EDTA) in 25/75 methanolwater mixture (volume fractions) operating at a flow rate of 0.2 mL min−1. After LC separation, ionic cobalt (Co), cyanocobalamin, methylcobalamin, and hydroxocobalamin were measured as 59Co by ICP-MS. For Co as cyanocobalamin, the analyte of interest of this work, the method has shown good repeatability with relative standard deviation (RSD) of 3% for ten measurements and excellent linearity between 0.1 ng g−1 and 100 ng g−1 (linear regression, r2 > 0.999). The limit of detection (LOD) for cyanocobalamin was found to be less than 1 ng g−1, which permits the method to be employed for the determination of ultra-trace concentrations of vitamin B12 in various types of dietary supplements and fortified food products. Cyanocobalamin in aqueous solution was found to decompose under the ambient light of the laboratory; therefore, dark room conditions are required for the determination of vitamin B12 in the form of cyanocobalamin to minimize the photon-induced decomposition. To determine total Co in a commercial high-purity cyanocobalamin using direct ICP-MS measurement as part of an effort to characterize the chemical for use as a calibrant, it was observed that quantitative measurement of Co was achieved only through a complete acid digestion. The method was applied to the determination of vitamin B12 in Standard Reference Material (SRM) 3233 Fortified Breakfast Cereal. SRM 3280 Multivitamin/Multielement Tablet was used for quality assurance of the cereal sample measurements. The vitamin B12 value of (0.187 ± 0.016) mg kg−1 found in SRM 3233 was comparable to (0.219 ± 0.066) mg kg−1 obtained by Grocery Manufacturers Association's Food Industry Analytical Chemists Committee (FIACC) using microbiological assay. The (4.38 ± 0.05) mg kg−1 of vitamin B12 found in quality assurance samples of SRM 3280 was in good agreement with the certified values of (4.8 ± 1.0) mg kg−1.

Graphical abstract: A simple and sensitive LC-ICP-MS method for the accurate determination of vitamin B12 in fortified breakfast cereals and multivitamin tablets

Supplementary files

Article information

Article type
Paper
Submitted
26 Dec 2012
Accepted
10 Apr 2013
First published
10 Apr 2013

J. Anal. At. Spectrom., 2013,28, 901-907

A simple and sensitive LC-ICP-MS method for the accurate determination of vitamin B12 in fortified breakfast cereals and multivitamin tablets

C. S. Kesava Raju, L. L. Yu, J. E. Schiel and S. E. Long, J. Anal. At. Spectrom., 2013, 28, 901 DOI: 10.1039/C3JA30383G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements