A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min−1

Abstract

Accurate measurement of workplace respirable dust concentration is an essential step in eliminating lung disease in any occupational setting. In the United States (U.S.) coal mining industry, this measurement process has relied upon a personal sampler that includes a 10 mm Dorr-Oliver (DO) nylon cyclone operated at a flow rate of 2.0 L min−1 to collect a respirable dust sample. Dust concentrations measured with this sampler are multiplied by 1.38, which was empirically derived, to convert them to measurements approximating the United Kingdom British Medical Research Council (BMRC) definition of respirable dust upon which the health effects of coal mine dust are based. The International Organization for Standardization (ISO) subsequently refined the respirable dust definition and the U.S. National Institute for Occupational Safety and Health (NIOSH) 1995 Criteria for a Recommended Standard presented a conversion multiplier of 0.857 to apply to the 2.0 L min−1DO (in addition to the1.38 multiplier) to obtain equivalent ISO concentrations, as approximated by the 1.7 L min−1DO. However, the conversion multiplier 0.857 was derived indirectly from a limited size distribution data set rather than a direct comparison of the DO samplers. The present analysis focuses on providing a more accurate conversion multiplier derived from direct comparisons of the 2.0 L min−1 (with 1.38 BMRC equivalency multiplier) and 1.7 L min−1DO cyclones. A weighted linear regression analysis of this database suggests that a more accurate estimate of the conversion multiplier is 0.815.

Graphical abstract: A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min−1

Supplementary files

Article information

Article type
Paper
Submitted
13 Oct 2008
Accepted
12 Dec 2008
First published
19 Jan 2009

J. Environ. Monit., 2009,11, 684-689

A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min−1

S. J. Page and J. C. Volkwein, J. Environ. Monit., 2009, 11, 684 DOI: 10.1039/B817922K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements