Steffen
Jockusch
a,
Angel A.
Martí
a,
Nicholas J.
Turro
*ab,
Zengmin
Li
bc,
Xiaoxu
Li
c,
Jingyue
Ju
bc,
Nathan
Stevens
d and
Daniel L.
Akins
d
aDepartments of Chemistry, Columbia University, New York, NY 10027
bDepartments of Chemical Engineering, Columbia University, New York, NY 10027
cColumbia Genome Center, Columbia University College of Physicians and Surgeons, New York, NY 10032
dDepartment of Chemistry, City College, City University of New York, NY 10031
First published on 21st March 2006
We report the design, synthesis, and characterization of a molecular beacon (MB) consisting of two fluorescent dyes (Alexa 488 and RedX) for DNA and RNA analysis. In the absence of the target DNA or RNA the MB is in its stem-closed form and shows efficient energy transfer from the donor (Alexa) to the acceptor (RedX), generating mostly fluorescence from RedX. In the presence of the complementary target DNA the MB opened efficiently, hybridizes with the target DNA, and energy transfer is blocked in the stem-open form. This attachment to the target generates a fluorescence signature, which is clearly distinguishable from the fluorescence signature of the stem-closed form, allowing for ratiometric analysis of the fluorescence signal. In addition to steady-state fluorescence analysis, time resolved fluorescence (ps time range) and fluorescence depolarization studies were performed. We show that fluorescence lifetime and fluorescence depolarization measurements are useful analytical tools to optimize the MB design.
![]() | ||
| Scheme 1 Schematic representation of a dye–quencher MB and two-dye MB. | ||
![]() | ||
| Scheme 2 Structure of the two-dye MB, Alexa–MB–RedX, and the target DNA. The two dyes, Alexa and RedX, are covalently linked at the 5′ and 3′ position, respectively. | ||
In an effort to overcome these limitations of the classical MB, a new type of MB has been reported which uses a quencher that itself is fluorescent (Scheme 1, right).9 This MB contains two fluorophores, a donor dye (coumarin) and an acceptor dye (6-carboxyfluorescein), which are covalently attached at opposite ends of the stem. In the stem-closed form the coumarin fluorescence is quenched by the acceptor dye, 6-carboxyfluorescein, through FRET, generating fluorescence of the acceptor dye, which is at a different wavelength than the fluorescence of the donor dye. In the stem-open form FRET is negligible and mainly the fluorescence of coumarin is observed.9 It was demonstrated that this two-dye MB shows a higher sensitivity than conventional dye–quencher MBs. Moreover, the change in fluorescence wavelength upon detection of target allows for a ratiometric fluorescence analysis. Ratiometric analysis is usually superior compared to intensity based measurements,9,10 such as in conventional dye–quencher MB. Furthermore, ratiometric analysis is less dependent on MB concentration fluctuations, photobleaching of the dye, optical geometry and other environmental factors.9 Other MBs that employ pyrenes as fluorophores for ratiometric analysis have been reported. These MBs switch their fluorescence wavelength by exploiting monomer or excimer photoluminescence in the stem-open and stem-closed form, respectively.11,12
In this paper we report on a MB, which contains two fluorophores, the donor dye Alexa 488 and the acceptor dye RedX, attached at opposite ends of the oligonucleotide (Scheme 2). The selected stem consists of six G–C base pairs, because G–C base pairs are known to be more stable than A–U base pairs.13 This higher stability of the stem reduces the non-specific opening of the MB in the absence of target. The loop sequence was selected based on our interest to study sensorin mRNA in neurons. We selected as a target the 271–293 region of sensorin mRNA, which is present in the sensory neurons of the mollusk Aplysia Californica.14 This loop sequence presents little secondary structure. Therefore, competition with the sensorin sequence due to self-complementarity is not expected. The light absorber, the donor dye Alexa,15 was selected based on its favorable excitation wavelength (488 nm), which can be provided by an argon-ion laser available in most fluorescence microscopes. In addition, compared to previously reported two-color MBs,9,11,12 which used UV absorbing chromophores, the longer excitation wavelength, since it avoids direct excitation of biological molecules, is more attractive for biological applications.
The MB contains modified 2′O-methyloligoribonucleotides that are known to hybridize more efficiently, have higher stability, and are more resistant to enzymatic degradation when compared to unmodified deoxyribonucleotides.16–18
The single dye MBs, Alexa–MB and MB–RedX, were synthesized analogues to Alexa–MB–RedX.
![]() | (1) |
![]() | ||
| Fig. 1 Fluorescence spectra after excitation of Alexa–MB–RedX (1 µM) in aqueous buffer solutions (20 mM Tris, 60 mM MgCl2), 500 mM NaCl, pH = 7.0, at 488 nm in the absence (a) and presence (b) of target DNA (10 µM). | ||
For practical applications of the MB, a high contrast ratio is desired to detect target DNA or RNA sequences. However, the contrast ratio is reduced by the residual emission of the donor dye (e.g. Alexa) in the stem-closed form and the residual emission of the acceptor dye (e.g. RedX) in the stem-open form.
To investigate the residual emissions in detail and ultimately improve the MB design, time-resolved fluorescence experiments were performed. Laser excitation at 488 nm (150 fs pulse width) of the stem-closed form yielded time-resolved fluorescence spectra and kinetic decay traces using a streak-camera. Fig. 2 shows the fluorescence decay traces of the donor dye (Alexa) (a,b) and the acceptor dye (RedX) (c,d) at a short (b,d) and a long (a,c) observation time window. Excitation of Alexa generated a fluorescence, which decayed multi-exponentially (see Table 1). The fastest component of the decay (τ3 < 50 ps) (Fig. 2b), within our instruments response, is attributed to the energy transfer quenching of Alexa by RedX (Fig. 2f). The longer components (τ2 and τ1) contribute to most of the fluorescence (∼98%). To ascertain if these slow decay components are caused by rate limiting energy transfer quenching (slow generation of excited states of RedX) or are caused by defective MBs, where energy transfer quenching is hindered, time-resolved fluorescence experiments were also performed on a stem-closed MB which contains only Alexa, but no RedX (Alexa–MB). Fig. 3c shows that the fluorescence decay of Alexa–MB in the stem-closed form is very similar to the slow component decay of Alexa–MB–RedX (Fig. 3a). In addition, a comparison of the fluorescence lifetimes reveals that τ2 and τ1 as well as the intensity contributions are similar for both MBs (Table 1). Therefore, we conclude that the slow decay components (τ2 and τ1) of the “stem-closed” Alexa–MB–RedX are not caused by slow energy transfer and does not generate excited states of RedX. We interpret our observations as suggesting one or more of the following: (i) energy transfer in a small fraction of the sample is hindered, probably because some of the MBs opened without the presence of target; (ii) some conformations of the stem-closed MB sterically hinder energy transfer; and (iii) some of the MBs do not contain a quencher. We note further that the fluorescence decays of Alexa in the stem-open MBs, i.e., Alexa–MB–RedX (Fig. 3b) and Alexa–MB (d), as well as that for the stem-closed Alexa–MB (c) are similar as expected (see also Table 1).
| τ 1/ns (%)a | τ 2/ns (%)a | τ 3/ns (%)a | P AA b | P AR c | P RR d | |
|---|---|---|---|---|---|---|
| a Fluorescence lifetimes (τ) and corresponding fluorescence contribution (%). b Polarization values (PAA) for excitation of Alexa and emission of Alexa. c Polarization values (PAR) for excitation of Alexa and emission of RedX. d Polarization values (PRR) for excitation of RedX and emission of RedX. | ||||||
|
3.0 (39%) | 0.39 (61%) | <0.05 (∼2%) | 0.12 | 0.11 | 0.28 |
|
2.2 (73%) | 0.55 (27%) | — | 0.16 | 0.10 | 0.25 |
|
3.0 (30%) | 0.38 (70%) | — | 0.10 | — | — |
|
3.1 (66%) | 0.34 (34%) | — | 0.14 | — | — |
|
2.4 (74%) | 0.87 (26%) | — | — | — | 0.28 |
|
2.2 (82%) | 0.70 (18%) | — | — | — | 0.25 |
![]() | ||
| Fig. 2 Fluorescence decay of Alexa (a,b) monitored from 510 to 530 nm and RedX (c,d) monitored at 580 to 620 nm after laser excitation of Alexa at 488 nm (150 fs pulses) in aqueous buffer solutions of Alexa–MB–RedX (1 µM). The temporal instruments response is shown in (e,f). | ||
![]() | ||
| Fig. 3 Fluorescence decay of Alexa monitored from 510 to 530 nm after laser excitation of Alexa at 488 nm (150 fs pulses) in aqueous buffer solutions of Alexa–MB–RedX (a,b) and Alexa–MB (c,d) in the absence (a,c) and presence (b,d) of target DNA (10 µM). | ||
Steady-state fluorescence spectra of the stem-closed Alexa–MB (absence of target) and stem-open Alexa–MB (presence of target) showed strong fluorescence of Alexa. However, the fluorescence intensity of the stem-open form (presence of target) increased approximately 35% compared to the stem-closed form (see electronic supplementary information (ESI), Fig. S2†). This is consistent with time-resolved fluorescence experiments (Fig. 3), where the decay of Alexa in the stem-closed form of Alexa–MB (c) is slightly faster than in the stem-open form (d). This quenching effect of Alexa in the stem-closed form is probably caused by guanosine residues. Because Alexa is covalently attached to dC, in the stem-closed form dG is in close proximity due to hybridization with dC (Scheme 2) and probably causing some quenching. In the stem-open form the guanosine residue is separated from Alexa and an approximately 35% stronger fluorescence is observed (see ESI, Fig. S2†). Similar quenching effects have been reported for fluorescent dye linked oligonucleotides.19–21
The fluorescence lifetime of the acceptor dye, RedX, was examined. Fig. 4 shows that the fluorescence decays of RedX in the stem-open Alexa–MB–RedX (b), stem-open MB–RedX (d), and stem-closed MB–RedX (c) are very similar (see also Table 1). However, the fluorescence of RedX decayed slightly faster in the stem-closed Alexa–MB–RedX (a). Probably some quenching of excited states of RedX by Alexa occurred due to the close proximity of both dyes. Although both dyes, Alexa and RedX, are known to have single exponential decays in free solution,22 it is frequently reported that dyes covalently bound to DNA or RNA show multi-exponential fluorescence decays due to inhomogeneity and nucleotide interactions.23
![]() | ||
| Fig. 4 Fluorescence decay of RedX monitored from 580 to 620 nm after laser excitation at 488 nm (150 fs pulses) in aqueous buffer solutions of Alexa–MB–RedX (a,b) and Alexa–MB (c,d) in the absence (a,c) and presence (b,d) of target DNA (10 µM). | ||
Fluorescence depolarization studies provided further information on the photophysics of the MBs. Table 1 shows the polarization values (P) for the individual fluorophores and energy transfer components. The P values were determined by exciting one fluorophore with linearly polarized light and analyzing the depolarization of the fluorescence at different wavelength corresponding to the individual fluorophores. A fluorophore can lose its polarization by rotation during its fluorescence lifetime.24 The similar polarization values of Alexa (PAA) for the MBs are in agreement with their similar fluorescence lifetimes (Fig. 3). Fluorescence polarization transfer from Alexa to RedX was observed in the stem-closed Alexa–MB–RedX (PAR = 0.11). This indicates efficient fluorescence energy transfer. The polarization values of RedX (PRR) for all four samples (stem-closed and stem-open Alexa–MB–RedX and MB–RedX) are very similar, which is consistent with the similar fluorescence lifetimes (Fig. 4).
To investigate the photophysical properties of the stem-open MBs an excess (10 fold) of target DNA to the MB was used in the experiments described above. This excess was used to ensure that the interference of stem-closed MB is negligible. The target DNA concentration dependence on the MB opening equilibrium was investigated in detail and is described in the ESI, Fig. S3.† The MB showed a high sensitivity towards the target DNA. At equimolar concentrations of target and MB more than 50% of the MB opened to hybridize with the target. In control experiments using a non-complementary target sequence, no opening of the stem-closed MB was observable even at a large excess of non-complementary target (see ESI, Fig. S4†).
Footnote |
| † Electronic supplementary information (ESI) available: Details of the synthesis of the MB, UV-Vis absorption spectra of the MBs (Fig. S1), fluorescence spectra of Alexa–MB and MB–RedX (Fig. S2), target DNA concentration dependence (Fig. S3), and no interaction of the MB with non-complementary target DNA (Fig. S4). See DOI: 10.1039/b600213g |
| This journal is © The Royal Society of Chemistry and Owner Societies 2006 |