Comparison of the solid sampling techniques laser ablation-ICP-MS, glow discharge-MS and spark-OES for the determination of platinum group metals in Pb buttons obtained by fire assay of platiniferous ores

Abstract

This work reports on the performance of a new Pb fire assay procedure for the extraction of Au, Cu, Ir, Ni, Pd, Pt, Rh and Ru from platiniferous ores, followed by the direct analysis of the Pb buttons thus obtained by means of three solid sampling techniques (spark-OES, LA-ICP-DRC-MS and GD-sector field-MS), therefore avoiding the process of cupellation. It can be concluded that this working scheme allows the reliable analysis of different ore materials, except for Ni and Ir, for which no quantitative extraction was achieved. The preparation of the Pb buttons using large masses of the ores permitted us to obtain representative and homogeneous buttons, resulting in acceptable precision values (typically RSD values ranged between 2–5% for spark-OES and GD-MS, and between 4–10% for LA-ICP-MS), while the simple composition of these buttons (≥99% Pb) enabled the preparation of matrix-matched standards for calibration. In general terms, all these techniques perform in a satisfactory way, although they showed different strengths and weaknesses. While spark-OES provides the highest sample throughput, its detection limits are not always sufficiently low for some analytes (Au, Ir, Pt). It is demonstrated that these detection limits can be further decreased by using techniques based on mass spectrometry (LA-ICP-MS and, particularly, GD-MS), although the use of an instrumental configuration capable of dealing with spectral overlap is required, namely a dynamic reaction cell pressurized with NH3 in the case of LA-quadrupole ICP-MS and a double-focusing sector field mass analyser in the case of GD-MS.

Graphical abstract: Comparison of the solid sampling techniques laser ablation-ICP-MS, glow discharge-MS and spark-OES for the determination of platinum group metals in Pb buttons obtained by fire assay of platiniferous ores

Article information

Article type
Paper
Submitted
03 Mar 2006
Accepted
15 May 2006
First published
06 Jun 2006

J. Anal. At. Spectrom., 2006,21, 899-909

Comparison of the solid sampling techniques laser ablation-ICP-MS, glow discharge-MS and spark-OES for the determination of platinum group metals in Pb buttons obtained by fire assay of platiniferous ores

M. Resano, E. García-Ruiz, K. S. McIntosh, J. Hinrichs, I. Deconinck and F. Vanhaecke, J. Anal. At. Spectrom., 2006, 21, 899 DOI: 10.1039/B603270B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements