Issue 7, 2005

Radial ICP characteristics for ICP-AES using direct injection or microconcentric nebulisation

Abstract

Radial analyte signal intensities, fundamental plasma parameters, and non-spectral interference effects were characterized for inductively coupled plasma atomic emission spectrometry (ICP-AES) using a direct injection nebuliser (Vulkan DIN) or a microconcentric nebuliser (MCN) coupled to a cyclonic spray chamber for sample introduction. Radial analyte signal intensity profiles for atomic and ionic lines with energy sum (Esum) between 1.85 and 15.41 eV were used. When using the MCN system, for all lines the signal intensity profiles were parabolic with maxima at the axial centre of the plasma. For the Vulkan DIN, the shapes of the profiles were dependent on their Esum showing minimum intensities at the axial centre of the plasma for lines with high Esum values. The ionisation temperature, electron number density and magnesium ion-atom line intensity ratio determined indicated that ionisation and excitation capabilities were deteriorated at the centre of the plasma when using the Vulkan DIN compared with the MCN. This was found to be not simply a result of high aerosol load when using the Vulkan DIN, but because of poor plasma–aerosol interaction, possibly caused by the confined distribution of aerosol in the plasma and high nebuliser gas velocity. Indeed, for the Vulkan DIN, electron number density and ionisation temperature increased with liquid flow rate, which could be explained by plasma shrinkage, or the thermal pinch effect, which increased the aerosol–plasma interaction at increased liquid flow rates. As a consequence, when increasing the liquid flow rate in the range 20–90 μL min−1: (i) analyte sensitivity increased linearly; (ii) the plasma became unstable; (iii) the magnitude of matrix effects remained almost unaffected. These results are partly in contrast to observations made with other types of direct injection nebulisers and ICP instruments.

Graphical abstract: Radial ICP characteristics for ICP-AES using direct injection or microconcentric nebulisation

Article information

Article type
Paper
Submitted
28 Oct 2004
Accepted
04 May 2005
First published
25 May 2005

J. Anal. At. Spectrom., 2005,20, 645-651

Radial ICP characteristics for ICP-AES using direct injection or microconcentric nebulisation

D. Goitom, E. Björn, W. Frech and M. T. C. de Loos-Vollebregt, J. Anal. At. Spectrom., 2005, 20, 645 DOI: 10.1039/B416594B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements