Emilio
Palomares
*,
Ramón
Vilar
and
James R.
Durrant
Department of Chemistry, Imperial College London, South Kensington, London, UK SW7 2AY. E-mail: e.palomares@imperial.ac.uk; Fax: +44 20 7594 5801; Tel: +44 20 7594 5321
First published on 19th January 2004
A novel chemical sensor for the colorimetric detection of mercuric salts is described. The sensor is based on a mesoporous nanocrystalline TiO2 film sensitised with a ruthenium dye; immersion of this film in an aqueous solution of Hg2+ results in a rapid colorimetric response, with both a high selectivity and a sub-micromolar sensitivity.
Mesoporous nanocrystalline TiO2 films are potentially interesting materials for the development of optical sensors due to their high surface area and excellent optical transparency in the visible region of the spectrum (λ > 400 nm). The adsorption of molecular dyes to the surface of these films has led to applications such as electrochromic windows,8 solar cells,9 biosensors,10 heterosupramolecular devices11 and, as we have recently reported, the heterogeneous sensing of anions down to micromolar concentrations.12 Herein, we report the realization of a colorimetric and spectrophotometric chemical sensor based on a dye sensitised mesoporous TiO2 film capable of detecting sub-micromolar concentrations of toxic mercuric salts.
In particular, we have investigated the ability of the TiO2 /N719 [N719 = bis(2,2′-bipyridyl-4,4′-dicarboxylato)ruthenium(II) bis-tetrabutylammonium bis-thiocyanate] films to act as a colorimetric and spectrophotometric sensor for the detection of metal cations in aqueous solutions (Scheme 1). To do so, the ruthenium complex (N719) was adsorbed onto a 4 µm thick TiO2 film by soaking the film in 1 mM solution of the dye in a 1∶1 mixture of acetonitrile/tert-butanol at room temperature overnight. The cation sensing experiments with the TiO2/N719 films were carried out in distilled water (pH ∼ 5)13 by exposing the films to micromolar solutions of the metal cations under study (i.e. Ca2+, Mg2+, Mn2+, Fe2+ and all of the metal cations catalogued by the Environmental Protection Agency14 as “drinking water contaminants”, namely Cd2+, Co2+, Cu2+, Hg2+, Ni2+, Pb2+ and Zn2+). Remarkably, as illustrated in Fig. 1, the TiO2/N719 film demonstrated a change in its colour only in the presence of Hg2+. Fig. 2 shows the corresponding spectral shift, with Hg2+ immersion resulting in a hypsochromic shift of the N719 visible absorption band from 535 to 481 nm. No optical changes of the films were observed with any other of the metals under study even when the films were exposed to millimolar concentrations.15 The kinetics of the color change in the presence of Hg2+ were observed to be dependent upon the concentration of Hg2+ (see insert Fig. 2), ranging from seconds at millimolar concentrations to minutes at low concentrations. This colour change was found to be irreversible, persisting for several weeks and being insensitive to subsequent drying of the film and rinsing in Hg2+ free control solutions.
![]() | ||
Scheme 1 |
![]() | ||
Fig. 1 Color changes observed after the TiO2/N719 film was dipped for 10 min in a 20 µM aqueous solutions of the indicated metals. |
![]() | ||
Fig. 2 Normalized absoption spectra of a TiO2/N719 before (A) and after (B) the film was immersed for 10 min in a 4 mL quartz cuvette containing a 20 µM solution of Hg2+. The inset shows the kinetics of the change in absorption measured at λ = 480 nm following immersion of the TiO2/N719 film in aqueous solutions with (a) 0 M, (b) 10−5 M and (c) 10−4M Hg2+. |
The color change in the presence of Hg2+ was found to be insensitive to interference by other metal cations. A TiO2/N719 film was exposed to a solution containing sub-micromolar amounts of Hg2+ and micromolar quantities of all the other metal cations under study. The optical changes of the film were identical to those observed for solutions containing only mercury, demonstrating the lack of interference by other cations. Similarly, the effect of anionic species was studied by adding to the Hg2+ solution micromolar amounts of F−, Cl−, Br−, I−, AcO−, NO3− and HSO4− (as their tetrabutylammonium salts). No interference in the presence of these anionic species was observed.
The sensitivity of the TiO2/N719 film for the detection of Hg2+ cations was investigated by “naked eye” and spectrophotometric studies as a function of Hg2+ concentration. “Naked eye” detection was found to be possible down to 20 µM of Hg2+. Spectrophotometric detection allowed the sensing down to ∼0.3 µM of Hg2+ (0.5 ppm of Hg2+), as illustrated in Fig. 3.
![]() | ||
Fig. 3 Titration of the change in the absorption of a N719/TiO2 film measured at 550 nm vs. the concentration of added Hg2+ ions. Measurements were carried out 1 min after each addition of Hg2+ ions. |
The origin of the sub-micromolar sensitivity of this sensing system to Hg2+ requires careful consideration. The TiO2/N719 films employed in this study have an area of 1 cm2 and bind approximately 300 nmol of ruthenium dye (determined from the film optical density, and employing a N719 extinction coefficient of 12000 M−1 cm−1 at 535 nm). We observe that complete color change of the film from red–purple (λmax
= 535 nm) to yellow (λmax
= 481 nm) occurs at levels of mercury as low as 60 nmol (20 µM in 3 cm3), corresponding to an Hg2+ to N719 dye ratio of approximately 1 to 5. This observation suggests that the process responsible for the colour change of the N719 dye involves a chemical transformation catalysed by the Hg2+ ions rather than the formation of a 1∶1 complex. The kinetic data shown in Fig. 2 are consistent with a catalytic mode of action, with the rate of colour change increasing as the Hg2+ concentration is increased. However we note that the saturation in the colour change observed for all Hg2+ concentrations at long times implies that the reaction is only partially catalytic, with the Hg2+ being rapidly consumed in the reaction.
We assign the hypsochromic shift of the N719 absorption band observed in the presence of Hg2+ ions to a transformation of the NCS ligands of this dye. Previous studies have reported a blue shift of the N719 absorption in the presence of chemical oxidants (such as H2O2) or after long period irradiation of the film; under these conditions this blue shift has been assigned to loss of sulfur from the NCS ligand leading to formation of coordinated cyanide. Our assignment of the hypsochromic shift observed here to transformation of the NCS ligands was further supported by FTIR and Raman spectra, which both showed that immersion of the film in Hg2+ solutions resulted in a disappearance of the 2105 cm−1 band assigned previously to the CN vibration of the NCS ligand.
It has been previously reported that Hg2+ can be used in the catalytic desulfurisation of organic moieties,4 consistent with the results we report here. We note however that the nature of the ruthenium complex resulting from the catalytic reaction here proposed remains unclear. IR and Raman spectra of the Hg2+ treated TiO2/N719 films showed the appearance of a new band at ∼2140 cm−1, distinct from the νCN band (at 2080 cm−1) reported previously for ruthenium cyanide complexes. Experiments are underway to understand the details of this interesting chemical process.
In conclusion, we have demonstrated a novel and practical heterogenous system for the colorimetric sensing of Hg2+ in aqueous solutions at room temperature. The system exhibits a sub-micromolar sensitivity, attributed to a transformation of the thiocyanate ligands of the sensor dye induced by Hg2+ ions. The sensor is found to be highly selective, being insensitive to all other metal ions of concern as drinking water pollutants.
The authors are grateful to the EPSRC and to the EU (Marie Curie Fellowship Contract No. HPMF-CT-2002-01744 for E. P.) for their financial support.
Footnote |
† Electronic supplementary information (ESI) available: Materials and methods. See http://www.rsc.org/suppdata/cc/b3/b314138a/ |
This journal is © The Royal Society of Chemistry 2004 |