Issue 9, 2001

Abstract

Electrothermal vaporization (ETV) ICP mass spectrometry is a method that combines the ability of the graphite furnace to handle complex samples with the detection power of ICP-MS. It is somewhat surprising, however, that most works reporting on the application of this method have only described the “simultaneous” (from the same tube firing) determination of 1–3 elements. Different authors have attributed this fact to the limited capability of the quadrupole filter (the most commonly used mass spectrometer in ICP-MS instrumentation) to deal with the transient signals that electrothermal vaporization produces. Nevertheless, recent works suggest that the real multi-element capabilities of ETV quadrupole-based ICP-MS might have been largely underestimated. A systematic study of the number of mass-to-charge ratios that can be “simultaneously” monitored in ETV quadrupole-based ICP-MS without degrading the precision, the sensitivity and the limits of detection has been carried out. Three elements with different furnace behaviours (Cd, Co and Ti) were chosen for the study. The effect of the dwell time and the way of processing the analytical data were also evaluated. The results indicate that, when using ETV-ICP-MS with a quadrupole-based instrument, no detrimental effects on the precision, detection limits and sensitivity occur as long as a critical value of three or four points to define the signal profile is achieved. This requirement corresponds to the possibility of monitoring more than 20 elements for a standard peak width of 1.5–2 s. Several options for further improvements are also discussed, including the possibility of separating (with respect to time) the vaporization of elements with different furnace behaviours.

Article information

Article type
Paper
Submitted
19 Feb 2001
Accepted
09 May 2001
First published
19 Jun 2001

J. Anal. At. Spectrom., 2001,16, 1018-1027

Evaluation of the multi-element capabilities of electrothermal vaporization quadrupole-based ICP mass spectrometry

M. Resano, M. Verstraete, F. Vanhaecke and L. Moens, J. Anal. At. Spectrom., 2001, 16, 1018 DOI: 10.1039/B101588P

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements