Issue 5, 2000

Abstract

A method has been developed for the atmospheric sampling and analysis of four perfluorocarbon tracer (PFT) compounds simultaneously at the parts per trillion (ppt) level. PFTs were pre-concentrated using adsorbent tube air sampling. Analysis was achieved by thermal desorption (TD) and gas chromatography (GC) with electron capture detection (ECD). Efficient separation of the PFTs from the other sample constituents was achieved by use of a capillary porous layer open tubular (PLOT) GC column without the need to cool the GC oven to sub-ambient temperatures using liquid coolants (M. de Bortoli and E. Pecchio, J. High Resolut. Chromatogr., 1985, 8, 422) or for a catalytic destruction step to remove interferents (T. W. D'Ottavio, R. W. Goodrich and R. N. Dietz, Environ. Sci. Technol., 1986, 20, 100). Results from test field trials with two volatile PFTs that were buried to simulate an underground leaking cable were successful. The PFTs were detected above ground level to pinpoint the leak position. The highest tracer concentrations were detected within 1 m of the simulated leak positions 2 days after tracer burial. The developed technology was applied to an oil leaking high voltage electricity cable. One PFT was added to the cable oil which enabled detection of the oil leak to within 3 m. The reported method has many advantages over currently used leak detection methods and could, in the future, be applied to the detection of underground leaks in a variety of cables and pipes.

Article information

Article type
Paper
Submitted
28 Jun 2000
Accepted
18 Aug 2000
First published
11 Sep 2000

J. Environ. Monit., 2000,2, 432-435

Development of perfluorocarbon tracer technology for underground leak location

S. Hassoun, T. McBride and D. A. Russell, J. Environ. Monit., 2000, 2, 432 DOI: 10.1039/B005190J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.