Quantitation of perchlorate ion by electrospray ionization mass spectrometry (ESI-MS) using stable association complexes with organic cations and bases to enhance selectivity

(Note: The full text of this document is currently only available in the PDF Version )

Edward T. Urbansky, Matthew L. Magnuson, David Freeman and Christopher Jelks


Abstract

Quantitation of trace levels of perchlorate ion in water has become a key issue since this species was discovered in water supplies around the United States. Although ion chromatographic methods presently offer the lowest limit of detection, ≈40 nM (4 ng ml–1), chromatographic retention times are not considered to be unique identifiers and often cannot be used in legal proceedings without confirmatory testing. Mass spectrometry can provide such confirmation; however, detection capabilities can impose a practical limitation on its use. Moreover, quadrupole mass spectrometers cannot provide sufficient accuracy and precision in m/z to identify conclusively an ion as perchlorate when samples are run directly without prior chromatographic or electrophoretic separation. We report on the abilities of (1) tetralkylammonium cations and (2) minimally nucleophilic, sterically hindered organic bases to increase selectivity in the electrospray ionization mass spectrometric (ESI-MS) determination of perchlorate ion without concomitant loss of sensitivity. Selectivity arises from the formation of a stable association complex between a base molecule and a perchlorate anion. The best results were obtained using 10 µM chlorhexidine in methanolic solution; the lower limit of detection (LLOD) for S/N ≥ 2 was less than or equal to 0.10 µM (10 ng ml–1). This compares favorably with the LLOD determined for perchlorate in the absence of any complexing agents (≈0.05 µM = 5 ng ml–1). For the other bases, which were diazabicyclo compounds (DBN, DBU, DBO), sensitivity was lower by 90% or more. The chlorhexidine–perchlorate complex (m/z = 605) can be observed even in the presence of equiformal nitrate, nitrite, hydrogensulfate, chloride, bromide, bromate, and chlorate (all together) down to approximately 1 µM; thus, the method is rugged enough to find application to systems containing multiple inorganic anions.


References

  1. E. T. Urbansky, Biorem. J., 1998, 2, 18 Search PubMed and references cited therein.
  2. E. T. Urbansky and M. R. Schock, J. Environ. Manag., 1999, 56, 79 Search PubMed.
  3. US Environmental Protection Agency, Perchlorate Environmental Contamination: Toxicological Review and Risk Characterization Based on Emerging Information, Review Draft, December 31, 1998, Document No. NCEA-1-503 Search PubMed.
  4. P. C. Hauser, N. D. Renner and A. P. C. Hong, Anal. Chim. Acta, 1994, 295, 181 CrossRef CAS.
  5. D. A. Barnett and G. Horlick, J. Anal. At. Spectrom., 1997, 12, 497 RSC.
  6. A. A. Ensafi and B. Rezaei, Anal. Lett., 1998, 31, 167 CAS.
  7. B. Gu, G. M. Brown, S. D. Alexandratos, R. Ober and V. Patel, Selective Anion Exchange Resins for the Removal of Perchlorate ClO4 from Groundwater, Oak Ridge National Laboratory, Oak Ridge, TN, February, 1999, Doc. No. ORNL/TM-13753, Environmental Sciences Division Publication No. 4863 Search PubMed.
Click here to see how this site uses Cookies. View our privacy policy here.