Three approaches to the development of selective bilayer amperometric biosensors for glucose by in situ electropolymerization

(Note: The full text of this document is currently only available in the PDF Version )

Juan-Carlos Vidal, Esperanza García, Silvia Méndez, Pilar Yarnoz and Juan-Ramón Castillo


Abstract

Three different glucose oxidase biosensors for the enzymatic determination of glucose, based on bilayer polymer coatings consisting of polypyrrole (PPy) and poly(o-phenylenediamine), were developed. The electrode substrates are Pt metal, carbon paste and an organic conducting salt (tetrathiafulvalene–tetracyanoquinodimethane), which introduces appreciable variability in the electrode construction process. The three sensors were compared with one another and with bare and PPy monolayer-coated sensors in terms of performance in the determination of glucose in a synthetic serum sample. These configurations provide improved selectivity against the interferences of electroactive species such as ascorbic acid and uric acid, frequently present in biological samples, and the differences between them can be taken advantage of in application to different kinds of samples.


References

  1. P. Pantano and W. G. Kuhr, Electroanalysis, 1995, 7, 405 CAS.
  2. S. A. Wring and J. P. Hart, Analyst, 1992, 117, 1215 RSC.
  3. P. Vadgama and P. W. Crump, Analyst, 1992, 117, 1657 RSC.
  4. R. Wilson and A. P. F. Turner, Biosens. Bioelectron., 1992, 7, 165 CrossRef CAS.
  5. P. N. Bartlett and P. R. Birkin, Synth. Met., 1993, 61, 15 CAS.
  6. M. Trojanowicz and T. Krawczynski vel Krawczyk, Mikrochim. Acta, 1995, 121, 167 CAS.
  7. W. Schuhmann, Mikrochim. Acta, 1995, 121, 1 CAS.
  8. F. Palmisano, A. Guerrieri, M. Quinto and P. G. Zambonin, Anal. Chem., 1995, 67, 1005 CrossRef CAS.
  9. I. Losito and C. G. Zambonin, J. Electroanal. Chem., 1996, 410, 181 CrossRef CAS.
  10. C. G. Zambonin and I. Losito, Anal. Chem., 1997, 69, 4113 CrossRef CAS.
  11. F. Palmisano, D. Centonze, M. Quinto and P. G. Zambonin, Biosens. Bioelectron., 1996, 11, 419 CrossRef CAS.
  12. J. C. Vidal, E. García and J. R. Castillo, Biosens. Bioelectron., 1998, 13, 371 CrossRef CAS.
  13. K. McAteer and R. D. O'Neill, Analyst, 1996, 121, 773 RSC.
  14. A. M. Farrington and J. M. Slater, Electroanalysis, 1997, 9, 843 CAS.
  15. L. Spurlock, A. Jaramillo, A. Praserthdam, J. Lewis and A. Brajter-Toth, Anal. Chim. Acta, 1996, 336, 37 CrossRef.
  16. J. Wang, L. Chen and D. B. Luo, Anal. Commun., 1997, 34, 217 RSC.
  17. M. Lobo, A. Miranda, J. Lopez and P. Tuñon, Anal. Chim. Acta, 1996, 325, 33 CrossRef CAS.
  18. F. Palmisano, D. Centonze, C. Malitesta and P. G. Zambonin, J. Electroanal. Chem., 1995, 381, 235 CrossRef CAS.
  19. D. Centonze, I. Losito, C. Malitesta, F. Palmisano and P. G. Zambonin, J. Electroanal. Chem., 1997, 435, 103 CrossRef CAS.
  20. S. Zhao, U. Korell, L. Cuccia and B. Lennox, J. Phys. Chem., 1992, 96, 5641 CrossRef CAS.
  21. M. Hämmerle, W. Schuhmann and H. L. Schmidt, Sens. Actuators B, 1992, 6, 106 CrossRef.
  22. Z. Zhang, H. Liu and J. Deng, Anal. Chem., 1996, 68, 1632 CrossRef CAS.
  23. D. Centonze, C. Malitesta, F. Palmisano and P. G. Zambonin, Electroanalysis, 1994, 6, 423.
  24. D. Centonze, A. Guerrieri, C. Malitesta, F. Palmisano and P. G. Zambonin, Fresenius' J. Anal. Chem., 1992, 342, 729 CrossRef CAS.
Click here to see how this site uses Cookies. View our privacy policy here.