Determination of hexamethylene-based isocyanates in spray-painting operationsPart 1. Evaluation of a polyurethane foam sponge sampler

(Note: The full text of this document is currently only available in the PDF Version )

Walter E. Rudzinski, Jian Yin, Samuel H. Norman and Deborah A. Glaska


Abstract

A polyurethane foam (PUF) sponge was mounted in a cassette sampler and evaluated as a sorbent for the collection of hexamethylene diisocyanate (HDI) monomer and HDI-based oligomers. Recovery studies indicated 112 ± 34% average recovery of HDI monomer and 92 ± 9% and 97 ± 25% average recovery of HDI-based oligomers when using impregnated PUF sponges. The PUF sponge was also evaluated during actual spray-painting operations. In a series of side-by-side sampling events, an impinger filled with 1-(2-methoxyphenyl)piperazine (MOP) in toluene was compared directly with a cassette sampler containing a PUF sponge impregnated with MOP or 1-(9-anthracenylmethyl)piperazine (MAP) in dimethyl sulfoxide (DMSO). For the analysis of HDI-based oligomer, there is no significant difference (p < 0.05, n = 7) in the air concentration when sampling with either the PUF sponge cassette or the impinger. The results are significant because they indicate that a PUF sponge, which is more convenient than an impinger, may be used for the collection of HDI-based oligomer generated during spray-painting operations.


References

  1. S. Silk and H. Hardy, Ann. Occup. Hyg., 1996, 27, 333.
  2. L. Belin, U. Hjortsberg and U. Wass, Scand. J. Work Environ. Health, 1981, 7, 310 Search PubMed.
  3. J. L. Malo, G. Ouimet, A. Cartier, D. Levitz and R. Zeiss, J. Allergy Clin. Immunol., 1983, 72, 413 CrossRef CAS.
  4. J. Nielsen, C. Sango, G. Winroth, T. Hallberg and S. Skerfving, Scand. J. Work Environ. Health, 1985, 11, 51 Search PubMed.
  5. O. Vandenplas, A. Cartier, J. LeSage, Y. Cloutier, G. Perreault, L. C. Grammer, M. A. Shaughnessy and J.-L. Malo, J. Allergy Clin. Immunol., 1993, 91, 850 CAS.
  6. G. Tornling, R. Alexandersson, G. Hedenstierna and N. Plato, Am. J. Ind. Med., 1990, 17, 299.
  7. M. Janko, K. McCarthy, M. Fajer and J. van Raalte, Am. Ind. Hyg. Assoc. J., 1992, 53, 331–338 CrossRef CAS.
  8. C. J. Purnell and R. Walker, Analyst, 1985, 110, 893 RSC.
  9. V. Dharmarajan, R. D. Lingg, K. S. Booth and D. R. Hackathorn, in Sampling and Calibration for Atmospheric Measurements, ASTM Special Technical Publication No. 957, ed. J. K. Taylor, American Society for Testing and Materials, Philadelphia, PA, 1988, pp. 190–202 Search PubMed.
  10. S. P. Levine, K. J. D. Hillig, V. Dharmarajan, M. W. Spence and M. D. Baker, Am. Ind. Hyg. Assoc. J., 1995, 56, 581–589 CrossRef CAS.
  11. Method 42: Diisocyanates, in OSHA Methods Manual, Occupational Safety and Health Administration, Salt Lake City, UT, USA, 1994, pp. 42-1–42-39 Search PubMed.
  12. Method No. 5521: Isocyanates, Monomeric, Issue 2, in NIOSH Manual of Analytical Methods, DHHS(NIOSH) Publication No. 94-113, Vol. 2, ed. P. M. Eller, National Institute for Occupational Safety and Health, Cincinnati, OH, 4th edn., 1994 Search PubMed.
  13. MDHS 25: Organic Isocyanates in Air, in Methods for the Determination of Hazardous Substances, Health and Safety Executive, Occupational Safety and Hygiene Laboratory, London, 1987 Search PubMed.
  14. P. M. Hext, A Comparison of the Sampling Efficiencies of a Range of Atmospheric Samplers When Collecting Polymeric MDI Aerosols, International Isocyanate Institute, 1996, Reference 11232 Search PubMed.
  15. S. P. Levine, K. J. D. Hillig, V. Dharmarajan, M. W. Spence and M. D. Baker, Am. Ind. Hyg. Assoc. J., 1995, 56, 581 CrossRef CAS.
  16. R. P. Streicher, J. E. Arnold, M. K. Ernst and C. V. Cooper, Am. Ind. Hyg. Assoc. J., 1996, 57, 905 CrossRef CAS.
  17. Desmodur N-100 Material Safety Data Sheet, Bayer, Pittsburgh, PA, 1996 Search PubMed.
Click here to see how this site uses Cookies. View our privacy policy here.