Comparison of various adsorbents for long-term diffusive sampling of volatile organic compounds

(Note: The full text of this document is currently only available in the PDF Version )

Naciye Kilic and James A. Ballantine


Abstract

The relative performances of diffusive samplers packed with Tenax TA, Chromosorb 106 and Carbotrap for the long-term diffusive sampling of several typical volatile organic compounds were compared. In order to measure the magnitudes of the decreases in mass uptakes in a real long-term diffusive sampling situation, the results for 7 and 14 d sampling periods were compared with the sum of consecutive 1 d diffusive sampling results, performed in parallel for the same period of time. The results of this study gives information about the magnitudes of the decreases in mass uptakes in a real sampling situation and show the limitations of the adsorbents tested for the sampling of volatile organic compounds from different classes such as acetone and dichloromethane as compounds with a functional group, toluene as an example of aromatic compounds and pentane, hexane, nonane, decane and undecane as examples of straight chain hydrocarbons (C5–C11). It was shown that the data obtained from long-term diffusive sampling are subject to significant error, particularly for low boiling compounds. Chromosorb 106 could be the adsorbent of choice for this sampling situation, as it gives the highest percentage of masses (ng) collected for longer exposure periods relative to the sum of the masses (ng) collected over each exposure period among the other adsorbents tested.


References

  1. Mixed Hydrocarbons (C5 to C10) in Air, MDHS 66, Health and Safety Executive, Occupational Medicine and Hygiene Laboratory, London, 1989 Search PubMed.
  2. Benzene in Air, MDHS 50, Health and Safety Executive, Occupational Medicine and Hygiene Laboratory, London, 1985 Search PubMed.
  3. M. D. Wright, BCR Certification of Reference Materials—Organicson Tenax—A Critical Examination of Sources of Error, Health and Safety Executive, Occupational Medicine and Hygiene Laboratory, Report IR/L/IA/93/3, London, 1993 Search PubMed.
  4. R. H. Brown and K. J. Walkin, Anal. Proc., 1981, 18, 205 Search PubMed.
  5. D. R. Crump and I. M. Madany, Proc. Indoor Air, 1993, 2, 15 Search PubMed.
  6. V. M. Brown, D. R. Crump and D. Gardiner, Environ. Technol., 1992, 13, 367 Search PubMed.
  7. V. M. Brown and D. R. Crump, in Proceedings of the International Conference on Volatile Organic Compounds in the Environment, ed. Leslie, G., and Perry, R., IAI, Rothenfluh, 1993, pp. 241–249 Search PubMed.
  8. N. van den Hoed and M. T. H. Halmans, J. Am. Ind. Hyg. Assoc., 1987, 48, 364 Search PubMed.