Wearable microdialysis system for continuous in vivo monitoring of glucose

(Note: The full text of this document is currently only available in the PDF Version )

T. Vering, S. Adam, H. Drewer, C. Dumschat, R. Steinkuhl, M. Knoll, A. Schulze and E. G. Siegel


Abstract

We developed a new system to monitor glucose continuously in vivo. The miniaturised system is very easy to handle and was optimised to a resource-saving working modus. Sampling was performed by means of a biocompatible microdialysis needle probe inserted into the subcutaneous tissue. During glucose tolerance tests the results of our monitoring system were correlated with the glucose level of the venous blood stream. A comparison according to the procedure known as ‘error grid analysis’ provided an excellent correlation between the two completely independent analyses systems with the reference determination results. All values obtained with our systems were clinically correct or at least clinically acceptable.


References

  1. T. Laurell, J. Med. Eng. Techn., 1992, 16, 187 Search PubMed.
  2. A. J. M. Schoonen, F. J. Schmidt, H. Hasper, D. A. Verbrugge, R. G. Tiessen and C. F. Lerk, Biosens. Bioelectron., 1990, 5, 37 CrossRef CAS.
  3. A. L. Aalders, F. J. Schmidt, A. J. M. Schoonen, I. R. Broek, A. G. F. M. Maessen and H. Doorenbos, Intern. J. Artif. Organ., 1991, 14, 102 Search PubMed.
  4. E. Dempsey, D. Diamond, M. R. Smyth, M. A. Malone, K. Rabenstein, A. McShane, M. McKenna, T. V. Keaveney and R. Freaney, Analyst, 1997, 122, 185 RSC.
  5. H. Langemann, A. Mendelowitsch, H. Landolt, B. Alessandri and O. Gratzl, Clin. Neurolog. Neurosurg., 1995, 97, 149 Search PubMed.
  6. U. Ungerstedt, J. Internal Med., 1991, 230, 365 Search PubMed.
  7. C. Meyerhoff, F. Bischof, F. Sternberg, H. Zier and E. F. Pfeiffer, Diabetologia, 1992, 35, 1087 CAS.
  8. W. Kerner, M. Kiwit, K. Thomas, B. Linke and L. Hua, Diabetes, 1995, 44, 69A Search PubMed.
  9. R. Steinkuhl, H. Hinkers, C. Dumschat, M. Knoll and K. Cammann, Horm. Metab. Res., 1994, 26, 531 CAS.
  10. M. Knoll, German Patent No. DE 4115414A1, 1991.
  11. N. Conrath, N. Czupor, R. Steinkuhl, C. Sundermeier, D. Trau, M. Wittkampf, H. Hinkers, M. Meusel, G. Chemnitius, M. Knoll, F. Spener and K. Cammann, Transducers '97, International Conference on Solid-State Sensors and Actuators, Digest of Technical Papers, Chicago, June 16–19 1997, 1997, p. 481 Search PubMed.
  12. R. Steinkuhl, C. Sundermeier, H. Hinkers, C. Dumschat, K. Cammann and M. Knoll, Sens. Actuators, 1996, B33, 19 Search PubMed.
  13. U. Fischer, Acta Anaesthesiol. Scand. Suppl., 1995, 104, 21 Search PubMed.
  14. T. Kondo, K. Ito, K. Ohkura, K. Ito and S. Ikeda, Diabetes Care, 1982, 5, 218 Search PubMed.
  15. E. Ohashi and I. Karube, J. Biotechnol., 1995, 40, 13 CrossRef CAS.
  16. T. Von Woedtke, W. Juelich, P. Abel, U. Fischer and A. Kramer, Biomed. Techn. Suppl., 1994, 39, 109 Search PubMed.
  17. F. Spener, R. Steinkuhl, C. Dumschat, H. Hinkers, K. Cammann and M. Knoll, Carbohydr. Bioeng., 1995, 49 Search PubMed.
  18. R. Steinkuhl, C. Dumschat, C. Sundermeier, H. Hinkers, R. Renneberg, K. Cammann and M. Knoll, Biosens. Bioelectron., 1996, 11, 187 CrossRef CAS.
  19. P. Arner and J. Bolinder, J. Internal Med., 1991, 230, 381 Search PubMed.
  20. E. F. Pfeiffer, Horm. Metab. Res., 1994, 26, 510 CAS.
  21. D. Moscone and M. Mascini, Ann. Biol. Clin. (Paris), 1992, 50, 323 Search PubMed.
  22. W. L. Clark, D. Cox, L. A. Gonder-Frederick, W. Carter and S. L. Pohl, Diabetes Care, 1987, 10, 622 Search PubMed.
  23. G. Jobst, I. Moser, M. Varahram, P. Svasek, E. Aschauer, Z. Trajanoski, P. Wach, P. Kotanko, F. Skrabal and G. Urban, Anal. Chem., 1996, 68, 3173 CrossRef CAS.
  24. U. Fischer, K. Rebrin, T. v. Woedtke and P. Abel, Horm. Metab. Res., 1994, 26, 515 CAS.
Click here to see how this site uses Cookies. View our privacy policy here.