Aryl vinyl sulfides as probes for electrophilic versus electron transfer mechanisms

(Note: The full text of this document is currently only available in the PDF Version )

J. Todd Aplin and Nathan L. Bauld


Abstract

The distinction between electrophilic and electron transfer mechanisms of addition reactions to the vinyl double bond of aryl vinyl sulfides, ethers and selenides has been achieved by studying substituent effects. Specifically, the effects of meta and para substituents on the rates of electrophilic addition reactions correlate with Hammett σ values, while ionization of the substrates to the corresponding radical cations correlates with σb+. The significance of the respective correlations are confirmed by statistical tests. The σ (electrophilic)/σb+ (ET) dichotomy is in accord with the conventional paradigm for σ/σb+ correlations and is further supported by ab initio SCF MO calculations. The application of this criterion to the reactions of aryl vinyl sulfides and ethers with tetracyanoethylene indicates that formation of cyclobutanes occur via direct electrophilic addition to the electron-rich alkene and not via an electron transfer mechanism. This conclusion is further supported by the results of previous radical cation probe studies.


References

  1. M. Hojo, R. Masuda, Y. Kamitori and E. Okada, J. Am. Chem. Soc., 1991, 56, 1975 CAS.
  2. (a) R. A. McClelland, Can. J. Chem., 1977, 55, 548 CAS; (b) T. Fueno, I. Matsumura, T. Okuyama and J. Furukawa, Bull. Chem. Soc. Jpn., 1968, 41, 818 CAS; (c) R. A. McClelland and M. Leung, J. Org. Chem., 1980, 45, 187 CrossRef CAS.
  3. T. Lowry and K. S. Richardson, Mechanism and Theory in Organic Chemistry, Harper and Row, New York, 1987, p. 150 Search PubMed.
  4. Ab initio molecular orbital calculations were carried out on a Cray YMP computer using Gaussian 92 software. Structures were fully optimized at the 6-31G* level.
  5. Electrochemical measurements were performed using a Bioanalytical Systems 100 electrochemical analyser in the DPV mode scanning from 700 to 1500 mV at a scan rate of 4 mV s–1 with a pulse amplitude of 50 mV, a pulse width of 50 ms, a pulse period of 1000 ms and a sensitivity of 1 × 10–6. The DPV measurements were carried out using a divided cell equipped with a platinum disk working electrode (anode), a reticulated vitreous carbon counter electrode and a Ag/Ag+ reference electrode (calibrated against ferrocene/ferrocene+) in 0.1 m LiClO4 in acetonitrile. The analyte concentration was 0.5–1.0 mg ml–1.
  6. D. P. Shoemaker, C. W. Garland and J. W. Nibbler, Experiments in Physical Chemistry, McGraw Hill, New York, 1989, 811 Search PubMed.
  7. For a description of the methods used in the competition kinetics, see W. Yueh and N. L. Bauld, J. Am. Chem. Soc., 1995, 117, 5671 Search PubMed.
  8. B. N. Solomonov, I. A. Arkhirieva and A. I. Konovalov, Zh. Org. Khim., 1980, 16, 1666; 1670.
  9. T. Kim, H. Sarker and N. L. Bauld, J. Chem. Soc., Perkin Trans 2, 1995, 577 RSC.
Click here to see how this site uses Cookies. View our privacy policy here.