Abstract

The construction of a wall-jet flow cell, which houses a screen-printed amperometric pesticide biosensor, together with a complete flow-injection system, is described. This system was initially employed in studies to stabilise the enzyme acetylcholinesterase (AChE), which was immobilised on a cobalt phthalocyanine screen-printed carbon electrode to form a biosensor. A combination of dextran sulfate and lactitol, and carbodiimide for enzyme immobilisation, resulted in biosensor lifetimes of at least 76 d (at 37 °C). Flow-injection and biosensor conditions were optimised, then the system was evaluated by monitoring the model organophosphate pesticides (OP) dichlorvos and paraoxon. The detection limits were 7 × 1011 mol dm3 (for 1 U of AChE) and 4 × 1011 mol dm3 (for 0.05 U of AChE), respectively, which are better than for other electrochemical methods. Initial evaluations on two river water samples have been carried out to test the validity of the system for OP determination in field samples.


References

  1. G. D. D'Mello, Hum. Exp. Toxicol., 1993, 12, 3 Search PubMed.
  2. C. Shepherd, Practitioner, 1993, 237, 212 Search PubMed.
  3. F. M. Corrigan, S. MacDonald, A. Brown, K. Armstrong and E. M. Armstrong, Med. Hypotheses, 1994, 43(4), 195 CrossRef CAS.
  4. A. Di Corcia and M. Marchetti, Anal. Chem., 1991, 63, 580 CrossRef CAS.
  5. C. Tran-Minh, P. C. Pandey and S. Kumaran, Biosens. Bioelectron., 1990, 5, 461 CrossRef CAS.
  6. C. Ristori, C. Del Carlo, M. Martini, A. Barbaro and A. Ancarani, Anal. Chim. Acta, 1996, 325, 151 CrossRef CAS.
  7. M. Bernabei, S. Chiavarini, C. Cremisini and G. Palleschi, Biosens. Bioelectron., 1993, 8, 265 CrossRef CAS.
  8. C. La Rosa, F. Pariente, L. Hernandez and E. Lorenzo, Anal. Chim. Acta, 1995, 308, 129 CrossRef CAS.
  9. M. Stoytchera, Electroanalysis, 1995, 7(7), 660.
  10. P. Skaldal, Anal. Chim. Acta, 1991, 7(5), 335.
  11. P. Skaldal and M. Mascini, Biosens. Bioelectron., 1992, 7(5), 335 CrossRef CAS.
  12. M. Trojanowitz and M. L. Hitchman, Trends Anal. Chem., 1996, 15(1), 38 CAS.
  13. J. P. Hart and I. C. Hartley, Analyst, 1994, 119, 259 RSC.
  14. I. C. Hartley and J. P. Hart, Anal. Proc., 1994, 131, 333 RSC.
  15. T. D. Gibson, I. J. Higgins and J. R. Woodward, Analyst, 1992, 117, 1293 RSC.
  16. T. D. Gibson and J. R. Woodward, Enzyme Stabilisation, International Patent PCT/GB89/10346, 1989 Search PubMed.
  17. J. J. Rippeth and T. D. Gibson, Abstr. Pap. Am. Chem. Soc., 1997, 213, No. 2 Part 2, 368-PMSE Search PubMed.
  18. The Pesticides Manual, ed. Tomlin, C., The Royal Society of Chemistry, Cambridge, 10th edn., 1994, p. 314 Search PubMed.