Reagentless Amperometric Determination of Hydrogen Peroxide by Silica Sol–Gel Modified Biosensor

(Note: The full text of this document is currently only available in the PDF Version )

Shi Lin Chut and Juan Li


Abstract

A sensitive amperometric hydrogen peroxide biosensor was developed based on the immobilization of horseradish peroxidase (HRP) enzyme by the sol–gel method on a carbon paste electrode in a ‘sandwich configuration’. The configuration of the biosensor is a carbon paste/sol–gel–ferrocene/HRP/sol–gel. The biosensor has a fast response with a linear calibration range of 3–57 µmol dm3 with a sensitivity of 0.067 µA µmol1 (correlation coefficient 0.996). Based on a signal-to-noise ratio of 3, the detection limit of the biosensor is 0.6 µmol dm3. The lifetime, fabrication reproducibility and measurement reproducibility were evaluated and an interference study was carried out. Recoveries measured by the biosensor in various samples were satisfactory.


References

  1. G. Guibault, Analytical Uses of Immobilized Enzymes, Marcel Dekker, New York, 1984 Search PubMed.
  2. Q. Deng and S. Dong, J. Electroanal. Chem., 1994, 377, 191 CrossRef CAS.
  3. S. B. Adeloju, S. J. Shaw and G. G. Wallace, Anal. Chim. Acta, 1996, 323, 107 CrossRef CAS.
  4. J. Rishpon, S. Gottesfeld, C. Campbell, J. Davey and T. A. Zawodzinski, Jr., Electroanalysis, 1994, 6, 17 CAS.
  5. J. Qian, Y. Liu, H. Liu, T. Yu and J. Deng, J. Electroanal. Chem., 1995, 397, 157 CrossRef CAS.
  6. H. Liu, Y. Liu, J. Qian, T. Yu and J. Deng, Talanta, 1996, 43, 111 CrossRef CAS.
  7. Q. Deng, Y. Guo and S. Dong, Anal. Chim. Acta, 1996, 319, 71 CrossRef CAS.
  8. P. D. Sánchez, A. J. M. Ordieres, A. C. Garcia and P. T. Blanco, Electroanalysis, 1991, 3, 281.
  9. I. C. Popescu, G. Zetterberg and L. Gorton, Biosens. Bioelectron., 1995, 10, 443 CrossRef CAS.
  10. J. Wang and Q. Chen, Anal. Chem., 1994, 66, 1007 CrossRef CAS.
  11. Q. Chi and S. Dong, Anal. Chim. Acta., 1993, 278, 17 CrossRef CAS.
  12. D. Avnir, S. Braun, O. Lev, D. Levy and M. Ottolenghi, in Sol–Gel Optics: Processing and Applications, ed. Klein, L. C., Kluwer, Dordrecht, 1994, pp. 539-582 Search PubMed.
  13. O. Lev, M. Tsionsky, L. Rabinovich, V. Glezer, S. Sampath, I. Pankratov and J. Gun, Anal. Chem., 1995, 67, 22A CrossRef CAS.
  14. D. Avnir, Acc. Chem. Res., 1995, 28, 328 CrossRef CAS.
  15. O. Lev, Analusis, 1992, 20, 543 CAS.
  16. S. Sampath and O. Lev, Electroanalysis, 1996, 8, 1112 CAS.
  17. B. G. Milagres, L. T. Kubota and G. Oliveira Neto, Electroanalysis, 1996, 8, 489 CAS.
  18. P. Audebert, C. Demaille and C. Sanchez, Chem. Mater., 1993, 5, 911 CrossRef CAS.
  19. I. Pankratov and O. Lev, J. Electroanal. Chem., 1995, 393, 35 CrossRef CAS.
  20. J. Wang, P. V. A. Pamidi and D. S. Park, Anal. Chem., 1996, 68, 2705 CrossRef CAS.
  21. J. Li, L. S. Chia, N. K. Goh, S. N. Tan and H. Ge, Sens. Actuators B, in the press Search PubMed.
  22. J. Li, S. N. Tan and H. Ge, Anal. Chim. Acta, 1996, 335, 137 CrossRef CAS.
  23. T. Ruzgas, E. Csöregi, J. Emnéus, L. Gorton and G. Marko-Varga, Anal. Chim. Acta, 1996, 330, 123 CrossRef CAS.
  24. L. L. Hench and J. K. West, Chem. Rev., 1990, 90, 33 CrossRef CAS.
  25. R. S. Brown and J. H. T. Luong, Anal. Chim. Acta, 1995, 310, 419 CrossRef CAS.
  26. S. A. Jaffari and A. P. F. Turner, Physiol. Meas., 1995, 16, 1 CrossRef CAS.
  27. M. J. Eddowes, in Biosensors a Practical Approach, ed. Cass, A. E. G., IRL Press, Oxford, 1990, p. 218 Search PubMed.
  28. H. Zollner, Handbook of Enzyme Inhibitors, VCH, Weinheim, 1990, p. 159 Search PubMed.
Click here to see how this site uses Cookies. View our privacy policy here.