Issue 8, 1996

Determination of (ultra)trace amounts of antimony(III) in water by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry

Abstract

A flow injection on-line sorption preconcentration system has been synchronously coupled to an ETAAS system for the selective determination of (ultra)trace amounts of SbIII in water. The determination was achieved by selective complexation of SbIII with ammonium pyrrolidine dithiocarbamate (APDC) at a wide range of sample acidity (0–1 mol l–1 HCl), sorption of the complex onto the inner walls of a knotted reactor made from (100 cm long × 0.5 mm id) PTFE tubing, quantitative elution with 35 µl of ethanol and subsequent ETAAS detection. In order to minimize dispersion and to reduce the eluent volume required for the quantitative elution, an air flow was used to drive the eluent elution and to deliver all the eluate into an unpreheated polycrystalline graphite tube without a platform. Precise timing was not needed for analyte elution and eluate introduction. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 30 s and a sample loading flow rate of 5.4 ml min–1, an enhancement factor of 30 was obtained in comparison with direct injection of 35 µl aqueous solution, resulting in a sampling frequency of 42 samples h–1. The detection limit (3s) was 0.021 µg l–1 and the precision was 2.9%(RSD) for eleven replicate determinations at 1 µg l–1. The introduction of an efficient wash step before elution with the addition of APDC to the wash medium permitted the use of simple aqueous standards for direct calibration in the analysis of sea-water. The accuracy of the proposed method was demonstrated by analysing synthetic mixtures and spiked sea-water.

Article information

Article type
Paper

Analyst, 1996,121, 1061-1067

Determination of (ultra)trace amounts of antimony(III) in water by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry

X. Yan, W. Van Mol and F. Adams, Analyst, 1996, 121, 1061 DOI: 10.1039/AN9962101061

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements