Abstract

A model is presented that describes aspects of the transient and steady-state behaviour of toxicity monitoring biosensors that incorporate living microbial cells immobilized in a thin layer between an amperometric electrode and a porous (non-tortuous) membrane. In the example considered here, respiratory or photosynthetic electron-transport activity is monitored by using artificial redox mediators to divert electrons from the electron-transport systems to the working electrode poised at a suitable reducing potential. Such biosensors are being developed for a range of environmental monitoring applications. The mathematical model is used to demonstrate how the response of practical devices can be manipulated and to indicate potential pitfalls in the interpretation of toxicity assessment data derived by such biosensors.

Article information

Article type
Paper

Analyst, 1994,119, 197-201

Mathematical model of toxicity monitoring sensors incorporating microbial whole cells

B. G. D. Haggett, Analyst, 1994, 119, 197 DOI: 10.1039/AN9941900197

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements