Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Issue 56, 2014
Previous Article Next Article

Preparation of magnetic Pb(ii) and Cd(ii) ion-imprinted microspheres and their application in determining the Pb(ii) and Cd(ii) contents of environmental and food samples

Author affiliations

Abstract

A novel magnetic ion-imprinted polymer (MIIP) was prepared by inverse microemulsion polymerization using ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and 2,2-azo-bis-isobutyronitrile (AIBN) as the initiator. Fe3O4 particles were incorporated into the imprinted polymer matrix containing 4-vinyl pyridine and acrylate-modified Spirulina platensis as the functional monomers, Pb(II) and Cd(II) as double-templates. The MIIP product was characterized by Fourier-transform infrared spectroscopy, thermal gravimetric analysis and scanning electron microscopy and then evaluated for the magnetic solid-phase extraction of Pb(II) and Cd(II) from environmental and food samples. Inductively coupled plasma-optical emission spectrometry detection was also performed. The obtained MIIP showed the magnetic property, agglomerates of globular particles and rough surface morphologies. The maximum static adsorption capacities of MIIP for Pb(II) and Cd(II) were 108 and 56 mg g−1, respectively. The factors affecting the adsorption and separation of Pb(II) and Cd(II), namely, solution pH, adsorbent dosage, eluting solvent, and elution time, were investigated. Under the optimized conditions, the detection limits (S/N = 3) of the method were 0.1 and 0.08 μg kg−1 for Pb(II) and Cd(II), respectively. The relative standard deviations (RSDs) for 10-replicate detections of a soil sample were 3.3% and 3.7% for Pb(II) and Cd(II), respectively. Standard solutions containing Pb(II) and Cd(II) in the concentration range of 0.8 to 5000 μg kg−1 were analyzed by the proposed procedure and it was found that the calibration curve was linear in this range (R2 ≥ 0.999). The proposed method was successfully used to determine the Pb(II) and Cd(II) contents of cinnamon, lotus root and sweet potato with recovery rates ranging from 87.5% to 106%.

Graphical abstract: Preparation of magnetic Pb(ii) and Cd(ii) ion-imprinted microspheres and their application in determining the Pb(ii) and Cd(ii) contents of environmental and food samples

Back to tab navigation

Article information


Submitted
06 Mar 2014
Accepted
23 Jun 2014
First published
25 Jun 2014

RSC Adv., 2014,4, 29715-29723
Article type
Paper

Preparation of magnetic Pb(II) and Cd(II) ion-imprinted microspheres and their application in determining the Pb(II) and Cd(II) contents of environmental and food samples

S. Wei, Y. Liu, M. Shao, L. Liu, H. Wang and Y. Liu, RSC Adv., 2014, 4, 29715
DOI: 10.1039/C4RA01948B

Social activity

Search articles by author

Spotlight

Advertisements