Single-layer microfluidic device to realize hydrodynamic 3D flow focusing

Abstract

The recent rapid growth of microfluidic applications has witnessed the emergence of several particle flow focusing techniques for analysis and/or further processing. The majority of flow focusing techniques employ an external sheath fluid to achieve sample flow focusing independent of the flow rate, in contrast to sheath-free techniques. However, the introduction of a sheath fluid to surround the sample fluid has complicated the device design and fabrication, generally involving multi-layer fabrication and bonding of multiple polydimethylsiloxane (PDMS) layers. Several promising efforts have been made to reduce the complexity of fabrication. However, most of these methods involved the use of inertial/Dean effects, which in turn demanded the use of higher sample flow rates. In this paper, we report a method of flow focusing that uses a sheath fluid to enclose the sample in a single layer of PDMS, and that possesses applicability for a wide range of sample flow rates. This method of flow focusing uses abrupt channel depth variation and a shift of one of the sample-sheath junctions (termed as ‘junction-shift’) against the direction of the sample flow. This configuration serves to manipulate the sample fluid with respect to the sheath fluid and achieve the desired flow focusing. This design facilitates the attainment of 3D flow focusing in two sequential steps (depth-wise and then along the lateral direction) and in distinct regions, hence enabling the regions to be used in imaging and non-imaging flow cytometric applications, respectively. Simulations were performed to characterize and determine the optimum set of design parameters. Experimental demonstrations of this technique were carried out by focusing fluorescein dye and blood cells in flow.

Graphical abstract: Single-layer microfluidic device to realize hydrodynamic 3D flow focusing

Article information

Article type
Paper
Submitted
22 Jul 2016
Accepted
20 Sep 2016
First published
20 Sep 2016

Lab Chip, 2016,16, 4133-4141

Single-layer microfluidic device to realize hydrodynamic 3D flow focusing

G. Eluru, L. A. N. Julius and S. S. Gorthi, Lab Chip, 2016, 16, 4133 DOI: 10.1039/C6LC00935B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements