Tissue-on-chip (TOC) systems aim at replicating complex biological dynamics in vitro with the potential either to improve the understanding of human biology or to develop more accurate therapeutic strategies. To replicate faithfully the intricate interrelationships between cells and their surrounding microenvironment, the three-dimensional (3D) tissue model must possess a responsive extracellular matrix (ECM). ECM remodeling plays a pivotal role in guiding cells and tissues functions and such aspect is somewhat denied during in vitro studies. For this purpose, we fabricated a micro-perfusion bioreactor capable to sustain the viability of 3D engineered tissue models recapitulating the process of the native ECM deposition and assembly. Engineered human dermis micro-tissue precursors (HD-μTP) were used as building blocks to generate a final tissue. HD-μTP were loaded in the perfusion space of the micro-perfusion bioreactor and, under the superimposition of different fluid dynamic regimes and biochemical stimulation, they synthesized new collagen proteins that were, then, assembled in the perfusion space forming a continuum of cells embedded in their own ECM. The micro-perfusion bioreactor was fabricated to allow the on-line monitoring of the oxygen consumption and the assembly of the newly formed collagen network via real time acquisition of the second harmonic generation (SHG) signal. The possibility to detect the collagen reorganization due to both fluid dynamic and biochemical stimulation, let us to define the optimal perfusion configuration in order to obtain a TOC system based on an endogenous and responsive ECM.

Graphical abstract: A micro-perfusion bioreactor for on line investigation of ECM remodeling under hydrodynamic and biochemical stimulation

Article information


Submitted
04 Dec 2015
Accepted
02 Feb 2016
First published
02 Feb 2016

Lab Chip, 2016,16, 855-867
Article type
Paper

A micro-perfusion bioreactor for on line investigation of ECM remodeling under hydrodynamic and biochemical stimulation

A. Garziano, F. Urciuolo, G. Imparato, F. Martorina, B. Corrado and P. Netti, Lab Chip, 2016, 16, 855 DOI: 10.1039/C5LC01481F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.


Social activity

Search articles by author

Spotlight

Advertisements