Issue 6, 2012

Mechanical disruption of mammalian cells in a microfluidic system and its numerical analysis based on computational fluid dynamics

Abstract

The lysis of mammalian cells is an essential part of different lab-on-a-chip sample preparation methods, which aim at the release, separation, and subsequent analysis of DNA, proteins, or metabolites. Particularly for the analysis of compartmented in vivometabolism of mammalian cells, such a method must be very fast compared to the metabolic turnover-rates, it should not affect the native metabolite concentrations, and should ideally leave cell organelles undamaged. So far, no such a method is available. We have developed a microfluidic system for the effective rapid mechanical cell disruption and established a mathematical model to describe the efficiency of the system. Chinese hamster ovary (CHO) cells were disrupted with high efficiency by passing through two consecutive micronozzle arrays. Simultaneous cell compression and shearing led to a disruption rate of ≥90% at a sample flow rate of Q = 120 μL min−1 per nozzle passage, which corresponds to a mean fluid velocity of 13.3 m s−1 and a mean Reynolds number of 22.6 in the nozzle gap. We discussed the problem of channel clogging by cellular debris and the resulting flow instability at the micronozzle arrays. The experimental results were compared to predictions from Computational Fluid Dynamics (CFD) simulations and the critical energy dissipation rate for the disruption of the CHO cell population with known size distribution was determined to be 4.7 × 108 W m−3. Our model for the calculation of cell disruption on the basis of CFD-data could be applied to other microgeometries to predict intended disruption or undesired cell damage.

Graphical abstract: Mechanical disruption of mammalian cells in a microfluidic system and its numerical analysis based on computational fluid dynamics

Supplementary files

Article information

Article type
Paper
Submitted
23 Sep 2011
Accepted
03 Jan 2012
First published
06 Feb 2012

Lab Chip, 2012,12, 1071-1077

Mechanical disruption of mammalian cells in a microfluidic system and its numerical analysis based on computational fluid dynamics

M. Wurm and A. Zeng, Lab Chip, 2012, 12, 1071 DOI: 10.1039/C2LC20918G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements