Issue 17, 2011

An electrode array for electrochemical immuno-sensing using the example of impedimetric tenascin C detection

Abstract

Electrochemical biosensors allow simple, fast and sensitive analyte detection for various analytical problems. Especially immunosensors are favourable due to specificity and affinity of antigen recognition by the associated antibody. We present a novel electrode array qualified for parallel analysis and increased sample throughput. The chip has nine independent sample chambers. Each chamber contains a circular gold working electrode with a diameter of 1.9 mm that is surrounded by a ring-shaped auxiliary electrode with a platinum surface. The corresponding silver/silver chloride reference electrodes are embedded in a sealing lid. The chip is open to the full range of electrochemical real-time detection methods. Among these techniques, impedance spectroscopy is an attractive tool to detect fast and label-free interfacial changes originating from the biorecognition event at the electrode surface. The capabilities of the novel electrode array are demonstrated using the example of tumour marker tenascin C detection. This glycoprotein of the extracellular matrix is expressed in cancerous tissues, especially in solid tumours such as glioma or breast carcinoma. Electrodes covered with specific antibodies were exposed to tenascin C containing samples. Non-occupied binding sites were identified using a secondary peroxidase-conjugated antibody that generated an insoluble precipitate on the electrode in a subsequent amplification procedure. The charge transfer resistance obtained from impedimetric analysis of ferri-/ferrocyanide conversion at the electrode served as analytic parameter. This assay detected 14 ng (48 fmol) tenascin C that is sufficient for clinical diagnostics. The electrode surface could be regenerated at least 20-fold without loss of its analytical performance.

Graphical abstract: An electrode array for electrochemical immuno-sensing using the example of impedimetric tenascin C detection

Article information

Article type
Paper
Submitted
30 Mar 2011
Accepted
06 Jun 2011
First published
13 Jul 2011

Lab Chip, 2011,11, 2884-2892

An electrode array for electrochemical immuno-sensing using the example of impedimetric tenascin C detection

A. Steude, S. Schmidt, A. A. Robitzki and O. Pänke, Lab Chip, 2011, 11, 2884 DOI: 10.1039/C1LC20267G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.