Issue 5, 2014

On-line flow injection solid phase extraction using oxidised carbon nanotubes as the substrate for cold vapour-atomic absorption determination of Hg(ii) in different kinds of water

Abstract

A study was carried out to investigate the concentrations of Hg(II) in different categories of water samples at ng L−1 levels. The capabilities of oxidised carbon nanotubes (ox-CNTs) were studied to assess if this substrate serves as an efficient material for Hg(II) preconcentration using an on-line flow injection cold vapour-atomic absorption spectrometry (FI-CV-AAS) system. Carbon nanotubes are characterized by a marked tendency to aggregate, which negatively affects the retention of Hg whenever integrated in flow systems as a packed column. For this reason, the preconcentration was carried out in a microcolumn filled with a mixture of ox-CNTs and a low molecular weight polyethylene. The preparation of the microcolumn was studied in detail. Concerning column design, the best performance was achieved when packing the substrate in a microcolumn of 2.25 mm (i.d.) × 20 mm length. The effect of chemical and physical parameters including the pH of the solutions, the eluent type and the concentration was systematically examined. Mercury was retained at pH 5.0 and 15% (v/v) HCl was the best alternative for Hg(II) elution. Under optimal conditions, the adsorption capacity of the substrate was found to be 3.2 mg g−1 reaching a preconcentration factor (PF) of 150. The high adsorption capacity of this substrate allowed reaching a detection limit (3σ) of 1.9 ng L−1, when using a sorbent column containing only 1.0 mg of ox-CNTs. The limit of quantification (10σ) resulted to be 6.3 ng L−1. Precision, expressed as relative standard deviation (RSD), turned out to be 1.6% at the 0.1 μg L−1 level (n = 8). The system was evaluated for quantitative determination of Hg in river water, sea water and effluents.

Graphical abstract: On-line flow injection solid phase extraction using oxidised carbon nanotubes as the substrate for cold vapour-atomic absorption determination of Hg(ii) in different kinds of water

Article information

Article type
Paper
Submitted
19 Dec 2013
Accepted
13 Feb 2014
First published
13 Feb 2014

J. Anal. At. Spectrom., 2014,29, 880-885

Author version available

On-line flow injection solid phase extraction using oxidised carbon nanotubes as the substrate for cold vapour-atomic absorption determination of Hg(II) in different kinds of water

B. Parodi, A. Londonio, G. Polla, M. Savio and P. Smichowski, J. Anal. At. Spectrom., 2014, 29, 880 DOI: 10.1039/C3JA50396H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.