Issue 2, 2011

A TIMS-based method for the high precision measurements of the three-isotope potassium composition of small samples

Abstract

A novel thermal ionization mass spectrometry (TIMS) method for the three-isotope analysis of K has been developed, and ion chromatographic methods for the separation of K have been adapted for the processing of small samples. The precise measurement of K-isotopes is challenged by the presence of large isotope ratios in common K, and the accuracy of such measurements is compromised by isobaric interference and abundance sensitivity related issues. The combined expanded dynamic range and improved signal/noise ratio of a Triton TIMS with an adapted amplifier setup however allows measurements in the theoretically poisson-noise dominated intensity regime, while the high sensitivity of the thermal ionization-based source towards K allows this intensity regime to be reached, even with small samples. Analyses of 150 ng K samples of terrestrial basalts shows 2 s.d. 100 ppm-level or better reproducibility for mass fractionation corrected 41K/39K ratios, while 10 ng K samples show 2 s.d. 200 ppm-level or better for mass fractionation corrected 41K/39K ratios. The described methods are suitable for the high precision determination of internally mass fractionation corrected isotope anomalies in small samples, such as those recoverable from refractory inclusions in chondritic meteorites, or other low-level, rare or valuable materials. For meteoritic inclusions in particular, this has applications in the determination of 41K excesses, attributable to the former presence of 41Ca, and the reproducibility-levels reached are sufficient to resolve bulk radiogenic anomalies at the level suggested by prior ion microprobe studies. In addition to such radiometric applications, the K-isotope composition is potentially sensitive to cosmic ray overprint, and as such may be used to assess the level of cosmic ray irradiation in various extra-terrestrial materials.

Graphical abstract: A TIMS-based method for the high precision measurements of the three-isotope potassium composition of small samples

Article information

Article type
Paper
Submitted
07 Jul 2010
Accepted
22 Oct 2010
First published
11 Nov 2010

J. Anal. At. Spectrom., 2011,26, 366-377

A TIMS-based method for the high precision measurements of the three-isotope potassium composition of small samples

D. Wielandt and M. Bizzarro, J. Anal. At. Spectrom., 2011, 26, 366 DOI: 10.1039/C0JA00067A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements