Issue 3, 2008

Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry

Abstract

Four candidate ground bone reference materials (NYS RMs 05-01 through 04), were produced from lead-dosed bovine and caprine sources, and characterized by interlaboratory study. The consensus value (X) and expanded standard uncertainty (UX) were determined from the robust average and standard deviation of the participants’ data for each NYS RM 05-01 through 04. The values were 1.08 ± 0.04, 15.3 ± 0.5, 12.4 ± 0.5, and 29.9 ± 1.1 µg g−1 Pb, respectively. Youden plots of z-scores showed a statistically significant correlation between the results for pairs of NYS RM 05-02 through 04, indicating common sources of between-laboratory variation affecting reproducibility. NYS RM 05-01 exhibited more random variability, affecting repeatability at low concentration. Some participants using electrothermal atomic absorption spectrometry (ETAAS) exhibited a negative bias compared to the all-method consensus value. Other methods used included inductively coupled plasma mass spectrometry (ICP-MS), isotope dilution (ID-) ICP-MS, and ICP atomic (optical) emission spectroscopy (-OES). The NYS RMs 05-01 through 04 were subsequently re-analyzed in house using double ID-ICP-MS to assign certified reference values (C) and expanded uncertainty (UC) of 1.09 ± 0.03, 16.1 ± 0.3, 13.2 ± 0.3 and 31.5 ± 0.7, respectively, indicating a low bias in the interlaboratory data. SRM 1486 Bone Meal was analyzed for measurement quality assessment, obtaining results in agreement with the certified values within the stated uncertainty. Analysis using a primary reference method based on ID-ICP-MS with full quantification of uncertainty calculated according to ISO guidelines provided traceability to SI units.

Graphical abstract: Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry

Article information

Article type
Paper
Submitted
16 Jul 2007
Accepted
25 Oct 2007
First published
12 Nov 2007

J. Anal. At. Spectrom., 2008,23, 298-308

Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry

D. J. Bellis, K. M. Hetter, M. F. Verostek and P. J. Parsons, J. Anal. At. Spectrom., 2008, 23, 298 DOI: 10.1039/B710808G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements