Issue 11, 2004

Determination of selenomethionine in yeast using CNBr derivatization and species specific isotope dilution GCICP-MS and GC-MS

Abstract

A comparison of several published and in-house methods for quantitation of selenomethionine (SeMet) in yeast was undertaken using species specific isotope dilution (ID) with a 74Se enriched SeMet. An in-house method was based on digestion of samples by refluxing for 16 h with 4 M methanesulfonic acid, derivatization of SeMet with cyanogen bromide and extraction into chloroform for determination by GC ICP-MS. Concentrations of 3434 ± 19 and 3419 ± 15 μg g−1 (one standard deviation, n = 6) with relative standard deviations of 0.55% and 0.42% for SeMet were obtained in yeast based on measurement of 78Se/74Se and 82Se/74Se ratios, respectively, in agreement with a value of 3417 ± 27 μg g−1 (one standard deviation, n = 6) obtained using ID GC-MS detection based on the ratio of 106/100 of SeCN+ ion. The SeMet accounts for 67% of the total Se in the sample. A method detection limit (three standard deviations) of 0.9 μg g−1 was estimated for SeMet based on a 0.25 g subsample. Significantly lower concentrations of 2220 ± 7 and 2215 ± 9 μg g−1 (one standard deviation, n = 4) with RSDs of 0.30 and 0.41% were obtained by ID GC ICP-MS using 78Se/74Se and 82Se/74Se ratios, respectively, following digestion with 2% SnCl2 in 0.1 M HCl and reaction with CNBr to form volatile CH3SeCN. Similar SeMet concentrations of 3415 ± 200 and 3447 ± 198 μg g−1 (one standard deviation, n = 6) and significantly degraded precisions of 5.86 and 5.74%, respectively, were obtained in yeast using 78Se/74Se and 82Se/74Se ratios, respectively, following digestion with 4 M methanesulfonic acid and derivatization with methyl chloroformate.

Article information

Article type
Paper
Submitted
12 Jul 2004
Accepted
11 Aug 2004
First published
16 Sep 2004

J. Anal. At. Spectrom., 2004,19, 1448-1453

Determination of selenomethionine in yeast using CNBr derivatization and species specific isotope dilution GC ICP-MS and GC-MS

L. Yang, R. E. Sturgeon, W. R. Wolf, R. J. Goldschmidt and Z. Mester, J. Anal. At. Spectrom., 2004, 19, 1448 DOI: 10.1039/B410543E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements