Issue 7, 2003

Determination of phosphorus in phosphorylated deoxyribonucleotides using capillary electrophoresis and high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell

Abstract

The determination of phosphorus in a biologically relevant sample matrix such as DNA is described. The analytical methodology used is based on a robust on-line coupling of capillary electrophoresis (CE) or high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry, equipped with an octopole reaction system (ORS-ICP-MS). Polyatomic ions formed in the plasma and the interface region of the ICP-MS that interfere with the determination of P at mass 31 were minimised by the addition of helium to the collision cell. Instrumental detection limits of 125 ng L−1 for 31P, and in the range of 18 to 49 ng L−1 for the other trace elements, were achieved under the conditions described. In order to demonstrate the high separation and detection efficiency of the system, the method developed has been applied to the element specific detection of phosphorus in monophosphorylated deoxynucleotides and to enzymatically digested calf thymus DNA after CE and HPLC separation, respectively. Both hyphenated techniques provide baseline separation of the four deoxynucleotide monophosphates (dNMP), which are present in the DNA chain. With CE-ICP-MS, detection limits for phosphorus down to 53 µg L−1 (2′-deoxyguanosin-5′-monophosphate, dAMP) (corresponding to 0.6 pg P absolute) have been achieved. RSDs of the migration times were about 5%. Using HPLC-ICP-MS, detection limits down to 3 µg L−1 (2′-deoxythymidine-5′-monophosphate, dTMP) (corresponding to 0.03 ng P absolute) were obtained. The migration/elution order of the deoxynucleotides investigated was obtained by comparison with the migration/retention times of commercially available dNMP's. Furthermore it was checked if HPLC-ESI-MS can be operated under the same chromatographic conditions for the confirmation of the elution order and for the characterisation of unknown peaks. Finally, flow injection analysis (FIA) was used for the quantification of the phosphorus content in the dNMP samples. Using FIA, detection limits for phosphorus of 2.5 µg L−1 corresponding to 25 pg phosphorus absolute were achieved.

Article information

Article type
Paper
Submitted
04 Mar 2003
Accepted
08 Apr 2003
First published
09 May 2003

J. Anal. At. Spectrom., 2003,18, 708-713

Determination of phosphorus in phosphorylated deoxyribonucleotides using capillary electrophoresis and high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell

D. Pröfrock, P. Leonhard and A. Prange, J. Anal. At. Spectrom., 2003, 18, 708 DOI: 10.1039/B302445H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements