Issue 1, 2002

Abstract

A direct injection high efficiency nebulizer (DIHEN) was modified for µLC-ICP-MS by inserting an additional internal capillary with od 90 µm and id 20 µm to minimize the interface dead volume. The modified DIHEN was compared with a conventional microflow nebulizer with a spray chamber interface with respect to sensitivity, signal stability and organic modifier dependency at flow rates ranging from 0.5 to 5 µl min−1. Although the modified DIHEN was slightly less sensitive, its signal stability was superior, its modifier dependency was less pronounced and its chromatographic resolution was much better due to its extremely small dead volume. These characteristics were demonstrated by the analysis of a mixture of synthetic phosphopeptides (31P detection) and synthetic thyroxine (127I detection). The influence of an organic modifier in the analyte solvent on the detection sensitivity was tested using the bioelements sulfur, phosphorus and iodine as examples. Phosphorus and iodine show an increased signal proportional to the amount of organic modifier with an intensity maximum of between 40% and 60% of modifier, which corresponds to a metal-like characteristic. For the detection of sulfur this characteristic is counteracted by a signal suppression effect proportional to the amount of organic modifier, which is caused by the formation of polyatomic species such as sulfur oxide.

Article information

Article type
Paper
Submitted
07 Sep 2001
Accepted
12 Nov 2001
First published
06 Dec 2001

J. Anal. At. Spectrom., 2002,17, 21-26

Modified direct injection high efficiency nebulizer with minimized dead volume for the analysis of biological samples by micro- and nano-LC-ICP-MS

M. Wind, A. Eisenmenger and W. D. Lehmann, J. Anal. At. Spectrom., 2002, 17, 21 DOI: 10.1039/B108153P

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements