Issue 5, 2000

Abstract

The purpose of this work was to compare an ultrasonic nebulizer (USN) with a cross-flow nebulizer (CFN) for selenium speciation with inductively coupled plasma mass spectrometry (ICP-MS) detection. The influence of instrumental parameters as well as composition of the solvent on the selenium species, trimethylselenonium ion (TMSe), selenomethionine (SeMet), selenite and selenate, were studied. Using the CFN, there was no difference in sensitivity of the four selenium species and the species responded similarly to all changes. In the USN, sensitivity increased between 14 and 21 times for the species. Selenate and TMSe showed the largest increase in sensitivity while selenite and SeMet showed lower increases. The species behaved differently on changing the heat temperature of the USN and the pH of the solutions. When the carbon enhancement effect was exploited by adding 3% methanol, the increase in sensitivity with the USN was between 2.5 and 8.7 times. It was observed that yttrium could not be used as internal standard in the USN as the sensitivity of this element was dependent on pH as well as the presence of different selenium species, while rhodium was unaffected by these parameters. The USN was found inapplicable for normal sample uptake as memory effects were severe and low blank values, therefore, difficult to obtain. Thus, this nebulizer could only be used for transient signals. When coupling the nebulizers to an anion-exchange chromatographic system, peak widths of the chromatographic signals were comparable. The sensitivity with the USN was 10 times larger than with the CFN. Detection limits, however, were not decreased correspondingly. Detection limits calculated on the basis of 82Se were between 0.15 and 0.24 µg l−1 Se with the USN, while they were between 0.43 and 1.6 µg l−1 Se with the CFN.

Article information

Article type
Paper
Submitted
11 Nov 1999
Accepted
06 Mar 2000
First published
31 Mar 2000

J. Anal. At. Spectrom., 2000,15, 499-506

Comparison of an ultrasonic nebulizer with a cross-flow nebulizer for selenium speciation by ion-chromatography and inductively coupled plasma mass spectrometry

B. Gammelgaard and O. Jøns, J. Anal. At. Spectrom., 2000, 15, 499 DOI: 10.1039/A908975F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements