Issue 11, 1994

Determination of ultra-trace amounts of cobalt in ocean water by laser-excited atomic fluorescence spectrometry in a graphite electrothermal atomizer with semi on-line flow injection preconcentration

Abstract

A method has been developed for the determination of trace and ultra-trace amounts of cobalt in sea-water. Samples of CASS-2 Nearshore Seawater and NASS-4 Open Ocean Water reference materials from the National Research Council of Canada were employed. Laser-excited atomic fluorescence spectrometry in an electrothermal atomizer (ET-LEAFS) was used, and integrated with semi on-line flow injection microcolumn preconcentration. For cobalt, the effects of pH on the preconcentration efficiency, the concentration of the chelating agent and the distribution of cobalt in the ethanol eluate were studied. A bonded silica, with octadecyl functional groups (C18) in a 10 µl column, was employed for preconcentration of cobalt in ocean water. Ocean water volumes of 0.40 and 1.00 ml were required for the determination of cobalt in CASS-2 and NASS-4, respectively. These volumes were almost two orders of magnitude smaller than those required by inductively coupled plasma mass spectrometry and some other competitive techniques. The preconcentration factors were 5- and 12.5-fold for CASS-2 and NASS-4, respectively. The detection limits (3s), based on 12.5-fold preconcentration, were 0.08 and 1.0 ng l–1 for cobalt in aqueous standard solutions and in Ocean Water Reference Materials, respectively. Results for the determination of cobalt in CASS-2 and NASS-4 showed that there were no significant differences between the certified values and the measured values, based on Student's t-test at the 95% confidence level. The relative standard deviations for the determinations of the concentrations of cobalt in CASS-2 and NASS-4 were 9 and 13%, respectively.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1994,9, 1195-1202

Determination of ultra-trace amounts of cobalt in ocean water by laser-excited atomic fluorescence spectrometry in a graphite electrothermal atomizer with semi on-line flow injection preconcentration

A. I. Yuzefovsky, R. F. Lonardo, M. Wang and R. G. Michel, J. Anal. At. Spectrom., 1994, 9, 1195 DOI: 10.1039/JA9940901195

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements