Isotope ratio measurement of lead, neodymium and neodymium–samarium mixtures, Hafnium and Hafnium–Lutetium mixtures with a double focusing multiple collector inductively coupled plasma mass spectrometer

Abstract

An inductively coupled plasma (ICP) source coupled to a double focusing magnetic sector mass analyser equipped with seven Faraday detectors has been used to measure the isotopic ratios of lead reference materials using a thallium correction technique. The addition of thallium to the lead standards and the subsequent simultaneous measurement of the thallium and lead isotopes allowed a correction for mass discrimination. Measurement of six samples of National Institute of Standards and Technology (NIST)(formerly National Bureau of Standards) Standard Reference Material Pb-982 revealed 208Pb:204Pb=36.702 ± 0.022, 207Pb:204Pb=17.141±0.009 and 206Pb:204Pb=36.711±0.021 compared with the NIST certified values of 36.744±0.050, 17.159±0.025 and 36.738±0.037, respectively. All errors are given as 2σ. The measurement of each sample used approximately 200 ng of lead and took 100 s. Measurement of six neodymium samples (obtained from Scripps Institute of Oceanography, La Jolla, CA, USA), where internal normalization to 146Nd:145Nd is possible, revealed a 143Nd:144Nd ratio of 0.511825±0.000039 compared with the accepted value of 0.511859. Measurement of six La Jolla neodymium samples contaminated with a similar concentration of samarium revealed a 143Nd:144Nd ratio of 0.511854±0.000059. The measurement of each mixed sample used approximately 100 ng of neodymium. Similarly measurement of six samples of Johnson Matthey Company (JMC) 475 Hafnium, normalized to 179Hf:177Hf, revealed a 176Hf:177Hf ratio of 0.282194±0.000020 compared with the accepted value of 0.282195±0.000015. Measurement of six samples of JMC 475 Hafnium contaminated with a similar concentration of lutetium revealed a 176Hf:177Hf ratio of 0.282213±0.000023. The measurement of each mixed sample used approximately 400 ng of hafnium.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1993,8, 19-23

Isotope ratio measurement of lead, neodymium and neodymium–samarium mixtures, Hafnium and Hafnium–Lutetium mixtures with a double focusing multiple collector inductively coupled plasma mass spectrometer

A. J. Walder, I. Platzner and P. A. Freedman, J. Anal. At. Spectrom., 1993, 8, 19 DOI: 10.1039/JA9930800019

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements