Jump to main content
Jump to site search
Access to RSC content Close the message box

Continue to access RSC content when you are not at your institution. Follow our step-by-step guide.


Volume 213, 2019
Previous Article Next Article

Chemically addressed switching measurements in graphene electrode memristive devices using in situ XPS

Author affiliations

Abstract

The memristor has been the topic of heated research activity since the Pt/TiO2/TiOx/Pt structure was reported by Hewlett-Packard Labs. The characteristics of memristors such as the pinched hysteresis loops and time and input signal-dependent memristance are due to the drift of positively charged oxygen vacancies in the TiOx layer. While different modes of switching behaviour have been characterized, observing the switching as it happens with in situ measurements using X-ray photoelectron spectroscopy (XPS) can allow a better understanding of the device operation. The setup used in this work enables the application of voltage signals of different frequencies and amplitudes and observing the hysteresis seen in the IV plane through chemical addressing. The measurements were conducted on Pt/TiO2/TiOx/graphene structures. The single layer graphene, utilized as a top electrode, effectively acts as a transparent electrode in that the layer beneath it can be observed to a depth of ∼10 nm in XPS. This allows for the observation of the changes in the binding energies of C 1s, Ti 2p and O 1s. By comparing the variation in the binding energy of Ti 2p to that of C 1s, and observing how the variation changes for different excitation signals (at different frequency and amplitudes), it is possible to inspect the effect of the oxygen vacancy drift. We employed a variety of input signals with varying frequency and amplitudes in order to test the memristive devices thoroughly: sine wave, triangular wave and DC bias. Graphene has been attracting attention due to its intriguing optoelectronic properties. This study utilizes graphene as a transparent top electrode for in situ measurements in XPS to observe chemically-addressed memristive hysteresis while an excitation signal is being applied to the device.

Graphical abstract: Chemically addressed switching measurements in graphene electrode memristive devices using in situ XPS

Back to tab navigation

Associated articles

Article information


Submitted
19 Jul 2018
Accepted
06 Aug 2018
First published
06 Aug 2018

Faraday Discuss., 2019,213, 231-244
Article type
Paper

Chemically addressed switching measurements in graphene electrode memristive devices using in situ XPS

I. Köymen, P. Aydoğan Göktürk, C. Kocabaş and Ş. Süzer, Faraday Discuss., 2019, 213, 231
DOI: 10.1039/C8FD00129D

Social activity

Search articles by author

Spotlight

Advertisements