Issue 12, 2012

Nonlinearity in the relationship between bone lead concentrations and CBLI for lead smelter employees

Abstract

494 smelter employees from New Brunswick participated in a bone lead survey conducted by McMaster University in 2008, using the four element “clover-leaf” geometry germanium detector system. The employees were measured at two different bone sites, tibia and calcaneus, each measurement lasting 30 minutes. Scattered photons, including Pb X-rays, were collected by the germanium detectors located behind the 109Cd source. A strong positive correlation was observed between tibia and calcaneus lead concentrations. Having been provided with blood lead levels, a cumulative blood lead index (CBLI) was generated. The employees were classified into four groups based on their date of hire, and their CBLI levels were compared to their tibia and calcaneus lead concentrations in the different groups. The slopes of bone Pb versus CBLI varied amongst groups, with those hired earliest showing the steepest slopes. This could be taken to imply a non-linearity in the uptake of Pb by bone from blood. In this paper, the association of the bone lead concentrations versus CBLI has been expressed by a polynomial function for the whole group of employees.

Graphical abstract: Nonlinearity in the relationship between bone lead concentrations and CBLI for lead smelter employees

Article information

Article type
Paper
Submitted
04 Aug 2012
Accepted
25 Oct 2012
First published
14 Nov 2012

J. Environ. Monit., 2012,14, 3267-3275

Nonlinearity in the relationship between bone lead concentrations and CBLI for lead smelter employees

S. Behinaein, D. R. Chettle, L. M. Egden, F. E. McNeill, G. Norman, N. Richard and S. Stever, J. Environ. Monit., 2012, 14, 3267 DOI: 10.1039/C2EM30652B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements