Issue 7, 2012

Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples

Abstract

Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO2, the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO2 particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO2 measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb2+, particulate Pb(II) carbonate and PbO2 in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb2+, spiked particulate Pb(II) carbonate and in situ formed or spiked PbO2. Recovery tests showed that the proposed procedure and the USEPA method can achieve 93–112% and 86–103% recoveries respectively for samples containing low PbO2 concentrations (0.018–0.076 mg Pb per L). For samples containing higher concentrations of PbO2 (0.089–1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85–115%) while the proposed method can achieve satisfactory recoveries (91–111%) and differentiate the soluble Pb2+, particulate Pb(II) carbonate and PbO2.

Graphical abstract: Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples

Article information

Article type
Paper
Submitted
30 Nov 2011
Accepted
16 Apr 2012
First published
17 Apr 2012

J. Environ. Monit., 2012,14, 1846-1852

Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples

Y. Zhang, D. Ng and Y. Lin, J. Environ. Monit., 2012, 14, 1846 DOI: 10.1039/C2EM10962J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements