Issue 7, 2007

Thermally induced filter bias in TEOM mass measurement

Abstract

Researchers at the National Institute for Occupational Safety and Health (NIOSH) have long used stationary tapered element oscillating microbalances (TEOMs®) in laboratory settings. They have served to assess the mass concentration of laboratory-generated particulates in experimental dust chambers and they provide a reference method for comparison with other particulate-measuring instruments. Current NIOSH research is focused on further adapting TEOM technology as a wearable personal dust monitor (PDM) for coal mining occupations. This investigation’s goal is to help identify, quantify, and provide means for resolving certain TEOM-related error. The present research investigated bias caused by thermal effects on filter assemblies. New filters used in the PDM for 8 h tests show an average positive bias of 25.5 μg, while similar tests of equivalent filters used in two 1400A model TEOMs show an average positive bias of 34.3 μg. The derived bias values allow correction of previously collected biased data. Also, pre-heating the filters for 24 h at 46 °C shows significant bias reduction, with PDM pre-heated filters subsequently averaging −3.3 μg and 1400A TEOM filters averaging 5.9 μg. On a single-point comparison to gravimetric sampling, a 25.5 μg bias is only significant at low mass loadings. At 2.5 mg, this bias represents a negligible 1% of the mass measurement. If ordinary linear regression is used, the bias is still insignificant. However, if the more valid weighted linear regression is used, it gives more weight to the smaller dependent variable values, which are more impacted by the bias. Consequently, what is 1% bias on a single high-mass value can translate into a larger bias percentage at high-mass values when performing a weighted regression on data that include a large number of low-mass values.

Graphical abstract: Thermally induced filter bias in TEOM mass measurement

Article information

Article type
Paper
Submitted
23 Mar 2007
Accepted
18 May 2007
First published
13 Jun 2007

J. Environ. Monit., 2007,9, 760-767

Thermally induced filter bias in TEOM mass measurement

S. J. Page, D. P. Tuchman and R. P. Vinson, J. Environ. Monit., 2007, 9, 760 DOI: 10.1039/B704424K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements