Image-based luminescence detection for quantitative determinations in continuous flow analysis microsystems

Abstract

The use of an ordinary webcam to detect luminescence in continuous flow analysis microsystems is described, as well as evaluation of the proposed strategy for determining acetaminophen in tablets and to assess the hardness of mineral waters. Lab-made microfluidic devices were arranged in a box to avoid external light influence and the camera was fixed to the top of the box, aligned to flow cells, in which RGB detection was performed at pre-selected pixels of real time images. For determining acetaminophen in tablets, the merging zones principle was used to mix the samples or drug standard solutions (0.10–0.50 mg mL−1) with OCl−1 solution (0.05% (m/v)) prior to the confluence with luminol (2.0 mmol L−1) and chemiluminescence readings. The analytical curve based on the quenching of the blue color response showed a linear relationship (R2 = 0.996) and the LOD was estimated to be 0.03 mg mL−1. In addition, no significant differences were found on comparison of the contents of drugs determined by the proposed method with those on medicine labels. Fluorometric determination of mineral waters' hardness was performed using a blue LED and optical fibers as an excitation source. Sample or standard solutions (0.12–0.62 mmol L−1 in Ca2+) were merged with 0.4 g L−1 calcein solution and propelled to the detection zone. The response to green color showed a linear relationship (R2 = 0.994) with the studied concentrations, and an LOD of 0.08 mmol L−1 was estimated for the method. Also, the water hardness determined by the proposed method offered no significant difference at the 95% confidence level when compared with results obtained with complexometric titrations.

Graphical abstract: Image-based luminescence detection for quantitative determinations in continuous flow analysis microsystems

Article information

Article type
Paper
Submitted
08 Sep 2018
Accepted
05 Nov 2018
First published
05 Nov 2018

Anal. Methods, 2018,10, 5571-5576

Image-based luminescence detection for quantitative determinations in continuous flow analysis microsystems

H. de Souza Ramos Pontes Moura, A. R. Mól, T. R. Sampaio and A. Fonseca, Anal. Methods, 2018, 10, 5571 DOI: 10.1039/C8AY01973H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements