Issue 21, 2017

Calibration transfer of flour NIR spectra between benchtop and portable instruments

Abstract

This work reports on the use of different strategies of calibration transfer to determine crude protein and fiber properties in samples of functional flours analyzed with benchtop (primary) and portable (secondary) NIR instruments. For this purpose, methods of direct standardization (DS) and reverse standardization (RS) were used on a different number of transfer samples. Calibration models based on the following regression strategies were evaluated: partial least squares using a full spectrum (PLSfull spectrum); PLS with significant regression coefficients selected by the Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with previous selection of variables by the successive projection algorithm (MLR/SPA). The performance of calibration models was assessed according to Root Mean Square Error of Prediction (RMSEP) values obtained in a prediction subset measured on a secondary instrument before and after standardization procedures. Before standardization, all the calibration models presented high RMSEP values for the prediction samples measured on the secondary instrument to determine both crude protein and fibers. After the direct standardization, a considerable decrease of the RMSEP values was observed in the PLSfull spectrum and MLR/SPA calibration models developed for crude protein determination. For fiber determination, the lowest RMSEP value was obtained using the PLSfull spectrum model with RS, although no statistically significant difference was found between the RMSEP values obtained for PLS/JK and MLR/SPA models.

Graphical abstract: Calibration transfer of flour NIR spectra between benchtop and portable instruments

Article information

Article type
Paper
Submitted
14 Feb 2017
Accepted
26 Apr 2017
First published
26 Apr 2017

Anal. Methods, 2017,9, 3184-3190

Calibration transfer of flour NIR spectra between benchtop and portable instruments

A. L. Bizerra Brito, A. V. Pereira Santos, K. D. Tavares Melo Milanez, M. José Coelho Pontes and L. F. Bezerra Lira Pontes, Anal. Methods, 2017, 9, 3184 DOI: 10.1039/C7AY00391A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements