High performance liquid chromatography-quantitative nuclear magnetic resonance (HPLC-qNMR) with a two-signal suppression method for purity assessment of avermectin B1a

Abstract

HPLC-qNMR (high performance liquid chromatography-quantitative nuclear magnetic resonance) is a technology with great potential, which combines the high separation capability of HPLC and the high qualitative/quantitative analysis capability of NMR. It overcomes the problem of overestimation in qNMR and the problem of unavailable reference materials in HPLC. But its current application is narrow due to the lack of a good method to eliminate the vast amount of signals from the protons of the mobile phase. This study proposed a new HPLC-qNMR method for a natural complex pesticide (avermectin B1a). Common solvents (CH3CN and H2O = 70 : 30) are introduced as the HPLC mobile phase, which reduces the cost to make its wider application possible. The solution mixture of the sample and the internal standard (benzoic acid) was separated by HPLC. Only the eluent of the target analyte (avermectin B1a) and the eluent of the internal standard were collected in one vial, and then were determined by qNMR with a new signal suppression method to suppress two signals from CH3CN and H2O simultaneously. After the optimization of key parameters for qNMR, the mean and uncertainty (94.63% ± 1.97%) is consistent with that from the mass balance method based on many instruments (93.70% ± 0.46%). The bias is no more than 1%. This method can be widely applied in the future due to its efficient separation capability, high qualitative/quantitative capability, very low cost, rapid operation and good accuracy.

Graphical abstract: High performance liquid chromatography-quantitative nuclear magnetic resonance (HPLC-qNMR) with a two-signal suppression method for purity assessment of avermectin B1a

Article information

Article type
Paper
Submitted
26 Feb 2016
Accepted
06 May 2016
First published
09 May 2016

Anal. Methods, 2016,8, 4482-4486

Author version available

High performance liquid chromatography-quantitative nuclear magnetic resonance (HPLC-qNMR) with a two-signal suppression method for purity assessment of avermectin B1a

T. Huang, W. Zhang, X. Dai, N. Li, L. Huang, C. Quan, H. Li and Y. Yang, Anal. Methods, 2016, 8, 4482 DOI: 10.1039/C6AY00570E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements