Issue 11, 2015

Development of a multicommuted flow analysis procedure for simultaneous determination of sulfate and chloride in petroleum coke employing a homemade syringe pump and a LED-based photometer

Abstract

The current paper deals with procedures for simultaneous determination of sulfate and chloride in petroleum coke samples after microwave-induced combustion (MIC), which were implemented employing a multicommuted flow analysis process. The setup comprised a homemade syringe pump and two individual flow system manifolds, each coupled to a homemade LED-based photometer. Dedicated software enabled sampling and reading steps to be performed while displacing the syringe pistons forward and backward, allowing a sampling rate of 150 determinations per hour. The procedure for sulfate determination was based on the reaction of barium with sulfate and turbidimetric detection, while the procedure for chloride determination was based on the photometric mercury/thiocyanate method. In order to investigate the feasibility of both the equipment setup and the proposed procedures, samples of petroleum coke previously digested by microwave induced combustion (MIC) were analyzed. For accuracy assessment, samples were also analyzed employing ion chromatography and inductively coupled plasma optical emission spectrometry to determine chloride and sulfate, respectively. The paired t-test indicated no significant difference between the results for our method and those of the established methods, at a 95% confidence level. Linear responses (r = 0.999) were obtained with concentrations ranging from 10 to 700 mg L−1 for sulfate, and from 0.25 to 10 mg L−1 for chloride.

Graphical abstract: Development of a multicommuted flow analysis procedure for simultaneous determination of sulfate and chloride in petroleum coke employing a homemade syringe pump and a LED-based photometer

Article information

Article type
Paper
Submitted
04 Mar 2015
Accepted
01 May 2015
First published
05 May 2015

Anal. Methods, 2015,7, 4769-4779

Author version available

Development of a multicommuted flow analysis procedure for simultaneous determination of sulfate and chloride in petroleum coke employing a homemade syringe pump and a LED-based photometer

F. G. Santos, A. C. Pereira, S. M. Cruz, C. A. Bizzi, É. M. M. Flores and B. F. Reis, Anal. Methods, 2015, 7, 4769 DOI: 10.1039/C5AY00565E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements