Detection ofphthalates in water using ultra performance liquid chromatography-electrospray ionizationtandem mass spectrometry MRM mode– ‘ghost peaks’ and measurement methodology

Abstract

In the analysis of phthalates, specifically diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBP), and diethylhexyl phthalate (DEHP) using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS), ‘ghost peaks’ appeared when a gradient liquid chromatography elution mode was employed. A systematic diagnostic analytical protocol was designed to show that the source of the persistent ‘ghost peaks’, which jeopardized a quantitative analysis of these endocrine disruptors was the mobile phase. A trace amount of DEHP in the mobile phase, either from ultrapure water or organic solvent, was responsible for the observed phenomenon. In contrast to gradient elution, isocratic chromatographic elution mode (ICEM) was found to be free of the problem at the expense of less effective separation of DBP and BBP. Thus, a detection method for analyzing the phthalates is proposed based on ICEM and the multiple reaction monitoring (MRM) mode with multi-channel detection in the UPLC-MS/MS. In the method development, tap water matrix effects were examined and a solution for detection intensity suppression in the analysis of tap water samples was proposed. An addition of methanol into tap water samples could basically relieve the signal detection suppression by the real water matrix. This provides a detection method of these trace environmental pollutants with a linear range between 0.5 to 50 ng mL−1 and detection limits (LODs) (0.32–0.54 ng mL−1) without need of sample pre-concentration. This is a much simpler and faster method than gas chromatography-electron capture detection (GC-ECD) and gas chromatography-mass spectrometry (GC-MS), with comparable detection sensitivity.

Graphical abstract: Detection of phthalates in water using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry MRM mode– ‘ghost peaks’ and measurement methodology

Article information

Article type
Paper
Submitted
18 Aug 2010
Accepted
27 Oct 2010
First published
26 Nov 2010

Anal. Methods, 2011,3, 314-321

Detection of phthalates in water using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry MRM mode– ‘ghost peaks’ and measurement methodology

W. Li and J. Duan, Anal. Methods, 2011, 3, 314 DOI: 10.1039/C0AY00507J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements