Jump to main content
Jump to site search
SCHEDULED MAINTENANCE Close the message box

Maintenance work is planned for Monday 16 August 2021 from 07:00 to 23:59 (BST).

Website performance may be temporarily affected and you may not be able to access some PDFs or images. If this does happen, refreshing your web browser should resolve the issue. We apologise for any inconvenience this might cause and thank you for your patience.


Issue 1, 2014

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

Author affiliations

Abstract

Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane–isopropanol and ethyl acetate–ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample extracts could be related quantitatively to variations in the concentrations of the target analytes. Then, ATR spectra of the dried sample extracts were obtained and direct measurement of the spectra were carried out and modelled using partial least squares (PLS) and reference concentrations. PLS models obtained from the extracts of the two mixtures were compared with those obtained from direct measurement of sera samples. The prediction errors obtained using the proposed approach were considerably (between 27 and 72%) better than those obtained by the direct measurements of sera. For triglycerides and cholesterol relative errors below 9% and 12% respectively were obtained with this method, which are comparable to the tolerance for the errors of the control analysis established at the hospital. For HDL and LDL, the errors found were between 18 and 20%. The incorporation of a preprocessing extraction step, involves time and solvent consumption. However, the results obtained provide evidence that the proposed method provides, in a few minutes and using simple instrumentation and with minimum cost, important information about the lipidic profile of patients sera at a good screening confidence level.

Graphical abstract: Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

Supplementary files

Article information


Submitted
27 May 2013
Accepted
24 Oct 2013
First published
25 Oct 2013

Analyst, 2014,139, 170-178
Article type
Paper

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

D. Perez-Guaita, A. Sanchez-Illana, J. Ventura-Gayete, S. Garrigues and M. de la Guardia, Analyst, 2014, 139, 170 DOI: 10.1039/C3AN01057K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.


Social activity

Search articles by author

Spotlight

Advertisements