Issue 2, 2012

Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry

Abstract

The efficiencies of four different methods for the extraction of phospholipids (PLs) and lysophospholipids (LPLs) from human plasma samples were examined by comparing extraction recovery values using nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nLC-ESI-MS). For recovery measurements, six PL and six LPL standards of different head groups were spiked into a human plasma sample, and the peak areas of each individual species after extraction were measured from the chromatograms of the nLC-ESI-MS runs. Recovery was calculated by comparing the peak area of an extracted standard species with that of the same species' spike after extraction of the same plasma sample. For lipid extraction, four different extraction methods were examined: three based on the Folch method with different organic solvents such as CHCl3, methyl-tert-butyl ether (MTBE), and MTBE/CH3OH, and one relatively fast method involving CH3OH only. Evaluations of recovery showed that the modified Folch method with MTBE/CH3OH proposed in this study was effective for extracting most PL and LPL standards. Then, the four extraction methods were compared with the identified numbers of plasma PLs and LPLs, of which molecular structures can be confirmed by data-dependent, collision-induced dissociation experiments during nLC-ESI-MS-MS. These results demonstrated that the proposed method yielded the identification of 54 LPLs and 66 PLs from a plasma sample, which was the highest identification rate among the four methods.

Graphical abstract: Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
05 Oct 2011
Accepted
27 Oct 2011
First published
23 Nov 2011

Analyst, 2012,137, 451-458

Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry

S. K. Byeon, J. Y. Lee and M. H. Moon, Analyst, 2012, 137, 451 DOI: 10.1039/C1AN15920H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements