Issue 1197, 1975

Determination of aluminium in dental enamel by the carbon cup atomic-absorption method

Abstract

The possibility of using the carbon cup atomisation technique for the atomic-absorption determination of aluminium in dental enamel has been investigated. Various parameters that influence the sensitivity and accuracy of the measurements were studied by use of a standard electronic detection system (Varian AA-5; chart recorder f.s.d., 1 s) and oscilloscopic (Tektronix) recording of the absorption signal. The latter system enabled the atomic-and non-specific absorption signals to be studied as a function of the time of atomisation. Thus, increasing the rate of heating of the carbon cup in the atomisation step resulted in a substantial enhancement of the aluminium peak absorption signal. The presence of calcium in the solution (7·2 mg ml–1, in the form of the phosphate) produced a two-fold increase in sensitivity for aluminium.

For routine determinations of aluminium in tooth material (in vitro) 10 mg of finely ground and homogenised sample are dissolved in 6 N nitric acid and the solution is diluted to 0·5 ml; 5-µl aliquots are sampled for a single determination. A single calibration graph obtained by the standard addition method is adequate for one set of samples. No correction due to non-specific absorption is necessary, but the blank value (nitric acid) should be checked from time to time.

The absolute sensitivity of the method (3·5 × 10–11 g of aluminium) permits the determination of aluminium in tooth material both in vitro and in vivo at microgram per gram concentration levels with a general precision of 8 per cent.

In vivo analysis can be carried out on 300–600 µg of sample obtained by a chemical biopsy method. The main problem encountered in in vivo analysis lies in obtaining an aluminium-free support material for etching purposes. In addition, “clean room” facilities are recommended for improving the accuracy.

Article information

Article type
Paper

Analyst, 1975,100, 884-890

Determination of aluminium in dental enamel by the carbon cup atomic-absorption method

F. Dolinšek, J. Štupar and M. Špenko, Analyst, 1975, 100, 884 DOI: 10.1039/AN9750000884

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.